02-07-2013, 07:39 PM
Thread: Aaon units
by joeblo- Replies
- 18
- Views
- 1,048
I am really pleased with Orion tech support, the...
I am really pleased with Orion tech support, the Aaon units them selves, not so much.
-
02-07-2013, 07:31 PM
Thread: Lennox G60UHV-36B-090
by joeblo- Replies
- 7
- Views
- 409
Is the furnace dirty and sucking in a lot of...
Is the furnace dirty and sucking in a lot of dust? Is there something in the air that could be burning to it? What are you using to clean it with? Don't use sand paper. I just use a small wire brush.
-
02-07-2013, 07:24 PM
Thread: Honeywell Vision Pro 8000
by joeblo- Replies
- 17
- Views
- 840
I called honeywell last week and ask the same...
I called honeywell last week and ask the same question. In short the answer is no. The t'stat adapts to differing conditions such as run time, cycles, and tempatures. The same thermostat hooked to...
-
01-11-2013, 09:08 PM
Thread: cleaning ice mkr
by joeblo- Replies
- 17
- Views
- 1,228
The more often it is cleaned the less time and...
The more often it is cleaned the less time and work to clean it. I have seen some that were so bad that they could not be cleaned with out complete disasembly.
-
01-11-2013, 09:02 PM
Thread: wifi thermostat
by joeblo- Replies
- 16
- Views
- 1,261
Just installed a Honeywell vision Pro a couple of...
Just installed a Honeywell vision Pro a couple of weeks ago. Easy to use and set up, home owner loves it. I believe it only cost me about $30 more than the standard touch screen.
-
12-15-2012, 06:04 PM
Thread: mcquaid heat pump trouble
by joeblo- Replies
- 33
- Views
- 1,600
Thats what I was thinking. Maybe the check valve...
Thats what I was thinking. Maybe the check valve to the air coil is stuck. If the charge is right, coil is clean and good air flow THROUGH coil,(make sure air is not bypassing coil some how),thats...
-
12-13-2012, 05:52 PM
Thread: Reznor Warehouse Furnace
by joeblo- Replies
- 22
- Views
- 1,431
Check the burner orifices to see if they are...
Check the burner orifices to see if they are plugged. I've seen them plugged with bugs and spider webs. Also check gas pressure in and out of valve.
-
12-12-2012, 04:41 PM
Thread: Rheem heat pump
by joeblo- Replies
- 7
- Views
- 699
Could be outdoor t'stat issue as well.
Could be outdoor t'stat issue as well.
-
12-09-2012, 07:08 PM
Thread: york 2-stage question
by joeblo- Replies
- 15
- Views
- 654
Longer run times equals less cycling and fewer...
Longer run times equals less cycling and fewer brake downs, more even temps, and the difference in efficiency would be very minor.
-
12-09-2012, 06:09 PM
Thread: Propane based R22
by joeblo- Replies
- 19
- Views
- 1,601
I never heard of it either. I always supply my...
I never heard of it either. I always supply my own refrig. and use what the manufacture recommends. I would tell him if he wants it charged with that, then he can do it.
-
12-09-2012, 06:06 PM
Thread: Oil furnaces, more comfortable?
by joeblo- Replies
- 14
- Views
- 868
Oil furns put out hotter air, but lower temp air...
Oil furns put out hotter air, but lower temp air and longer run times produce a more comfortable house. You will have a hard time convincing people of that if they have always used oil.
-
12-09-2012, 06:00 PM
Thread: york 2-stage question
by joeblo- Replies
- 15
- Views
- 654
Best is to offer all the pros and cons and let...
Best is to offer all the pros and cons and let the customer decide. In my house I would use 2 stage stat.
-
12-06-2012, 04:29 PM
Thread: carrier 90% furnace
by joeblo- Replies
- 22
- Views
- 1,589
Check the vacuum to the switch, maybe the line is...
Check the vacuum to the switch, maybe the line is plugged up or there is water in furnace due to a plugged drain.
-
12-06-2012, 04:25 PM
Thread: I am a student and need some help please
by joeblo- Replies
- 8
- Views
- 612
I think he is currently taking a test.
I think he is currently taking a test.
-
12-06-2012, 04:18 PM
- Replies
- 3
- Views
- 353
http://www.trane.com/CPS/Uploads/UserFiles/Control...
http://www.trane.com/CPS/Uploads/UserFiles/Controls/BAS-SVX36C-EN_03132012.pdf See if this works
-
12-06-2012, 04:17 PM
- Replies
- 3
- Views
- 353
You can get it on tranes website. There are a few...
You can get it on tranes website. There are a few that look like that so a part number would be helpful. They call it a display tempature sensor.
-
12-04-2012, 06:56 PM
Thread: Supermarket Tech Question
by joeblo- Replies
- 18
- Views
- 2,153
The toughest problems are the ones somebody else...
The toughest problems are the ones somebody else created.
-
12-04-2012, 06:51 PM
Thread: BUBBLES IN SIGHT GLASS
by joeblo- Replies
- 20
- Views
- 1,310
R-22 is not a mixed refrigerant. Subcooling is...
R-22 is not a mixed refrigerant. Subcooling is the cooling after in has become 100% liquid (no bubbles). I would check to make sure your readings are correct and possibly a restriction before the...
-
12-02-2012, 08:48 PM
Thread: Trane Voyager trouble
by joeblo- Replies
- 3
- Views
- 475
My quess is there is a failure with the local set...
My quess is there is a failure with the local set point. Just kidding, you may want to post this in the controls section.
-
12-02-2012, 08:44 PM
Thread: How Important is a Dryer?
by joeblo- Replies
- 10
- Views
- 840
Moisture creates acid in system.Suction line...
Moisture creates acid in system.Suction line driers should be temporary and can create more problems if left in. A drier does not replace a proper evacuation, it does not remove noncondensables. I...
-
12-02-2012, 08:29 PM
Thread: Ridgid lifetime warranty on cordless tools
by joeblo- Replies
- 2
- Views
- 1,052
My only warranty claim with Ridgid was a broken...
My only warranty claim with Ridgid was a broken head on my seesnake. I took it back to the distributor and was given a replacement, no questions or paper work.
-
11-30-2012, 07:27 PM
Thread: Leak Detector Importance
by joeblo- Replies
- 10
- Views
- 1,528
It is a must have tool, I personally will not buy...
It is a must have tool, I personally will not buy anything but an H10 but thats just me. Some places you can't see or get to with soap bubbles.
-
11-30-2012, 07:14 PM
Thread: Starting Multimeter?
by joeblo- Replies
- 43
- Views
- 3,220
I buy 2 or 3 cheap meters at a time, they are...
I buy 2 or 3 cheap meters at a time, they are always getting used, dropped,wet, etc..., having a spare is a must. I am currently using a $50 craftsman and have no problems with it. Astime goes on you...
-
11-30-2012, 04:34 PM
Thread: Carrier 58PAV Trouble
by joeblo- Replies
- 15
- Views
- 1,009
If you jumper R to G and the fan switch on the...
If you jumper R to G and the fan switch on the thermostat is in the auto position the A/C cond will come on, this is normal. Disconnect the Y when doing this. The relay on the circuit board that...
-
11-30-2012, 04:27 PM
Thread: Heat Pump confusion
by joeblo- Replies
- 35
- Views
- 1,810
Check TXV in outdoor unit or check valve on...
Check TXV in outdoor unit or check valve on indoor unit, hard to tell with out putting on gauges.If you have a high pressure going to the indoor unit and a low pressure coming back on the liquid line...