  1. Thread: Aaon units

    by joeblo
    Replies
    18
    Views
    1,048

    I am really pleased with Orion tech support, the...

    I am really pleased with Orion tech support, the Aaon units them selves, not so much.
  2. Replies
    7
    Views
    409

    Is the furnace dirty and sucking in a lot of...

    Is the furnace dirty and sucking in a lot of dust? Is there something in the air that could be burning to it? What are you using to clean it with? Don't use sand paper. I just use a small wire brush.
  3. Replies
    17
    Views
    840

    I called honeywell last week and ask the same...

    I called honeywell last week and ask the same question. In short the answer is no. The t'stat adapts to differing conditions such as run time, cycles, and tempatures. The same thermostat hooked to...
  4. Replies
    17
    Views
    1,228

    The more often it is cleaned the less time and...

    The more often it is cleaned the less time and work to clean it. I have seen some that were so bad that they could not be cleaned with out complete disasembly.
  5. Thread: wifi thermostat

    by joeblo
    Replies
    16
    Views
    1,261

    Just installed a Honeywell vision Pro a couple of...

    Just installed a Honeywell vision Pro a couple of weeks ago. Easy to use and set up, home owner loves it. I believe it only cost me about $30 more than the standard touch screen.
  6. Replies
    33
    Views
    1,600

    Thats what I was thinking. Maybe the check valve...

    Thats what I was thinking. Maybe the check valve to the air coil is stuck. If the charge is right, coil is clean and good air flow THROUGH coil,(make sure air is not bypassing coil some how),thats...
  7. Replies
    22
    Views
    1,431

    Check the burner orifices to see if they are...

    Check the burner orifices to see if they are plugged. I've seen them plugged with bugs and spider webs. Also check gas pressure in and out of valve.
  8. Thread: Rheem heat pump

    by joeblo
    Replies
    7
    Views
    699

    Could be outdoor t'stat issue as well.

    Could be outdoor t'stat issue as well.
  9. Replies
    15
    Views
    654

    Longer run times equals less cycling and fewer...

    Longer run times equals less cycling and fewer brake downs, more even temps, and the difference in efficiency would be very minor.
  10. Replies
    19
    Views
    1,601

    I never heard of it either. I always supply my...

    I never heard of it either. I always supply my own refrig. and use what the manufacture recommends. I would tell him if he wants it charged with that, then he can do it.
  11. Replies
    14
    Views
    868

    Oil furns put out hotter air, but lower temp air...

    Oil furns put out hotter air, but lower temp air and longer run times produce a more comfortable house. You will have a hard time convincing people of that if they have always used oil.
  12. Replies
    15
    Views
    654

    Best is to offer all the pros and cons and let...

    Best is to offer all the pros and cons and let the customer decide. In my house I would use 2 stage stat.
  13. Replies
    22
    Views
    1,589

    Check the vacuum to the switch, maybe the line is...

    Check the vacuum to the switch, maybe the line is plugged up or there is water in furnace due to a plugged drain.
  14. Replies
    8
    Views
    612

    I think he is currently taking a test.

    I think he is currently taking a test.
  15. http://www.trane.com/CPS/Uploads/UserFiles/Control...

    http://www.trane.com/CPS/Uploads/UserFiles/Controls/BAS-SVX36C-EN_03132012.pdf See if this works
  16. You can get it on tranes website. There are a few...

    You can get it on tranes website. There are a few that look like that so a part number would be helpful. They call it a display tempature sensor.
  17. Replies
    18
    Views
    2,153

    The toughest problems are the ones somebody else...

    The toughest problems are the ones somebody else created.
  18. Replies
    20
    Views
    1,310

    R-22 is not a mixed refrigerant. Subcooling is...

    R-22 is not a mixed refrigerant. Subcooling is the cooling after in has become 100% liquid (no bubbles). I would check to make sure your readings are correct and possibly a restriction before the...
  19. Replies
    3
    Views
    475

    My quess is there is a failure with the local set...

    My quess is there is a failure with the local set point. Just kidding, you may want to post this in the controls section.
  20. Replies
    10
    Views
    840

    Moisture creates acid in system.Suction line...

    Moisture creates acid in system.Suction line driers should be temporary and can create more problems if left in. A drier does not replace a proper evacuation, it does not remove noncondensables. I...
  21. Replies
    2
    Views
    1,052

    My only warranty claim with Ridgid was a broken...

    My only warranty claim with Ridgid was a broken head on my seesnake. I took it back to the distributor and was given a replacement, no questions or paper work.
  22. Replies
    10
    Views
    1,528

    It is a must have tool, I personally will not buy...

    It is a must have tool, I personally will not buy anything but an H10 but thats just me. Some places you can't see or get to with soap bubbles.
  23. Replies
    43
    Views
    3,220

    I buy 2 or 3 cheap meters at a time, they are...

    I buy 2 or 3 cheap meters at a time, they are always getting used, dropped,wet, etc..., having a spare is a must. I am currently using a $50 craftsman and have no problems with it. Astime goes on you...
  24. Replies
    15
    Views
    1,009

    If you jumper R to G and the fan switch on the...

    If you jumper R to G and the fan switch on the thermostat is in the auto position the A/C cond will come on, this is normal. Disconnect the Y when doing this. The relay on the circuit board that...
  25. Replies
    35
    Views
    1,810

    Check TXV in outdoor unit or check valve on...

    Check TXV in outdoor unit or check valve on indoor unit, hard to tell with out putting on gauges.If you have a high pressure going to the indoor unit and a low pressure coming back on the liquid line...