  1. that very small amount of air leakage is nothing...

    that very small amount of air leakage is nothing to worry about
  2. a service tech with a meter will be able to sort...

    a service tech with a meter will be able to sort it out , at least you dont have to wait all day for it to quit.
    you got a extra year out it
  3. did you pay to transfer the warranty. sounds...

    did you pay to transfer the warranty.
    sounds like he pulled out the expansion valve and installed a piston .
    due to the failure rate of txv's probably did you a favor
  4. Replies
    18
    Views
    347

    contactors need replaced if they look worn out or...

    contactors need replaced if they look worn out or have voltage drop ,beside much cheaper than a compressor
  5. has anybody capped the drain line outside the...

    has anybody capped the drain line outside the unit and filled the drain pan with water to see if it is cracked , or bring a big peice of plexiglass to cover the opening and run the unit to see what...
  6. A savy tech could make it work ,sounds like you...

    A savy tech could make it work ,sounds like you may have found one ,maybe you misunderstood the airflow
  7. Have your contractor show you the seer and hspf ...

    Have your contractor show you the seer and hspf difference of the 2 airhandlers
  8. Does the evap coil have a txv to meter the...

    Does the evap coil have a txv to meter the refrigerant
  9. Did the old one look like the points were burned

    Did the old one look like the points were burned
  10. i agree

    i agree
  11. is the insulation in the unit wet , if so the...

    is the insulation in the unit wet , if so the unit will condensate
  12. i think your on the right track ,any worth while...

    i think your on the right track ,any worth while tech will have a contactor on his truck
  13. the new trane heat pumps there is no x14i the...

    the new trane heat pumps there is no x14i the only 14 is a xr14 and the 16 s either a xr16 or a xl16i and they are not 2 stage to get 2 stage it is either a xr17 or xl18i
    the new units are 37w x34d
  14. its best to have 24 inches between the units . ...

    its best to have 24 inches between the units .
    how tall is the wall
  15. Replies
    3
    Views
    255

    that little grey thing that looks burned ,thats...

    that little grey thing that looks burned ,thats normal it is a heat disipating resistor
  16. Replies
    6
    Views
    445

    if you truly had 22 degrees of sub cool and 48...

    if you truly had 22 degrees of sub cool and 48 degrees of super heat your txv was not working right what was the final numbers after adding refrigerant
  17. it des not appear to need a trap

    it des not appear to need a trap
  18. http://securenet.goodmanmfg.com/Toolkit/LongsetGui...

    http://securenet.goodmanmfg.com/Toolkit/LongsetGuideLines/R-410A%20Long%20Line-set%20Application%20for%20Goodman%20Condenser%20Application.pdf
  19. Replies
    7
    Views
    367

    if he installed 9 lbs of refrigerant the system...

    if he installed 9 lbs of refrigerant the system was probably empty. is the unit cooling ok because if you mix refrigerants they do not cool properly
  20. there is not a closer place to put the outdoor...

    there is not a closer place to put the outdoor unit
  21. Replies
    6
    Views
    357

    i would go with a 2 ton 2 speed unit , the Trane...

    i would go with a 2 ton 2 speed unit , the Trane xl18i would be a good unit also the carrier infinity would be a good choice .
  22. Replies
    4
    Views
    346

    might as well replace it now. also trane has...

    might as well replace it now. also trane has discontiued the 20i 2 compressor system
  23. sounds like the duct work is the issue

    sounds like the duct work is the issue
  24. Replies
    19
    Views
    741

    only a total hack would do somthing so stupid

    only a total hack would do somthing so stupid
  25. the company does not have to be a carrier dealer...

    the company does not have to be a carrier dealer to repair it or warranty parts ,im not conviced the unit is defective beyond repair .
  26. Replies
    11
    Views
    421

    do not expect aluminum coils to be the savior ,...

    do not expect aluminum coils to be the savior , we have been replacing them also for leaking
  27. on warranty capacitors we use after market ,also...

    on warranty capacitors we use after market ,also there is not a big price difference between part warranty and non part warranty .
    fyi the 19i has a ecm condenser fan motor no run cap required
  28. Replies
    13
    Views
    443

    At that price i would put a compressor in it....

    At that price i would put a compressor in it. although does the price include the return trip to remove the suction drier replace the biflow drier and refill it with new refrigerant .
  29. Replies
    6
    Views
    1,197

    hope you did not downgrade to a larger unit

    hope you did not downgrade to a larger unit
  30. Replies
    12
    Views
    455

    highly unlikely that you are flwing 1800 cfm as...

    highly unlikely that you are flwing 1800 cfm as most 5 ton units the duct system is severly undersized what size are your filters .
    if you are going to replace the outdoor unit i would put a new...
  31. Replies
    12
    Views
    455

    just have the thermal expansion valve replaced as...

    just have the thermal expansion valve replaced as that is what appears to be the problem
  32. r22 is 10.10 lbs per gallon should only need a...

    r22 is 10.10 lbs per gallon should only need a quart
  33. Replies
    12
    Views
    455

    that 42 psi is a huge issue does the evap coil...

    that 42 psi is a huge issue does the evap coil have a expansion valve or piston to meter the refrigerant .might want to call the people that replaced the expander coil
  34. more than likly its wired wrong at the thermostat

    more than likly its wired wrong at the thermostat
  35. time for a new unit

    time for a new unit
  36. a service call would have been a good place to...

    a service call would have been a good place to start ,yes a bad capacitor could have caused the whole problem
  37. Replies
    12
    Views
    418

    this tech you speak of does he have his own...

    this tech you speak of does he have his own business .
    its possible that the other unit did not work well for many reasons other than being to small ,and if it was due to the ducts being to small...
  38. if you dont have a furnace to support 16 seer you...

    if you dont have a furnace to support 16 seer you wont get 16 seer anyway.
    i would go with the Trane
  39. Replies
    12
    Views
    418

    probably freezing up due to lack of air flow .

    probably freezing up due to lack of air flow .
  40. Replies
    12
    Views
    281

    im curios as to why there was a air leak after a...

    im curios as to why there was a air leak after a complete duct seal
  41. You already have cheap now get a contractor to...

    You already have cheap now get a contractor to rehab you complete duct system to flow the proper air
  42. Get a xv furnace

    Get a xv furnace
  43. Replies
    8
    Views
    358

    A ice chest full of cold drinks and some pizza...

    A ice chest full of cold drinks and some pizza for lunch and a restroom for them to use will go a long way
  44. Your tech is full of crap the size of unit and...

    Your tech is full of crap the size of unit and the size of house have no bearing on the pressure .is it a heat pump or gas furnace
  45. Are you getting a new evaporator coil also

    Are you getting a new evaporator coil also
  46. Replies
    8
    Views
    334

    Not sure how old it is ,bet the new dose not last...

    Not sure how old it is ,bet the new dose not last as long :.02:
  47. Replies
    11
    Views
    511

    Might be better off replacing the whole thing and...

    Might be better off replacing the whole thing and get a high efficient furnace with a ecm motor then you could get 17- 18 seer .
  48. Replies
    8
    Views
    377

    I would suspect the start kit .although it could...

    I would suspect the start kit .although it could be several other things
  49. Where does the drain exit , if outside no trap is...

    Where does the drain exit , if outside no trap is needed
  50. Replies
    6
    Views
    333

    Does it have a txv or a piston

    Does it have a txv or a piston