  1. Thread: rack superheat

    by jaybee
    Replies
    12
    Views
    620

    I read in the carlye lit. That on low temp...

    I read in the carlye lit. That on low temp applications they want and rtg temp from 35 to 50 deg. On 404a systems. Did not understand how that could be possible to maintain 30 sh. So i spoke with ...
  2. Thread: rack superheat

    by jaybee
    Replies
    12
    Views
    620

    this is what im thinking you probaly shoud go by...

    this is what im thinking you probaly shoud go by the return gas temperture reading of 35 to 50 degress.
  3. Thread: rack superheat

    by jaybee
    Replies
    12
    Views
    620

    rack superheat

    hi all,

    where is the best place to take a rack superheat ? this rack im working on has Carlyle 06d and 06e and the manufactor calls for RTG temperture to be between 35 to 50 degrees. if you are...
  4. I don't remember seeing any bolts. I hope there...

    I don't remember seeing any bolts. I hope there is , if so I would i just have to remove these bolts and place the defrost heater?
  5. what about the rear bottom baffle does that come...

    what about the rear bottom baffle does that come off ?
  6. rear defrost heaters on 2 dr hill phoenix case

    case model orz 2 is the model number . I have to change the rear defrost heater on this case , to those that have done this what is the best way to do this , do you have to take off the back walls of...
  7. Replies
    11
    Views
    758

    med temp rack off cycle defrost. when talking...

    med temp rack off cycle defrost. when talking about bypass I use a superhose from discharge to outlet side of the valve
  8. Replies
    11
    Views
    758

    gas logging in reciever

    having a problem with Hill phoenix rack, when it 90 degress and above the gas logs in the receiver. the liquid line psi is higher than the receiver psi. being that this is a receiver with one way in...
  9. Replies
    11
    Views
    805

    yes hot water reclaim 5 ft away

    yes hot water reclaim 5 ft away
  10. Replies
    11
    Views
    805

    Not asking what to do, have done already, Was...

    Not asking what to do, have done already, Was asking why opening the hold back valve with such low head allow me to get discharge back. I did forget to mention added more gas, but started to get...
  11. Replies
    11
    Views
    805

    rack head psi at 59 lbs

    arrived on site all fixtures warm no liquid in receiver one of 5 compressors running because if another one came on it would almost immeadiately reach suction target, anyway after fumbleling around...
  12. Replies
    1
    Views
    353

    direct connect to e2

    Hi everyone, Can anyone tell me how to step by step how to set my laptop up to direct connect to e2 ? on my old laptop it was set up for me y this controls guy and I used it once and never did it...
  13. Replies
    2
    Views
    554

    yes ,but that's what they want

    yes ,but that's what they want
  14. Replies
    2
    Views
    554

    b acurach hgm 400

    hi guys,
    they just install this in a bj's . Bj's set points are 5 ppm for a leak alarm with a 1 second delay. having a very hard time pinpointing this leak in the zone it is said to 'be in. I will...
  15. Replies
    6
    Views
    633

    so this is done without a router? and how do you...

    so this is done without a router? and how do you use team viewer only to control the computer that monitors the refrigeration.
  16. Replies
    6
    Views
    633

    I am not an energy management guy but enjoy...

    I am not an energy management guy but enjoy knowing all aspects of the game , basically I want to learn how this is done . oh I do have teamviewer install on my computer, so can you explain how I...
  17. Replies
    6
    Views
    633

    energy management

    I have not came across anyone doing this yet ,but would like to know how its done. A tech told me that he saw a guy doing start up work and he had his lab top hook up to the controller in the machine...
  18. Replies
    6
    Views
    522

    how do u determine if a condensor for the rack or...

    how do u determine if a condensor for the rack or reclaim is the proper size
  19. Replies
    6
    Views
    522

    heat reclaim fills up reciever

    hi all I was talking with a tech, and a very exspirenced one at that says he could not figure out this issue he had that in the summertime when the heat rec shut down the receiver fills up. don't...
  20. Replies
    4
    Views
    454

    not sure, looking for some lit to explain how...

    not sure, looking for some lit to explain how they suppose to work can u explain or guide me to where I could find some lit
  21. Replies
    4
    Views
    454

    yes but why would they pump out the condensor...

    yes but why would they pump out the condensor whenever the fans cycle off,not just when its in split
  22. Replies
    4
    Views
    454

    microchannel condencesor

    hi all , Just got a store that has these condensers on a zero zone rack. the racks are a,b,c all combined with 3 micro channel condersers,I was told that sections of the coils has valves that...
  23. Replies
    0
    Views
    221

    p445 oil control to sentronic 3

    just in case i had to change out the johnson oil control p445 to sentronic 3 will i put the 240 to240 on sentronics then use m1 and m2 as l and m and use the noa as the alarm circuit and cap the cma...
  24. Thread: comtrol 6k

    by jaybee
    Replies
    5
    Views
    468

    Do u have a contact number ???? Check your...

    Do u have a contact number ???? Check your private messages
  25. Thread: comtrol 6k

    by jaybee
    Replies
    5
    Views
    468

    do u have a contact number. Check your private...

    do u have a contact number. Check your private messages
  26. Thread: comtrol 6k

    by jaybee
    Replies
    5
    Views
    468

    . Yeah I know fred . He is just very busy with...

