Search:

Type: Posts; User: alliedtech12887

Page 1 of 5 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    10
    Views
    370

    If it's a constant volume there has to be some...

    If it's a constant volume there has to be some type of bypass of relief damper for static control.


    Sent from my iPhone using Tapatalk
  2. Replies
    1
    Views
    234

    Controls vs Large Tonnage work.

    I currently work for a mechanical contractor doing mainly controls but received an offer from a factory company doing large tonnage work. Has anyone came from one field to the other? I like doing...
  3. Replies
    12
    Views
    622

    All depends how severe the burnout is. ...

    All depends how severe the burnout is.


    Sent from my iPhone using Tapatalk
  4. Thread: Unions

    by alliedtech12887
    Replies
    12
    Views
    268

    The sheet metal union and plumbers/fitters unions...

    The sheet metal union and plumbers/fitters unions do completely separate work. When your in the sheet metal Union all your doing is knocking tin. If your a hvac tech in the plumbers/fitters Union...
  5. Replies
    0
    Views
    164

    New job opportunity

    So I've been working for a large mechanical contractor now for about 8years and last week I revived a job offer from our local trane branch. The new job has a little more vacation and holidays but...
  6. Replies
    8
    Views
    599

    What I'm trying to get at is are you going to be...

    What I'm trying to get at is are you going to be replacing controllers one at a time or every controller on the trunk at once?


    Sent from my iPhone using Tapatalk
  7. Replies
    8
    Views
    599

    Are you looking to replace every device on the...

    Are you looking to replace every device on the network? Also what protocol is currently in place N2...bacnet?


    Sent from my iPhone using Tapatalk
  8. Replies
    2
    Views
    199

    If there's no heart beat from the status light...

    If there's no heart beat from the status light chances are it's cooked.


    Sent from my iPhone using Tapatalk
  9. Replies
    10
    Views
    633

    Have you had a good controls contractor work on...

    Have you had a good controls contractor work on the "cancer metasys"? It's probably a simple fix if you know what your doing.


    Sent from my iPhone using Tapatalk
  10. Replies
    3
    Views
    327

    Trane Tracer TU Issue

    If you read my topic that's what I'm asking. The software will work fine for a week or so then when I open the software it will give and error saying the computers id does not match the license and...
  11. Replies
    3
    Views
    327

    Trane Tracer TU Issue

    Has anyone had an issue with the tracer TU software and their computer ID number. I keep having to contact my local trane dealer to provide me with a new licence because my computers ID number keeps...
  12. Replies
    17
    Views
    869

    Id recommended subbing out all the electrical to...

    Id recommended subbing out all the electrical to a electrician with controls experience. When it comes to the remaining work its all job dependent. Is it custom control work? Is it cookie cutter VAVs...
  13. Customizing Niagara Home Page Graphics

    Just seeing what people are using to build custom Niagara graphics?


    Sent from my iPhone using Tapatalk
  14. Replies
    4
    Views
    270

    Well I have an older building with two NAE55 that...

    Well I have an older building with two NAE55 that are pulled into site viewer. One of the NAEs has crashed and I'm trying to bring it back to life without issue.


    Sent from my iPhone using...
  15. Replies
    4
    Views
    270

    Metasys NAE NUT Tool and 2.1 File

    Looking for a copy of the Metasys NAE NUT Tool and 2.1 File. Would anyone have something they'd be so kind to share?


    Sent from my iPhone using Tapatalk
  16. Replies
    1
    Views
    179

    NAE Hyperterm Question

    I had a building with an NAE loose power over the weekend and when the NAE started back up it Enabled DHCP and also changed the default ip setting. Can you make changes to the NAE setttings in...
  17. Replies
    14
    Views
    1,888

    I autographed it...... No the writing is from the...

    I autographed it...... No the writing is from the electrician, he wrote out the panel location and circuit #.


    Sent from my iPhone using Tapatalk
  18. Replies
    5
    Views
    264

    If the building has a chiller plant and is...

    If the building has a chiller plant and is supplying chilled water to the condos there is no need for a heatpump. It would actually cost the resident more money in electrical utilities.


    Sent...
  19. Run.. Run far away Sent from my iPhone...

    Run.. Run far away


    Sent from my iPhone using Tapatalk
  20. Replies
    14
    Views
    1,888

    Yes there JCI FX07s Sent from my iPhone...

    Yes there JCI FX07s


    Sent from my iPhone using Tapatalk
  21. Replies
    14
    Views
    1,888

    Custom Controls Cabinet

    A custom heat pump control cabinet from last summer. This is the way a controls panel should look.
    563051563061


    Sent from my iPhone using Tapatalk
  22. Replies
    0
    Views
    533

    FX60 Graphic sizing

    A customer of mine did something to his laptop and the FX60 graphic are smaller and don't fill up the screen (see attached picture). I viewed the station from my computer and everything looks fine....
  23. Replies
    11
    Views
    915

    They still make new DX's? J/k we haven't...

    They still make new DX's? J/k we haven't installed a new DX since the FX Line came available and now with PCG coming available in N2 you'd be foolish to install anything else.
    New DX-$2435.00
    New...
  24. Replies
    32
    Views
    4,926

    Does it look like it? To answer your question NO...

