  1. Replies
    6
    Views
    415

    a heat pumps discharge temp could be at skin temp...

    a heat pumps discharge temp could be at skin temp ( 98.6 ) or just a touch below at times, giving the impression that they are not heating, the air is warm enough to heat the home just not warm...
  2. not sure the origin of it, as im not the...

    not sure the origin of it, as im not the original installer, just the only one around that was even willing to repair it, it was on a daycares afterschool building, so it wasn't a problem that it...
  3. dont know about their mini splits, but I had a 5...

    dont know about their mini splits, but I had a 5 ton split system that has mini split type controls and a weird little outdoor fan motor on it. had to replace the condenser fan motor took over 6...
  4. Replies
    10
    Views
    901

    something is adding heat to your supply air, ...

    something is adding heat to your supply air, *Hint hint* Cant get technical in the open forums though, maybe a mod will happen along this and move over to tech to tech where a little more info...
  5. Replies
    5
    Views
    396

    just gut the panel, run a new stat wire, and...

    just gut the panel, run a new stat wire, and make it run like a normal one ive done that when I run into this, though just a standard double pole single throw relay will work, cant remember the...
  6. Replies
    5
    Views
    396

    is this an old coleman with the switches on the...

    is this an old coleman with the switches on the front panel of the furnace. if so there are fan relays in the control box that control the a/c it uses a heat only tstat and the relays to...
  7. Replies
    3
    Views
    416

    the cb 27 coupled with the dehum relays will also...

    the cb 27 coupled with the dehum relays will also serve you well, that is what I install in Ms and have had great results
  8. Replies
    4
    Views
    481

    Weird plumbing issue.

    I'll start off by saying that I in no way claim to be a plumber or know anything about it, but I took a call today from the wife of a disabled vet. They had been without Hot water since the water...
  9. you will need SMALLER orifices to run lp, most...

    you will need SMALLER orifices to run lp, most mfg make conversions kits, I WOULD NOT go it alone, way too much liability for you to try to make a kit for it your self, if the job goes south, and...
  10. wish I could take credit for the penny drywall...

    wish I could take credit for the penny drywall test, not my idea though, one of the drywall mfg came up with that easy way to test it
  11. drywall can do it, well water with a high sulfur...

    drywall can do it, well water with a high sulfur content, fertilizers/pesticides from nearby fields. there is a lab that you can send air samples to and they will tell you exactly whats in it. ...
  12. you really need to have an indoor air quality...

    you really need to have an indoor air quality analysis done. good possibility that there is something in the air of your home that is eating the coils. I had a customer that was having the same...
  13. there is an interface module that will make the...

    there is an interface module that will make the icomfort work with the g71 you wont have all the diagnostics that the icomfort offers but will give you all the control of the stat from remote...
  14. Replies
    17
    Views
    1,212

    we have taken over the warranties for a few...

    we have taken over the warranties for a few dealers that lennox axed due to installation standards not being up help, as far as sales quotas ive never had anyone say anything about us meeting or...
  15. Replies
    17
    Views
    1,212

    A "Dave Lennox Premier Dealer" has to go thru...

    A "Dave Lennox Premier Dealer" has to go thru more to become that status of a dealer. The factory stays in close contact with the dealers customers, asking questions to insure that the dealer is...
  16. Replies
    8
    Views
    739

    since its isn't a "dedicated" supply(as in its...

    since its isn't a "dedicated" supply(as in its brought to the site and stored) and has to be pressure regulated there, more regulators and such to break down, more prone to moisture issues due to...
  17. Replies
    3
    Views
    305

    I believe there is a temp thermistor on the...

    I believe there is a temp thermistor on the outdoor unit that sends that info back to the stat, you do have to have 4 wire to the tstat and the outdoor unit, I do know that it will use the...
  18. Replies
    3
    Views
    305

    as long as its 4 wire and 18 gauge, it shouldn't...

    as long as its 4 wire and 18 gauge, it shouldn't be a problem
  19. ive worked on a bunch of these machines, found...

    ive worked on a bunch of these machines, found the same thing each time, the screen before the orfice plugged with a white plastic shaving like substance,
  20. Replies
    2
    Views
    361

    so thats how they are able to say so many...

    so thats how they are able to say so many millions are signing up, you dupilcate each person that actually gets on to do anything.

    something else comes to mind, Ive been doing some thinking...
  21. Replies
    2
    Views
    361

    the gubment healthcare website

    So out of morbid curiosity, and the inability to sleep tonight, i went to healthcare dot gov and it let me on, so i started the app process (about a 3hr process) just to see what it offered, that...
  22. Replies
    14
    Views
    1,720

    its the complete system that will rate out, ...

    its the complete system that will rate out, furnace, coil and outdoor unit, make sure the ahri sheet has the model numbers of all your equipment on it, they yellow sticker is the most common...
  23. Replies
    11
    Views
    650

    it can be done, I have done it in the past, ...

    it can be done, I have done it in the past, make sure that the blower in the unit is rated for the btu output of the pump though, most MH air handlers will only have a 1200/1400 cfm blower...
  24. Replies
    3
    Views
    829

    should be an edit post link on the bottom of your...

    should be an edit post link on the bottom of your post beside the reply tab, if not, you can click on the triangle with exclamation point in it and that will flag your post and you can explain to...
  25. Replies
    3
    Views
    829

    First and foremost you will need to edit out the...