    . Yeah I know fred . He is just very busy with other projects , just don't like to bother him to much.
  27. Thread: comtrol 6k

    by jaybee
    Replies
    5
    Views
    468

    comtrol 6k

    where are u guys getting support now to work on 6ks. ie screen calibrations and dos commands needed to to work on theses units.Danfoss knowelge is very limited.Do anyone know anybody. Any replies are...
  28. Replies
    30
    Views
    3,809

    THANKS

    THANKS
  29. Replies
    11
    Views
    2,079

    So i guess if u have a pressure activated...

    So i guess if u have a pressure activated unloader there is no real way of knowing unless you remove the heads huh. Sorry
  30. Replies
    11
    Views
    2,079

    32 PLEASE NOTE THE LAST PARAGRAPH 2.4 — Service...

    32 PLEASE NOTE THE LAST PARAGRAPH
    2.4 — Service Procedures
    The service section covers replacement of valve plates
    and gaskets, service to the bearing head assembly
    containing the oil pump, and a...
  31. Replies
    11
    Views
    2,079

    CARLYLE O6E or any compressor with a pressure...

    CARLYLE O6E or any compressor with a pressure activated unloader
  32. Replies
    11
    Views
    2,079

    valve plate diagnosis

    Hello all,
    Just wondering how do u check to se if a valve plate is leaking with an pressure activated unloader and why wont the stardard way of checking will not work with psi activated unloaders?
  33. Thread: back up cpc

    by jaybee
    Replies
    5
    Views
    652

    Never done it before so i plugge into com see and...

    Never done it before so i plugge into com see and can u explain the rest of the steps ??
  34. Thread: back up cpc

    by jaybee
    Replies
    5
    Views
    652

    back up cpc

    hi everyone,
    Just took on five new stores with rmc's. The store is not useing and alarm box an d all com b are unplugged. I ask manger who monitors the store his response was "huh". They do refer...
  35. Replies
    2
    Views
    1,007

    5h40 5h60 carlyles

    Join Date: Apr 2003
    Location: New York
    Posts: 628

    Carlyle 5h40 and 5h60

    --------------------------------------------------------------------------------

    hi everyone,
  36. Replies
    31
    Views
    5,889

    Maybe that is why some of the fixtures are not...

    Maybe that is why some of the fixtures are not gettng proper defrost when the termination is set to thermostat. They terminate almost 10 sec after defrost is started. they could be the dig in that...
  37. Replies
    31
    Views
    5,889

    comtrol to e2

    im dealing with this conversion in one of the stores i service.For some reason the circuts that are set to thermostat to terminated defrost all terminate prematurely.Had to change to case temp or...
  38. Thread: NOP

    by jaybee
    Replies
    6
    Views
    595

    huh

    huh
  39. Thread: NOP

    by jaybee
    Replies
    6
    Views
    595

    regular rack ,copland compressor.he says he was...

    regular rack ,copland compressor.he says he was at the suction and pump discharge
  40. Thread: NOP

    by jaybee
    Replies
    6
    Views
    595

    NOP

    Just curious i had a fellow tech tell me that he had an 70# net oil psi. Today
    My response was did u calibrate your gauges?? And he was working on an rack system.Now , i think i remember some where...
  41. Thread: TXV pressure

    by jaybee
    Replies
    17
    Views
    2,503

    huh

    huh
  42. Replies
    25
    Views
    2,216

    hmm

    hmm
  43. Replies
    4
    Views
    612

    :bump: The oat is in the hvac...

    :bump:

    The oat is in the hvac controller,bd9-pt3 and the controller that has the oat to lock out the exhuast fans at 32 degress are bd 17.1 ,but when i go to the 6k in the 17.1 input is not...
  44. Replies
    4
    Views
    612

    Comtrol - global inputs

    Hi all ,

    When assigning global inputs for a task i.e., exhaust fan motor to lock out at 32 degress (oat).should I assign it, say board 17.1 in the 6k and do i have to do a transfer ai task??? Do...
  45. Thread: oil failure

    by jaybee
    Replies
    13
    Views
    1,706

    Yes Thats what i mean by switching the leads. Ive...

    Yes Thats what i mean by switching the leads. Ive got and oil pump on my truck ready to go when the call comes. Nobody messes with my ot.
  46. Thread: oil failure

    by jaybee
    Replies
    13
    Views
    1,706

    What is the likely hood???? Ha, ha, ha,. Sorry,...

    What is the likely hood???? Ha, ha, ha,. Sorry, fellows inside joke.All useal suspects have been checked and if faulty corrected. I just said the h*** with and corrected the unloader situations by...
  47. Thread: oil failure

    by jaybee
    Replies
    13
    Views
    1,706

    Would this also apply on an rack system ?

    Would this also apply on an rack system ?
  48. Thread: oil failure

    by jaybee
    Replies
    13
    Views
    1,706

    oil failure

    I read in an old post that if a compressor is always running unloaded continuesly if could cause an oil failure?? If so can anyone explain.
  49. Replies
    44
    Views
    5,008

    How could staying unloaded cause an oil failrue?

    How could staying unloaded cause an oil failrue?
  50. horizontal receiver, replace gauge rack system

    Hi all,
    At some point i am going to have to change a faulty gauge on a receiver.
    I figure i am going to store all the gas i can in the condensor by closeing off the drop leg , then isolate the...