  1. Replies
    4
    Views
    642

    1 year expect some where between 10 n 15 per hour...

    1 year expect some where between 10 n 15 per hour if there is work
    things are slow here and may take time for it to pick up
  2. 20 gallons a day and it isnt water logged you...

    20 gallons a day and it isnt water logged you have a leak some where look for it before you damage the boiler
  3. just saw the vidio. Looks like the typical nc...

    just saw the vidio. Looks like the typical nc system. Looks like you may have a damper zone system from the control on the furnace.
    you would IMHO do better and save more by ripping it all out and...
  4. Replies
    12
    Views
    360

    yes it does

    yes it does
  5. Replies
    12
    Views
    360

    the termintions look a little close to the corner...

    the termintions look a little close to the corner
    most units want up to 8 ft from a corner or side wall
    was a permit pulled and was it inspected??
  6. there is some info missing test resolts are...

    there is some info missing
    test resolts are important here to answer properly
    if it is warm out then yes drat could be low
    what were his reading after the unit was running for a while like 15...
  7. have to agree with Been on this one your leak...

    have to agree with Been on this one

    your leak should not be that hard to find and dye is a waist of time
  8. you have said you have no intentions of useing...

    you have said you have no intentions of useing this guy and stated he was an idiot
    he from what i have read did the load calc with a few minor mistakes witch leads me to think he did more for you...
  9. have the coil cleaned or at least the typre you...

    have the coil cleaned or at least the typre you sray on from a can and let it run off with the condensate

    sounds like it may be pulatants with an oil resadue
  10. how is it vented? May be tripping on presure...

    how is it vented? May be tripping on presure switch
    flame senser may need to be cleaned often if the gas isnt burning properly

    If it has the wrpilot sensor with the 45sec delay the secondary...
  11. Replies
    12
    Views
    529

    water flo is important if the new pump is 600...

    water flo is important
    if the new pump is 600 gph you may need to up size the intake piping to it and upsize the outlet piping
    you realy need to find the exact water flo you need to run the unit...
  12. with the 20i unit you need the trane zone panel...

    with the 20i unit you need the trane zone panel and proper stats for that panel

    any other zone panel will not work well and or stage the unit properly

    trane also to the best of my knowlege...
  13. Replies
    30
    Views
    1,481

    i have done many unit on log beach island that...

    i have done many unit on log beach island that went under decks and walkways
    some only had 12ins of clearance
    i would put a full size square elbow on the top of then to shoot the discharge air out...
  14. Replies
    6
    Views
    552

    have your friend juice it up for another six...

    have your friend juice it up for another six weeks and maybe you will be able to find a job and be able to replace the unit before to long

    if nothing else it may get you through the rest of the...
  15. Replies
    5
    Views
    488

    what doc said capacitors dont always look bad...

    what doc said

    capacitors dont always look bad they always need to be tested to be sure they have the proper rating
  16. back in the day it was not uncomon to find a unit...

    back in the day it was not uncomon to find a unit on a roof or in sun on a 100 degree day to run at 350 or so
    check it when it cools dow if it ever does
  17. Replies
    4
    Views
    396

    fan relay come to mind time for the techs to do...

    fan relay come to mind
    time for the techs to do thier job and fix it


    mr bill i heard they are now useing horses
  18. not sure any of us can be of help. We are limited...

    not sure any of us can be of help. We are limited on just how much advice we can give

    tell us what is happening and decribe the best you can
  19. Replies
    13
    Views
    726

    if the coil is clean and the fan blade isnt...

    if the coil is clean and the fan blade isnt blowing hot air through the top of the condenser coil raising your head pressure

    you may want to check your lineset for a posible kink and someone is...
  20. Replies
    32
    Views
    1,802

    very informative tread i was taught in a few...

    very informative tread
    i was taught in a few class that you bring it close as possible with liquid and you can fine tune the sh n sc as a gass

    aside from the fact the helper was in the wrong and...
  21. come on give the guy a break

    come on give the guy a break<<< he is trying to learn as we were at some time

    100 years ago when i was first starting beer can cold was the way it was taught. as time went on you learn the right...
  22. Replies
    29
    Views
    2,414

    found years ago in a weak market more isnt better...

    found years ago in a weak market more isnt better
    charge what you charge and hold level and the customers will still be with you when the market is better

    a good tech is worth his wieght in gold...
  23. didnt see the size of the unit so spoke to soon ...

    didnt see the size of the unit so spoke to soon on cfm
    i do tend to feel there is an airflo issue
  24. anytime you go on a call you collect diagostic...

    anytime you go on a call you collect diagostic repair or not
    this means you go through the entire system and check it out if approved you do the repair and check it over again to be sure you havent...
  25. Replies
    16
    Views
    1,251

    very posibal they took out the one and forgot to...

    very posibal they took out the one and forgot to install the one in the bag and there is no piston

    pump it back and check