04-13-2012, 05:55 AM
- Replies
- 8
- Views
- 734
check delta-t across condenser coil.
check delta-t across condenser coil.
-
03-10-2012, 12:34 PM
- Replies
- 0
- Views
- 305
Trane Rooftop Draft Motor KIT002590
I have a brand new in box never been opened a Trane Rooftop Draft Motor KIT002590..
If interested contact me and we can talk about a price... :cool: -
06-15-2011, 07:08 AM
Thread: Compressor operating in a vacuum
by chill out hvac- Replies
- 34
- Views
- 2,500
. How do you figure? You...
.
How do you figure? You mean that running my pump for 10 minutes and getting 100 microns is better than running it for 45 minutes and getting 500 microns? I have to disagree.... -
06-14-2011, 11:32 PM
Thread: Compressor operating in a vacuum
by chill out hvac- Replies
- 34
- Views
- 2,500
I could repeat myself, but that would be foolish!...
I could repeat myself, but that would be foolish!
500 Microns is how you pull a vacuum, a GOOD tech should know this basic knowledge... -
06-14-2011, 11:24 PM
Thread: Condenesing fans
by chill out hvac- Replies
- 9
- Views
- 517
do you have coil voltage at the compressor...
do you have coil voltage at the compressor contactor?
-
06-14-2011, 11:20 PM
- Replies
- 25
- Views
- 2,642
God only knows whats going on there, Some...
God only knows whats going on there, Some compressor just break internally and seize up.. If its not out on overload replace the compressor..
-
06-14-2011, 11:17 PM
Thread: Trap on Carrier rtu?
by chill out hvac- Replies
- 8
- Views
- 1,036
Ya most of those old green carriers are...
Ya most of those old green carriers are internally trapped.. Usually there's a sticker, but if faded stick ya finger in there like karl k suggested is the best way to tell...
-
06-14-2011, 11:13 PM
Thread: Compressor operating in a vacuum
by chill out hvac- Replies
- 34
- Views
- 2,500
275 microns is not a good vacuum, if that is all...
275 microns is not a good vacuum, if that is all you could get down to keep leak checking...
-
06-14-2011, 11:09 PM
- Replies
- 25
- Views
- 2,642
long story short, Feel the top of the...
long story short, Feel the top of the compressor.. If its smoking hot its out on overload.. Leave it off overnight, start it up in the morning. If you have 460v on every combo going into the...
-
06-14-2011, 11:01 PM
Thread: R-12
by chill out hvac- Replies
- 10
- Views
- 795
I got a 30lb of 409A if you are interested pm me
I got a 30lb of 409A if you are interested pm me
-
06-14-2011, 10:59 PM
Thread: Need to figure out Trane model
by chill out hvac- Replies
- 5
- Views
- 426
Not sure what your original question was? It is a...
Not sure what your original question was? It is a 3ton unit you have there.. And American Standard is Trane!
-
06-14-2011, 10:56 PM
- Replies
- 3
- Views
- 282
Shoot some nitrogen in that sucker and bubble...
Shoot some nitrogen in that sucker and bubble everything.. If he is having to add refrigerant every so often, i suspect finding that leak will not be an all day event.
-
06-14-2011, 10:53 PM
Thread: Hey Everyone
by chill out hvac- Replies
- 3
- Views
- 424
Hey Everyone
Hey there new to the site, looking forward to passing on some knowledge and better yet learning from everyone here.. Cheers!