Search:

Type: Posts; User: jimmyed

Page 1 of 15 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    14
    Views
    1,373

    Case and all. insulation in the other case...

    Case and all. insulation in the other case pretty much seals it up all the way around. I slipped some foam tape on one, as well as on the bottom of the coil case. A little more on the door and no...
  2. Replies
    14
    Views
    1,373

    2nd one had to use a threaded 9- right out off...

    2nd one had to use a threaded 9- right out off the coil. across top of furnace, around to the back and across the back into the pump.
  3. Replies
    4
    Views
    617

    Nice, I put a base under anything 3 tons or more,...

    Nice, I put a base under anything 3 tons or more, pull from side and bottom. Only thing I don't like is the flues out the top, can't they come out the side?
  4. Replies
    8
    Views
    1,189

    and those pressure switches are sensitive!

    and those pressure switches are sensitive!
  5. Replies
    14
    Views
    1,373

    I've been hacking things up across town

    Done a few coil and ac swaps lately.

    https://c4.staticflickr.com/4/3691/18685310079_f3c2e5cb09_h.jpg

    https://c2.staticflickr.com/6/5514/18657538890_f99f3d387d_h.jpg

    Just slip them in case...
  6. Replies
    8
    Views
    1,189

    Looks good, drain should have been done different...

    Looks good, drain should have been done different but other than that, top notch! Supposed to be an air gap between coil drain and furnace drain.
  7. Thread: XV20i

    by jimmyed
    Replies
    13
    Views
    1,077

    :) My only complaint would be the eac. Can't...

    :) My only complaint would be the eac. Can't believe anyone still sells them. People around here always threw the guts out and put in a regular filter. I haven't been to one house with an eac...
  8. Replies
    6
    Views
    1,149

    pipe my drain like how? its open, do them all...

    pipe my drain like how? its open, do them all this way and haven't had a problem yet. 1/2" cpvc slid inside 3/4 sh120
    open tee is so that in the event that the trap clogs up in the winter i don't...
  9. Replies
    6
    Views
    1,149

    Another easy one

    https://c1.staticflickr.com/1/271/17737838604_8ee4b8a802_h.jpg

    https://c4.staticflickr.com/8/7733/18334023486_6ff2e56eb9_h.jpg

    https://c4.staticflickr.com/8/7753/18174291129_9325e82942_h.jpg
    ...
  10. Replies
    11
    Views
    1,188

    Another low boy gone.

    https://c4.staticflickr.com/8/7754/18253362776_1b84acea36_h.jpg
    https://c4.staticflickr.com/8/7752/18093585259_0fecc8b326_h.jpg

    Flues look like ass.. Not much else I could do. Been a busy ass...
  11. Replies
    8
    Views
    750

    Yeah I don't know if they put this in or not. ...

    Yeah I don't know if they put this in or not. Probably did. Basement was a dump. 50yr old guy still living with his mom.
  12. Replies
    8
    Views
    750

    Thank ya sir.

    Thank ya sir.
  13. Replies
    8
    Views
    750

    Total electric in a basement

    This job sucked. Crowded basement. Had to change plenum and takeoffs so I would have enough height for the fan coil. Had 3 trunk runs out of the plenum...

    ...
  14. Replies
    20
    Views
    2,980

    https://c4.staticflickr.com/8/7781/17659185703_8ea...

    https://c4.staticflickr.com/8/7781/17659185703_8ea1c0e93b_h.jpg we found quite a few this year
  15. Replies
    6
    Views
    1,055

    Why would you not use a cased coil?

    Why would you not use a cased coil?
  16. I wish you all would quit dogging on my work,...

    I wish you all would quit dogging on my work, jeez!
  17. Replies
    13
    Views
    1,490

    We haven't sold any, we aren't quick to jump on...

    We haven't sold any, we aren't quick to jump on the new equipment bandwagon. Know 2 dealers that sold several. Every one they sold they took out and put in the 2 stage heat pumps. One dealer has...
  18. Replies
    13
    Views
    1,490

    Skip the greenspeed and go with the 17 or 19 seer...

    Skip the greenspeed and go with the 17 or 19 seer heat pumps. Too many issues with greenspeed units.
  19. Replies
    13
    Views
    1,673

    Foam tape. Yes 3 pieces, Transition, filter box,...

    Foam tape. Yes 3 pieces, Transition, filter box, and plenum. This one actually had 16" flex thru the ceiling. I just put foam tape between each piece and screw them together. We don't use...
  20. Replies
    10
    Views
    1,998

    Infinity/evolution is simple. All 4 wires from...

    Infinity/evolution is simple. All 4 wires from the indoor unit, outdoor unit, all the thermostats, go to the same terminals. So in the zone board you have a G, Y, W, R set of wires, then your 2+...
  21. Replies
    16
    Views
    1,889

    Yellow jacket one.

    Yellow jacket one.
  22. Replies
    20
    Views
    2,980

    Ok heres the deal, yeah it will go all over the...

    Ok heres the deal, yeah it will go all over the floor. Then the homeowner will see it. The thing is we don't really have many if any drain issues. Media filters, no dirt on the coil no dirt in the...
  23. Replies
    10
    Views
    1,998

    Zoning made complicated... Infinity/evolution....

    Zoning made complicated...

    Infinity/evolution. Makes life simple. Best there is as far as zoning goes.
  24. Replies
    20
    Views
    2,980

    Circus I freeze them, basically get them ready to...

    Circus I freeze them, basically get them ready to fry and toss them in freezer, vacuum seal the next day.

    No purple primer here, it looks like crap.

    Trap is just something to plug up, no need.
  25. Replies
    20
    Views
    2,980

    I cooked about half and froze the rest for a...

