  1. Replies
    80
    Views
    1,947

    Lieberts now come with 407c in them. Many with...

    Lieberts now come with 407c in them. Many with the same R-22 compressors they always had. There's a small difference in settings but no big deal. I do not know if Liebert did a bunch of research and...
  2. Replies
    19
    Views
    911

    I find several issues with these units. It's...

    I find several issues with these units. It's hardly redundant. The unit has two compressors and two heat exchangers with no isolation valves, and one very expensive pump. The controller has no useful...
  3. Replies
    19
    Views
    911

    Unit is a KKT Kraus, model KSC 215-L-U/S, Bladder...

    Unit is a KKT Kraus, model KSC 215-L-U/S, Bladder style expansion tank which is part of the chiller. Closed loop. No storage tank. One pump. Everything on it is in German. Can't shut anything off...
  4. Replies
    19
    Views
    911

    Good idea.

    Good idea.
  5. Replies
    19
    Views
    911

    Yes it has an expansion tank. It sounds empty....

    Yes it has an expansion tank. It sounds empty. You are right there must be a leak. It has very thick insulation. I shall not give up.
  6. Replies
    19
    Views
    911

    This is a sealed loop.

    This is a sealed loop.
  7. Replies
    19
    Views
    911

    Where does the water go?

    We take care of a couple of little Kraus chillers for some MRI machines. We have had to add a little water (perhaps a gallon or two) to them a few times because the suction side of the pump goes down...
  8. Replies
    2
    Views
    234

    What company is that from?

    What company is that from?
  9. Replies
    3
    Views
    322

    Top section of indoor coil dry

    Lennox, 13CHPA-36-230=1A, S#1607K07565, package heat-pump.
    Reported problem: Not keeping up in the afternoon. Goes to a bank in a supermarket.
    Outdoor 105*, outdoor RH 22%, indoor at stat 78*,...
  10. Replies
    11
    Views
    1,193

    Yes, I found out: don't turn on the compressor if...

    Yes, I found out: don't turn on the compressor if there's cleaner in there. Froze up solid in no time. haha.
  11. Excellent info, thank you.

    Excellent info, thank you.
  12. Replies
    29
    Views
    1,369

    Your market experience and attitude makes you a...

    Your market experience and attitude makes you a valuable person to other areas of this field.
    I too liked markets because they were complex and important. I did supermarkets for 20 years. It beats...
  13. Follett ice machine intermittently trip drive amps.

    We have just started taking care of 50+ Follett ice machines in a hospital complex. We get a lot of calls with drive amp trips. Sometimes it has been just ice backing up in the transport tube for a...
  14. Replies
    11
    Views
    1,193

    I see amps the same as you see. They seem to be...

    I see amps the same as you see. They seem to be very picky units. They must make their money on selling bearings.

    I have been finding on some Follett machines if the tube is not perfect; If it...
  15. Replies
    7
    Views
    261

    Was there some issue with power stealing? I see...

    Was there some issue with power stealing? I see most honeywell stats allow batteries and say Common is optional if you have batteries.
  16. Thread: PM check list

    by mccann
    Replies
    26
    Views
    1,101

    Perhaps they know it is ridiculous, but it keeps...

    Perhaps they know it is ridiculous, but it keeps the pressure on the workers to move faster and find a way. Perhaps they just don't have time or skill to take such things into consideration. ...
  17. Thread: PM check list

    by mccann
    Replies
    26
    Views
    1,101

    The reason for these check lists is because of...

    The reason for these check lists is because of the many, very large, national, 3rd party, management companies managing large properties from a distance. Our corporate sales people talk to their...
  18. Thread: C Vs Z charge

    by mccann
    Replies
    8
    Views
    401

    The z charge is for low temp. If it's working, be...

    The z charge is for low temp. If it's working, be thankful. If it's not. Check if you got enough liquid there first. If it's on a system, Valve off other units to see if refrigerant feeds better to...
  19. Thread: PM check list

    by mccann
    Replies
    26
    Views
    1,101

    PM check list

    What do you guys think when they give you little time per unit and a PM check list from the customer that asks for amps of everything, pressure safeties tested, superheats and lots of other things?...
  20. Replies
    17
    Views
    12,006

    One less likely possibility; How is the...

    One less likely possibility; How is the superheat? I had a package unit years ago fling water past the pan because the coil was not being feed evenly. It was dry in sections and water seemed to blow...
  21. Replies
    30
    Views
    1,840

    As to the original question; how long before...

    As to the original question; how long before damage? It depends on the humidity at the time, how open open was, how saturated with refrigerant the oil was, the condition and quality of the drier. ...
  22. Replies
    22
    Views
    1,360

    I don't know. You never really know. I like to...

    I don't know. You never really know. I like to have a core removal tool handy with the core remover stem taken out. If refrigerant starts blasting, you can put the removal tool over the schrader,...
  23. Replies
    3
    Views
    541

    The more they want to change, the more we make...

    The more they want to change, the more we make money.
    Robots will build it so well, it will never need service.
  24. Some units reheat by having a secondary condenser...

    Some units reheat by having a secondary condenser coil in the supply. I thought that cool.
  25. Replies
    28
    Views
    2,826

    Assuming motor is good, coil is clean, pressure...

    Assuming motor is good, coil is clean, pressure control is working correctly, wiring is tight; Data-Aire seems to have this issue; like the P66 is not fast enough on a cold night, when your not...