Search:

Type: Posts; User: gan

Page 1 of 13 1 2 3 4

Search: Search took 0.01 seconds.

  1. Thread: Long Load Times

    by gan
    Replies
    12
    Views
    959

    I turn that feature off and I also don't have it...

    I turn that feature off and I also don't have it store any temp files on the local computer and that has minimized my issues with Java and the supervisors.
  2. Replies
    18
    Views
    2,162

    on a temp input you should see -98 if there is...

    on a temp input you should see -98 if there is nothing connected to it if you short the wires together you should read a temp reading over 100 deg, I can't recall the actual value right now. If the...
  3. Thread: Alerton AIE Jace

    by gan
    Replies
    4
    Views
    753

    we use Alerton Jaces and I use tridium/niagara ...

    we use Alerton Jaces and I use tridium/niagara have you tried admin/bas I know on jaces we setup as supervisors the log in are diffrent
  4. Replies
    13
    Views
    2,097

    yes and no the new 3.0 of envision still...

    yes and no the new 3.0 of envision still functions like envision, we have our own AX front end that we install so we don't use envision but to right our code and program controllers. Haven't played...
  5. Replies
    13
    Views
    2,097

    Dang it I haven't even installed the honeywell...

    Dang it I haven't even installed the honeywell 3.6 yet on my laptop just the Alerton version 3.6
  6. Replies
    10
    Views
    1,380

    if it is a serial port key then I would say an...

    if it is a serial port key then I would say an early version of envision, I have a usb tech key for envision that I have used on ebt version 2.0-2.6 I now have ebt 3.0 which is the newest version and...
  7. Replies
    10
    Views
    1,380

    The new ebt 3.0 is a software key no more usb key...

    The new ebt 3.0 is a software key no more usb key that you needed on ebt 2.6 and down.
  8. Replies
    11
    Views
    1,490

    From visio you can change the controller setting...

    From visio you can change the controller setting to enable writes to ddc discriptors. Just double click on the controller icon usually on the first page, from there you can also pull the DDC...
  9. Thread: Alerton Training

    by gan
    Replies
    2
    Views
    1,043

    I have done the e100, 230 online and lab portion...

    I have done the e100, 230 online and lab portion and gone through the 400 which is the programing course. I didn't do the HVAC basics course though, the courses breaka down what the diffent levels of...
  10. Replies
    21
    Views
    4,531

    I have small tool pouch I use for about 90% of my...

    I have small tool pouch I use for about 90% of my work, if I need some serious tools I will bust out the veto. I used to be a strictly tool bag guy till I started doing controls and don't need to be...
  11. Thread: fluke 116

    by gan
    Replies
    16
    Views
    1,888

    Agreed wish it had a milliamp setting, despite...

    Agreed wish it had a milliamp setting, despite that its still my everyday driving meter that I carry in my laptop bag.
  12. Replies
    9
    Views
    982

    I wlll overide the point and manually drive it, I...

    I wlll overide the point and manually drive it, I have a simulator and it sits in the truck I have never used it.
  13. The word through the grapevine is TD Industries...

    The word through the grapevine is TD Industries is moving into an office in Weslaco and they are looking for a tech, not sure how true it is but its worth taking a look into.
  14. Howdy from a fellow RGV tech, I got a buddy who...

    Howdy from a fellow RGV tech, I got a buddy who just graduated from TSTC and is having a hard time finding a job, I was in your shoes just last year. Now I work for a company out of San Antiono...
  15. Replies
    81
    Views
    9,537

    Thanks I recieved my parts for the valve and you...

    Thanks I recieved my parts for the valve and you guys even sent me a new hanger since I mentioned mine got streched out. You guys are awesome, I will looking into getting a leak detector from you...
  16. Replies
    18
    Views
    3,318

    I emailed you my address and I haven't recieved a...

    I emailed you my address and I haven't recieved a reply, or there is no reply sent?
  17. Replies
    4
    Views
    999

    Was there a actuator before? Or are you adding...

    Was there a actuator before? Or are you adding the actuators after the fact. Are they modulating or or open/close, I am guessing modulating if so you will need a AO point to send the correct signal....
  18. Thread: Digital Gauges

    by gan
    Replies
    12
    Views
    861

    I got a Sman 3 I really it, made my job alot...

    I got a Sman 3 I really it, made my job alot easier and now I don't have to carry around a temp meter, or vacumm gauge. Only wish it was a 4-valve manifold really like that setup.
  19. Replies
    201
    Views
    15,864

    Well my zx-1 is dying I have had it repaired once...

    Well my zx-1 is dying I have had it repaired once already, I was using it Satruday and it was reading then not reading a leak, it won't power down anymore I have to pull the battery to turn it off....
  20. Replies
    5
    Views
    1,382

    I have setup several jaces and its straight...

    I have setup several jaces and its straight foward like MrBil said, I am going to have to try the enabling of the 2nd ethernet port. I have had to shell into the jace before to fix my mistake used...
  21. Replies
    15
    Views
    3,425

    ASN= Alerton support network, its where you can...

    ASN= Alerton support network, its where you can get all the manuals and programs for Alerton products
  22. Thread: Aaon Wattmaster

    by gan
    Replies
    29
    Views
    6,380

    We have done the pt link via bacnet and didn't...

    We have done the pt link via bacnet and didn't have any issues, we also did one recently with a bacnet pt link into a tridium front end it was super easy, no issues. We recently started doing full...
  23. Replies
    11
    Views
    2,988

    My yellow jacket quit on me working on my AC at...

    My yellow jacket quit on me working on my AC at my house, so now I am looking at getting the G5. I did get 4yrs out of the yellow jacket I guess thats not to bad.
  24. Replies
    24
    Views
    3,639

    I just finished a job that TAB and set the static...

    I just finished a job that TAB and set the static pressure to 1.75" thats the highest I have seen so far.....
  25. Replies
    42
    Views
    3,850

    I picked one up and keep it in my wallet now, I...

    I picked one up and keep it in my wallet now, I just got used to it over the years I would read my pressure my temps was like second nature to me with my analog gauges. Now I got 5 pairs of analog...
Results 1 to 25 of 306
Page 1 of 13 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event