    I use the fluke 1587(i believe that's the correct...

    I use the fluke 1587(i believe that's the correct model number) it's a meggar/meter combo. Love it. Found plenty of nuisance problems, and i use it when my reg meter takes a plunge.
  2. Replies
    8
    Views
    569

    I use a d-tek on all freons. It doesnt like...

    I use a d-tek on all freons. It doesnt like finding 404 or 410, sometimes no problem, sometimes big problem. I picked up a new JB prowler that has a vibrating function that helps esp when it's in a...
  3. Replies
    5
    Views
    407

    I won't do a manual J until if got the job. The...

    I won't do a manual J until if got the job. The contractor was aware of the windows an insulation if he suggested a lower btu furnace. Manual j takes time. And if im seeing alot of customers just...
  4. Replies
    20
    Views
    903

    I use bow bender for everything i can. Regular...

    I use bow bender for everything i can. Regular and reverse bends. Cuts down on the amount of welds and it's pretty compact
  5. Biggest thing is make sure the compressor has a...

    Biggest thing is make sure the compressor has a sound blanket.
  6. Thread: Work boots!

    by Crazecodyk
    Replies
    92
    Views
    8,198

    I've always work wolverines. Was going through...

    I've always work wolverines. Was going through two pair a yr. last round i bought some redwings hoping that they'd last longer esp since they were 189.00. They are comfy but sadly no more life than 6...
  7. Replies
    4
    Views
    261

    Congrats and welcome. One question though. When...

    Congrats and welcome. One question though. When you say branch out on tour own do you mean with in your family company as a partner or clean slate, new name new everything? If you like having family...
  8. Replies
    8
    Views
    480

    Went back to check, low mv signal, told customer...

    Went back to check, low mv signal, told customer price and they said nopie, which i was glad to hear. They ended up covering the hole and mounting heater on the wall in front of it
  9. Replies
    8
    Views
    480

    300. Cool. That's what i was looking for.

    300. Cool. That's what i was looking for.
  10. Replies
    8
    Views
    480

    Williams Wall Heater questions

    i have a williams wall furnace that a customer is wanting to get going again, hasn't ran in probably over ten years.
    the model # 35GV-5 s# A47820
    Does not look like it has a blower assembly,...
  11. Simple fact: HO took charge to change his t-stat....

    Simple fact: HO took charge to change his t-stat. Unit was running beforehand. There is no way that's a warranty call. That's a service charge through and through. No gray area here. How it should be...
  12. Replies
    2,795
    Views
    60,514

    I don't need to, but it is a right given to me by...

    I don't need to, but it is a right given to me by the 2nd amendment, it is also my choice to own guns for various reasons. Hunting,personal defense, recreational events, and the most important reason...
  13. Replies
    8
    Views
    419

    Check your supply voltage to your primary side of...

    Check your supply voltage to your primary side of transformer, make sure correct voltage is being used.
    Then i would check on output side of transformer,
    If all good there check for loose...
  14. I strongly say yes to drug testing for a...

    I strongly say yes to drug testing for a privileged commodity. I have to get drug tested so i can make my money and i far too often seen where my money goes and who it "helps" more people abuse the...
  15. Replies
    3
    Views
    614

    There are ample day and night (carrier) units i...

    There are ample day and night (carrier) units i service that are 20+ yrs old. Good product. I prefer carrier builds as opposed to trane. Easier access of parts and cheaper to repair. The unit will...
  16. Replies
    18
    Views
    997

    That would be great!!! The book i have is the...

    That would be great!!! The book i have is the daily operations manual. I hope next year after my business picks up i can go to classes on these. This is a great customer and we have a great...
  17. Replies
    18
    Views
    997

    I've installed theses VAVs in the past but never...

    I've installed theses VAVs in the past but never set one up to run off tracer. I would like to learn more of that. I have books that i am slowly reading through to self teach me.
    I was able to get...
  18. Replies
    18
    Views
    997

    Ok. After looking at it today. Was able to bring...

    Ok. After looking at it today. Was able to bring it on via tracer system. I don't think the vav has been fully set up yet my the trane guys. So i've got it in manual mode till the rest of the...
  19. Replies
    18
    Views
    997

    So if the dips 5&6 are in the on position that...

    So if the dips 5&6 are in the on position that should be the tracer address for that unit?
  20. Replies
    18
    Views
    997

    On another note. What do the dip switches control...

    On another note. What do the dip switches control on the ucm board?
  21. Replies
    18
    Views
    997

    I will check that tomorrow. It is connected to...

    I will check that tomorrow. It is connected to tracer software, set to thumb wheel control. I have not verified actual cfm output but i do know blower is running wide open and nada.
  22. Replies
    18
    Views
    997

    The common goes strait from board to contactor....

    The common goes strait from board to contactor. Check wire continuity and a new temp wire from board to contactor. So im thinking it's internal to the board.
  23. Replies
    18
    Views
    997

    Varitrane VPEF heat troubles

    I have a varitrave vpef vav box with a ucm4.2 board. This is a 460v 3 phase unit. On a call for heat the blower will come on, make the air switch and and go to the contactor that beings on the heat...
  24. Replies
    38
    Views
    2,050

    I always carry a transformer with a built in...

    I always carry a transformer with a built in circuit breaker when i come across a bad transformer... I use it as a troubleshoot aid
  25. Replies
    27
    Views
    2,521

    Ive kept with Milwaukee. Always had good luck....

    Ive kept with Milwaukee. Always had good luck. Can't bash any brand. Just chose mine and am keeping with it