  1. Replies
    33
    Views
    5,102

    We had a call for a hot server room at 3:00 a.m....

    We had a call for a hot server room at 3:00 a.m. on arrival at 4:00 found 12 units missing condenser coils and two units with the evaps hacked out. The thiefs were so crazy that they didn't even shut...
  2. Replies
    108
    Views
    10,012

    What a shame

    I've worked in the L.A. Market for years and there's no reason for that kind of poor install. The vent could be run properly with less fittings, the unit should be hung, read the install book from...
  3. Replies
    2
    Views
    633

    Figured it out

    This Mcquay unit is Dual circuited with two compressors tied together on each circuit. There is an isolation valve before the drier can so I shut that, jumpered the low pressure cutout and ran the...
  4. Replies
    2
    Views
    633

    Pumpdown a Mcquay Rdt115CLY

    Getting started with a new commercial group, they gave me a ticket to change cores on a Mcquay 115 ton unit that is frosting at the drier can. I see the unit pumps itself down at shutoff. Do I have...
  5. Thread: resi to comm

    by asticot
    Replies
    13
    Views
    1,109

    Just did the same..

    Shawn,
    I know the wonder/worry you're feeling. After 15 years doing Resi and light commercial I made the switch to full commercial and Industrial about two months ago. The good news is what you know...
  6. Replies
    6
    Views
    850

    Heard That!

    I just got a barely used Fluke 179 with remote amp clamp and a CO 210 detector from a kid that worked with us for three weeks for $200 bucks when he quit.
  7. Thread: back pack bag

    by asticot
    Replies
    3
    Views
    619

    Recently changed to the backpack

    I have always used an electricians style pouch, but now that I'm doing more commercial I noticed all the techs use the tool pac. So I broke down and bought one. It holds a lot more and it is great...
  8. Replies
    15
    Views
    1,196

    Hey Kerndt, I find that quite a lot in here in...

    Hey Kerndt, I find that quite a lot in here in CA. If your cubes are rough on the bottom or your getting a delayed harvest, sometimes you have to shut that machine down let the evap dry, then you...
  9. That's Funny!! If what you are saying is true...

    That's Funny!!
    If what you are saying is true the reason the Infinity can't see the condenser is becuase Carrier uses proprietary comm bus for control. Lennox will not communicate, only turn on and...
  10. Thread: Maintained?

    by asticot
    Replies
    17
    Views
    2,946

    I just have to ask, are those burners from a...

    I just have to ask, are those burners from a Consolidated(Premier) Furnace? It certainly looks like their cheap burner trays. We have replaced a ton of those furnaces.