    Does it look like it? To answer your question NO


    Sent from my iPhone using Tapatalk
  25. If you've already got a Modbus card you could use...

    If you've already got a Modbus card you could use a Babble Buster to convert it to BACnet MSTP. We recently used this setup on some PK Boilers. http://www.csimn.com/CSI_pages/BB2-3010.html


    Sent...
  26. Replies
    2
    Views
    330

    Bumpp

    Bumpp
  27. Replies
    0
    Views
    253

    Rapid Air ICS II controller

    Looking for some information on the Rapid Air ICS II Controller. We have an account with 11 Rapid Air make up units that are on a RS-485 network and tie back to a computer with Rapid Airs monitoring...
  28. Replies
    2
    Views
    330

    Rapid Air ICS II Controller.

    Looking for some information on the Rapid Air ICS II Controller. We have an account with 11 Rapid Air make up units that are on a RS-485 network and tie back to a computer with Rapid Airs monitoring...
  29. Replies
    27
    Views
    2,018

    99% of the time it comes down to installation and...

    99% of the time it comes down to installation and commissioning. We do work for several local school districts and have replace a decent amount of pneumatics with ddc. In the last 2 years we've only...
  30. Replies
    11
    Views
    865

    Second-Year Advice

    Check out these Kentucky Local Unions, they off great apprenticeship training and very competitive rates.
    537861


    Sent from my iPhone using Tapatalk
  31. Smart Thermostat that can do Space Temp & Humidity Ctrl?

    Does anyone know of a Smart Thermostat that can do Space Temp & Humidity Ctrl on a package RTU? I looked through the JCI Tec Stats but couldn't find anything.


    Sent from my iPhone using Tapatalk
  32. Replies
    11
    Views
    1,418

    Do your job and keep the customer happy. Then you...

    Do your job and keep the customer happy. Then you won't have to worry about "other contractors"


    Sent from my iPhone using Tapatalk
  33. Replies
    3
    Views
    510

    Yea I'm running PCT 10.0.0.1059, I had a spare...

    Yea I'm running PCT 10.0.0.1059, I had a spare PCG2611 at the office I was able to commission with no issues.
  34. Connecting to a Trane VariTrac Central Control Panel?

    Looking for some info on connecting to an older trane VariTrac central controller. I have a older version of rover but I believe this controller might run through hyper terminal. Also looking for the...
  35. Replies
    3
    Views
    510

    JCI FX-PCT Issue

    I'm trying to commission a new FX-PCG2611-0 but when I try to connect it it through the PCT Tool im getting a error message "The selected file cannot be opened due to a formatting or tool...
  36. Replies
    51
    Views
    9,355

    530721

    530721
  37. Replies
    51
    Views
    9,355

    It's common with all these style boilers, they...

    It's common with all these style boilers, they run off priority demand and DHW is always priority #1.
  38. Boston train is union.

    Boston train is union.
  39. Yea I'm currently in the union.

    Yea I'm currently in the union.
  40. Replies
    31
    Views
    1,899

    Stop dicking around and get the correct motor.

    Stop dicking around and get the correct motor.
  41. Thinking about switching contractors.

    I currently work for a large mechanical contractor and received a job offer from our local Trane Office. At the company I currently work for I do about 50% controls and 50% commercial mechanical...
  42. Disconnect the heating relay and safeties, then...

    Disconnect the heating relay and safeties, then turn the system to heat and see if it trips.
  43. I don't think it really comes down to throw, it's...

    I don't think it really comes down to throw, it's more about proper sizing using BTUs, Square Footage, and heat loads.
  44. Replies
    32
    Views
    4,926

    No it's actually a fire station in RI.

    No it's actually a fire station in RI.
  45. Replies
    32
    Views
    4,926

    Ugly controls cabinet

    The mechanical contracting company I work for recently took over a new account. I went out there today to do a review of the BMS and found multiple panels like this. This is pretty much a brand new...
  46. Replies
    36
    Views
    5,413

    Is that a Multistack?

    Is that a Multistack?
  47. Trane BACnet RTU BCI-R Board Help.

    Yea I have that literature, it doesn't show the bacnet connections.521271
  48. Trane BACnet RTU BCI-R Board Help.

    Looking for some help with bacnet mstp wiring regarding the Trane BACnet RTU BCI-R Board. In the literature it doesn't really explain which terminals are for the comm wire. I included a photo of the...
  49. JCI FX30 Help!! "loading lexicon list" Stall

    Im trying to connect to a new FX30. Ive loaded the updates into the 30 via work bench and im able to connect to the 30 with my laptop but when using the customers older laptop the FX30 starts to boot...
  50. Norlake CB0751C-A Walk-in Half Evap Frosting?

    Working on a Norlake CB0751C-A Walk-in and while the system is running only half the evaporator is frosting up. It's a TXV R22 style system, I've weighted in the correct charge and checked superheat....
Results 1 to 50 of 206
Page 1 of 5 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Comfortech365 Virtual Event