Search:
Type: Posts; User: Ctl-fool
Search: Search took 0.01 seconds.
-
01-31-2013, 03:45 PM
- Replies
- 5
- Views
- 356
You should have a VAV calibrate schedule that I...
You should have a VAV calibrate schedule that I believe opens and closes the air valve and water valve during this recalibration.
I'm pretty sure the calibration drives both valves closed and then... -
01-29-2013, 05:20 PM
- Replies
- 5
- Views
- 356
Trane Tracer Summit VAV II/III UCM Reheat Valve Water Flush
Does anyone know of an easy way to globally force Trane VAV UCMs on a summit network to drive all the reheat valves open? I know there is a check box setting on one of the UCM tab pages in UCM...
-
03-13-2012, 11:30 AM
Thread: Insight PPCL Editor PDF
by Ctl-fool- Replies
- 13
- Views
- 1,774
Any chance I could get the apogee insight users...
Any chance I could get the apogee insight users manual? email is in profile.
would greatly appreciate it.:angel: -
01-17-2012, 10:51 PM
Thread: Johnson Controls N2 Problems
by Ctl-fool- Replies
- 13
- Views
- 985
any 0-10v inputs on this controller? Heard of...
any 0-10v inputs on this controller? Heard of ahu controllers resetting if the input goes over the 10vdc limit.
-
11-09-2011, 08:40 AM
Thread: Panoptix by JCI
by Ctl-fool- Replies
- 22
- Views
- 2,020
Anyone seen anything new on this? Hardware...
Anyone seen anything new on this? Hardware components/IT requirements/interfaces for 3rd parties?
:bump: -
09-29-2011, 08:01 AM
Thread: Three wire FX MSTP to two wire Jace
by Ctl-fool- Replies
- 13
- Views
- 1,232
Just wire +/- to +/-. I think Ive done that for...
Just wire +/- to +/-. I think Ive done that for an FX60 once and it worked.:putergreet:
-
09-15-2011, 10:11 PM
Thread: WebCtrl Vs I-vu?
by Ctl-fool- Replies
- 5
- Views
- 663
Interesting....id suspect that there has to be...
Interesting....id suspect that there has to be some software separation that differentiates webctrl from i-vu. I cant imagine that they would allow for ALC ifos/branches and Ivu dealers to go...
-
09-15-2011, 06:25 PM
Thread: WebCtrl Vs I-vu?
by Ctl-fool- Replies
- 5
- Views
- 663
WebCtrl Vs I-vu?
Anyone familiar enough with both to say what the main differences are? I-vu speaks CCN for the legacy controllers, and Bacnet with the Open controllers, the pretty much look like the ALC stuff...
-
08-23-2011, 09:13 PM
Thread: Older ALC CMnet Portal
by Ctl-fool- Replies
- 0
- Views
- 336
Older ALC CMnet Portal
Am looking for an older piece of ALC equipment to do CMnet to Bacnet, the Portal module which used the older exec 4 or exec 6 firmware.
Anyone have one of these lying around? -
08-14-2011, 09:34 PM
- Replies
- 13
- Views
- 1,534
too bad....RZ had an interesting product, with...
too bad....RZ had an interesting product, with alot of 3rd party drivers for legacy integration.
-
08-14-2011, 06:33 PM
- Replies
- 13
- Views
- 1,534
So, this is the death of Richards-zeta/cisco, or...
So, this is the death of Richards-zeta/cisco, or will RZ be spun back off into a seperate company?
-
06-10-2011, 08:31 AM
Thread: Trane VAV I protocol gateway
by Ctl-fool- Replies
- 4
- Views
- 380
Yup, I know we could keep the bmtw to use as a...
Yup, I know we could keep the bmtw to use as a gateway, just looking at options should we want to take the bcu out. currently the bcu has 1 comm2 (red) for centravac, 1comm3(red) for VAVI, 1comm3...