    I cooked about half and froze the rest for a later date. Drip leg in the crawl, and customer was persistent that it didn't need one, he only worked for the gas company for 40 years. Yes there is a...
  26. Replies
    20
    Views
    2,980

    https://farm8.staticflickr.com/7700/16631766814_f7...

    https://farm8.staticflickr.com/7700/16631766814_f7c5f13d29_h.jpg

    some from earlier this week.
  27. Replies
    20
    Views
    2,980

    I'm going to call this one obnoxious piping.

    https://farm9.staticflickr.com/8693/17065969788_7fc7cfd0e5_h.jpg

    Just one of those jobs. Infinity modulating furnace and 2 stage ac.

    Started the day with swmbo wrecking her car, got a 2 hour...
  28. Replies
    13
    Views
    1,673

    Foil tape is on the truck. Yeah I hate them...

    Foil tape is on the truck.


    Yeah I hate them sitting on the floor, gotta stand on your head to work on them. Not to mention getting the door off is a pain.
  29. Replies
    16
    Views
    1,889

    24ga base yes, everything else 26ga. We...

    24ga base yes, everything else 26ga.

    We utilize a fold in on a lot of those pieces, specifically the filter connections. The filter box has a 1 1/2" flange so we just use a 1 1/2" fold in. Foam...
  30. Replies
    16
    Views
    1,889

    Another total electric

    Put in an Infinity system on this one. Weird return up the back. Everything has duct liner in it, in a garage
    https://farm8.staticflickr.com/7682/17239740695_031a7ad3e2_h.jpg
    ...
  31. Replies
    13
    Views
    1,673

    Total Electric changeout.

    https://farm8.staticflickr.com/7654/17041605260_c32e471e53_h.jpg
    https://farm6.staticflickr.com/5464/16606706284_b838ec55a4_h.jpg
    https://farm8.staticflickr.com/7701/16608941423_fd2b149e52_h.jpg...
  32. Replies
    13
    Views
    1,473

    With as many leaky coils as I see, this is...

    With as many leaky coils as I see, this is completely wrong lol.

    Use media filters, its like a nice job but you forgot a step.. Looks pretty good otherwise.
  33. Thread: New 92%er

    by jimmyed
    Replies
    17
    Views
    2,330

    Looks a lot better than most, Wheres all the foil...

    Looks a lot better than most, Wheres all the foil tape?!?!
  34. Replies
    26
    Views
    2,829

    Man what a design flaw.

    Man what a design flaw.
  35. Thread: New 92%er

    by jimmyed
    Replies
    17
    Views
    2,330

    Why the pressure fitting in the flue? Don't you...

    Why the pressure fitting in the flue? Don't you normally try to get the intake outside as well?
  36. Replies
    26
    Views
    2,829

    Only option to run flues in front of coil?

    Only option to run flues in front of coil?
  37. Replies
    58
    Views
    4,711

    You will never make it charging what you do. We...

    You will never make it charging what you do. We are far from what the big companies prices but we aren't doing **** for free. We're also not getting rich. You're not going to be around for warranty...
  38. Replies
    58
    Views
    4,711

    This irritates me more than whats in the...

    This irritates me more than whats in the pictures. Low baller, not sure who would work for free but you did.
    Working that cheap, are you going to be around in 9 years when it needs a fan motor...
  39. Replies
    58
    Views
    4,711

    What he said ^

    What he said ^
  40. Replies
    58
    Views
    4,711

    Huh?

    Huh?
  41. Replies
    12
    Views
    1,928

    14-3 with a ground. Mc cable or greenfield yes. ...

    14-3 with a ground. Mc cable or greenfield yes. Works well.


    Not worried about the plumber, not my problem. Project is so ignorant.
  42. Replies
    12
    Views
    1,928

    https://farm8.staticflickr.com/7625/16669044129_ad...

    https://farm8.staticflickr.com/7625/16669044129_adad44026f_h.jpg

    Don't get me started about the framing. Entire thing is a towering piece of $hit.
  43. Replies
    12
    Views
    1,928

    Well.... We did this one a bit different than...

    Well.... We did this one a bit different than before. Started by cutting sheets of 7/16" osb 1" smaller than the units, that will leave a half all the way around. On the left side of the piece of osb...
  44. Replies
    12
    Views
    1,928

    Believe they were mxc-2z, yep multi-zone hyper...

    Believe they were mxc-2z, yep multi-zone hyper heat
  45. Replies
    12
    Views
    1,928

    Pair of 2 zone hyper heat units

    Don't think these are even in the catalog yet.
    https://farm8.staticflickr.com/7605/16841670871_7d4352cb6c_h.jpg
    https://farm8.staticflickr.com/7597/16635426407_6e5012512e_h.jpg

    Roughed them in...
  46. Thread: Flue disaster

    by jimmyed
    Replies
    8
    Views
    2,481

    Had all the materials at the shop, and only a few...

    Had all the materials at the shop, and only a few minutes from the shop.
  47. Yeah, Im not out to try and sell every customer a...

    Yeah, Im not out to try and sell every customer a new furnace just because its old. If sized right, these old things keep chugging along. When the heat ex does go, I've never had one with co in the...
  48. Replies
    24
    Views
    3,863

    Don't need a drain trap... Furmaces don't go in...

    Don't need a drain trap... Furmaces don't go in attics but that one isn't bad. Only concern would be not having a pan under the furnace, what if it had a leak?
  49. 45ACP

    45ACP
  50. I had a pile of dead parts at the end of the day today.

    https://farm8.staticflickr.com/7652/16169556973_10e9face36_h.jpg
    All in a days work...




    Said he thought he had a bird get in the chimney pipe.

    ...
Results 1 to 50 of 725