    First and foremost you will need to edit out the prices from your post, as they are a violation of the site rules,

    Second, I have never heard of that particular brand (napoleon) but I am south...
  26. Replies
    4
    Views
    547

    contact the testing agency you got it thru, give...

    contact the testing agency you got it thru, give them your social number and they will replace it, rses cost 10 for a replacemtn card , esco was 10 or 15 when i replaced mine
  27. emails offering assitance are also frowned upon, ...

    emails offering assitance are also frowned upon, one of the reasons is liablity, if i offer a suggestion, you electrocute your self and die while attempting the site owners and myself could be...
  28. i will ask though, did you or anyone else...

    i will ask though, did you or anyone else weed-eat the grass around the outdoor unit in the last few days or do you have a teething pup in the yard?
  29. its gonna be one of a couple of problems, sadly...

    its gonna be one of a couple of problems, sadly due to the no DYI rules of the site i highly doubt if anyone will tell you what they are or how to repair it, i can say though that it should be a...
  30. Replies
    7
    Views
    471

    there could also be a drain safety switch in the...

    there could also be a drain safety switch in the condensate pan or line that would shut it down that breaks power to the stat, the unit is powered but the stat isnt, sounds like a safety is...
  31. Replies
    0
    Views
    292

    welfare abuse

    I sent this email a few minutes ago to my congressional delegation, probably wont do any good but if felt good to vent:

    Mississippi Delagation:

    While in a local discount store earlier today i...
  32. Replies
    7
    Views
    471

    sounds as if the stat has went south on you, ...

    sounds as if the stat has went south on you, the light in the unit is telling you that the system has hi and low voltage, the only thing i would really reccomend is turning the power of to the...
  33. Replies
    8
    Views
    662

    it takes a 25 370 for the compressor, a 5 370...

    it takes a 25 370 for the compressor, a 5 370 for the fan it shows a part number for a 25/5 370 it its a dual and if it has a start cap with a potential relay it takes 145-175 330vac for the start
  34. Replies
    34
    Views
    2,864

    the system may just need tweaking, I would give...

    the system may just need tweaking, I would give them a call and give them a chance to make it right before placing a stop on the check, it could be something very simple that was over looked, if...
  35. Replies
    3
    Views
    429

    i talked with someone at fieldpiece about an hour...

    i talked with someone at fieldpiece about an hour ago, and they fixed me right up, FIELDPIECE IS NUMBER ONE IN CUSTOMER SERVICE, in my opinion
  36. Replies
    3
    Views
    429

    !!!HEY FIELDPIECE DUDE!!!!!

    I cant remember the fieldpiece guys user name, but I am needing a battery cover and screw for my sc76, could anyone help me get in touch with him so I can get a part number for it so I can order one...
  37. Replies
    7
    Views
    664

    i tried one time, never could get it to stick or...

    i tried one time, never could get it to stick or seal, ended up ordering a new king valve and replacing it and the part of the line set attached to it,
  38. Replies
    7
    Views
    664

    cut it out and redo with the right stuff, i dont...

    cut it out and redo with the right stuff, i dont think the right stuff will stick to soft solder with out problems down the road, why if i may ask did your friend use soft solder, or hire a hack...
  39. Replies
    6
    Views
    541

    ive used it when brazing copper used for gas...

    ive used it when brazing copper used for gas lines, never used it for refrigeration piping though, from my experiance with gas it works good, and you can use just an acetelene tank and air to get...
  40. I bet the judges really regret not selecting me...

    I bet the judges really regret not selecting me now, even though i cant sing, they all want me on thier team about right now! Sounds like a spin off of the show, "The Voice A/C edition" a bunch of...
  41. I think this song sums up how most of us feel ...

    I think this song sums up how most of us feel

    http://youtu.be/gngvwygsZDg
  42. we already pay federal income tax and state...

    we already pay federal income tax and state income tax on all the profits made, I have to pay a yearly inventory tax on the product in the store, and heaven forbid we have a good year I have to pay...
  43. you will have to go to the ahri website, enter...

    you will have to go to the ahri website, enter your model numbers of the indoor coil/air handler and outdoor unit, and then search the match up, there are so many approved matches that the it would...
  44. I am totally against it, they say it will...

    I am totally against it, they say it will protect "brick and mortar stores". well my mom has a store, and instore sales are around $500 monthly where her internet sales run over $16k a month, so...
  45. Replies
    6
    Views
    1,932

    I just re-read your post, I miss read it the...

    I just re-read your post, I miss read it the first time, I see that you aren't in the states, so im not sure on the warranty but with it being less than 3 years old it should still have warranty...
  46. Replies
    6
    Views
    1,932

    that is a signature series lennox, it comes out...

    that is a signature series lennox, it comes out of the box with a 10 yr warranty on the parts, all you are responsible for is the diagnostic and the labor to repair, if it shut down on a critical...
  47. Replies
    13
    Views
    978

    where are you taking the test at, when I signed...

    where are you taking the test at, when I signed up to take it there was a list of things to bring with you, non-programable calculator, it was on the page that listed the approved reference...
  48. Replies
    13
    Views
    978

    yeah, he still talks about riding with you on...

    yeah, he still talks about riding with you on the round-about at the airport, get your post count up to 15 and apply for a pro membership, there is a wealth of knowledge on the other side once...
  49. Replies
    13
    Views
    978

    you will need a calculator, and all the formulas...

    you will need a calculator, and all the formulas you need are in the book,

    what part of ms are you in, from your user name, me thinks me already know who you be!
  50. Replies
    13
    Views
    978

    the test I took was in depth and math heavy, ...

    the test I took was in depth and math heavy, lots of calculations, it also contained a lot about oil furnaces( which we have none in my area,) the test was open book, it gave me the impression...
Results 1 to 50 of 384
Page 1 of 8 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event