-
06-09-2011, 09:36 PM
Thread: Trane VAV I protocol gateway
by Ctl-fool- Replies
- 4
- Views
- 380
Trane VAV I protocol gateway
Anyone know of a prtocol gateway available for the old Trave VAVI ucm's
-
06-08-2011, 04:49 PM
Thread: analog output to analog input short
by Ctl-fool- Replies
- 2
- Views
- 300
analog output to analog input short
Here was an interesting situation I ran into recently:
ALC module (ME Controller) using its 0-10vdc analog output to another ALC (OEM I/O Zone controller) analog input set at 0-5v at In1. Both... -
05-24-2011, 04:19 PM
Thread: Trane's Tracer SC
by Ctl-fool- Replies
- 19
- Views
- 4,037
Any new reviews on this yet? How does it compare...
Any new reviews on this yet? How does it compare with Ax or Struxureware?
-
05-18-2011, 09:37 PM
Thread: non-JCI workbench for FX-60
by Ctl-fool- Replies
- 4
- Views
- 405
non-JCI workbench for FX-60
anyone know if a non-jci workbench laptop will work on an FX-60?
-
05-16-2011, 03:13 PM
Thread: Free BAS Graphics Visio Stencils
by Ctl-fool- Replies
- 15
- Views
- 10,560
this file still avail? Cant find it on the site...
this file still avail? Cant find it on the site - anyone have it?
-
05-13-2011, 04:06 PM
Thread: Eclypse Problock
by Ctl-fool- Replies
- 18
- Views
- 2,188
any hint on the "secret code" thingy?:censored:
any hint on the "secret code" thingy?:censored:
-
05-05-2011, 05:27 PM
Thread: Need Help - Staefa Actuator
by Ctl-fool- Replies
- 9
- Views
- 1,332
I am pretty sure that Belimo still makes an...
I am pretty sure that Belimo still makes an actuator that has a 0-20 phase cut signal. Simplest would be to just use the phase cut signal as is and wire same.
Or you could just change out the... -
04-04-2011, 08:04 AM
Thread: using ur laptop as jace/unc
by Ctl-fool- Replies
- 20
- Views
- 1,649
Since he referred to a "UNC" instead of an ENC, I...
Since he referred to a "UNC" instead of an ENC, I think he may be referring to R2, not Ax (Schneider/TAC):.02:. I think it still can be done, though.
-
03-18-2011, 07:30 PM
Thread: Johnson Controls DX-9100
by Ctl-fool- Replies
- 49
- Views
- 5,014
Have a site with the following: 1 DX with Xt,...
Have a site with the following:
1 DX with Xt, 1 AHU01, and 1 UNT. Could your new device work with these?
Any chance you could send me a beta module to try out?
:grin2: -
03-18-2011, 07:27 PM
Thread: Old trane tracer system.
by Ctl-fool- Replies
- 7
- Views
- 1,181
Found this on the web. Hope it helps. ...
Found this on the web. Hope it helps.
:putergreet:
https://www.comfortsite.com/Resources/Literature/pdf/STZ37L4VBWR.pdf -
02-28-2011, 08:43 AM
Thread: Johnson Controls DX-9100
by Ctl-fool- Replies
- 49
- Views
- 5,014
Um... you have any more details on the N2...
Um... you have any more details on the N2 webserver? Is this a niagara based product? Id like some info if possible.
-
02-25-2011, 08:10 AM
Thread: Tridium web interface R-2
by Ctl-fool- Replies
- 7
- Views
- 1,030
try changing the screen display settings in...
try changing the screen display settings in Control Panel. try settings of 1024x768 or 1152x864 if your monitor will support it.
-
01-18-2011, 08:14 AM
Thread: ABCS Conf in Orlando
by Ctl-fool- Replies
- 23
- Views
- 1,809
and the enhanced functionality of being able to...
and the enhanced functionality of being able to program these controllers through a JACE
....wow, that was the one major thing that limited using FEC's without NAE/NCE.
Now a big question...
Results 1 to 25 of 145