08-02-2012, 09:40 PM
Thread: Digital Micron Guage
by philbilly88- Replies
- 26
- Views
- 3,157
i own a blu vac and like it alot....but the only...
i own a blu vac and like it alot....but the only down side that i have found is the 1/4male fitting instead of putting a female fitting on the gauge...what do u guys use on your micron gauge? a hose...
-
06-11-2012, 10:44 PM
Thread: york split system help
by philbilly88- Replies
- 7
- Views
- 614
yes that was a differential oil pressure of 40....
yes that was a differential oil pressure of 40. 100psi at the pump and it is a copeland semihermetic.and the unit is a 20+ year old york.
initially this unit was tripped on oil pressure and that is... -
06-11-2012, 06:29 PM
Thread: york split system help
by philbilly88- Replies
- 7
- Views
- 614
I adjusted 1 of the txvs but the other is non...
I adjusted 1 of the txvs but the other is non adjustable...not sure but im wondering if the tx might be stuck full open? I also added a pressure switch to the unloaderdue to unit runnin at 55 psi...
-
06-06-2012, 07:10 PM
Thread: york split system help
by philbilly88- Replies
- 7
- Views
- 614
york split system help
working on a york split system 15-20ton i guess..unit has 2 solenoids and txv's and compressor has an unloader. system was tripped on low oil pressure upon arrival-measured actual oil pressure and...
-
03-24-2012, 04:29 PM
Thread: detek select
by philbilly88- Replies
- 7
- Views
- 730
picked up multiple 407c leaks with my dtek and...
picked up multiple 407c leaks with my dtek and works great
-
01-31-2012, 06:57 PM
Thread: Gonna be doing some gas piping-----
by philbilly88- Replies
- 13
- Views
- 1,426
thats one heck of a piping job...looks like it...
thats one heck of a piping job...looks like it would have been pretty hard to thread 6' of pipe and make it right....NOT!
-
11-14-2011, 05:06 PM
Thread: trane 2stage 90% install
by philbilly88- Replies
- 10
- Views
- 1,353
no there isnt an alarm or safety switch on the...
no there isnt an alarm or safety switch on the pump...existing pump and we did not replace it per the boss
-
11-13-2011, 08:18 PM
Thread: trane 2stage 90% install
by philbilly88- Replies
- 10
- Views
- 1,353
schedule 40 pvc is all thats required in our...
schedule 40 pvc is all thats required in our area...ya i hate them midget basements they make for a long day...glad im in commercial now!!!
-
11-12-2011, 08:42 AM
Thread: trane 2stage 90% install
by philbilly88- Replies
- 10
- Views
- 1,353
ya it worked out really good...better than the...
ya it worked out really good...better than the old 1 inch filter in the blower compartment
-
11-11-2011, 08:51 PM
Thread: trane 2stage 90% install
by philbilly88- Replies
- 10
- Views
- 1,353
trane 2stage 90% install
old furnace was icp horizontal...new furnace trane 2stage 95% with macL filter enclosure.
-
11-11-2011, 08:29 PM
Thread: trane 2stage 90% install
by philbilly88- Replies
- 0
- Views
- 936
removed
removed
-
02-25-2011, 08:39 PM
Thread: Are you sure it was working?
by philbilly88- Replies
- 4
- Views
- 1,471
lennox pulse are junk anyhow, call it a loss and...
lennox pulse are junk anyhow, call it a loss and put a real furnace in!!!