  1. Replies
    24
    Views
    3,641

    Could be an oil logged evaporator.

    Could be an oil logged evaporator.
  2. Replies
    4
    Views
    588

    Common & Run wires

    If the common and the run wires were switched on a single phase compressor would this burn out the windings? We had one supposedly came right from the factory like this and supposedly burned out on...
  3. Replies
    17
    Views
    1,712

    Call Hill York. They have a Dade County and...

    Call Hill York. They have a Dade County and Broward County office. I worked for them for many years but now live in Georgia. I worked for years in the Islands and Hill York had a Nassau branch.
  4. Replies
    34
    Views
    4,253

    If you are ever in the Atlanta area, I am looking...

    If you are ever in the Atlanta area, I am looking for a good Tech.
  5. Replies
    4
    Views
    973

    What kind of problems? You should be using Sch.80...

    What kind of problems? You should be using Sch.80 and anything over 4" you should bevel the pipe end, sand & clean the fitting socket and raw pipe end before you solvent weld (glue) using a heavy...
  6. Replies
    11
    Views
    1,299

    Call in a service tech.

    You should have the performance of your WSHP checked by a qualified service company.
  7. Replies
    7
    Views
    1,049

    Problem Solved

    Reclaimed the refrigerent, repleced the drier and evacuated and weighed in the charge.....67/255 no more hunting on the high side. Had to of been non condensables.
  8. Replies
    7
    Views
    1,049

    I agree with bmac. I would also change the drier....

    I agree with bmac. I would also change the drier. Did you split the coils to wash them?

    Single coil on this one. According to the customer (New customer for me) No one has added refrigerant or...
  9. Replies
    4
    Views
    2,387

    Ductless split

    The gauge ports on the outside of the Cond. are to use for evacuation of the lineset before opening the service valve. there should be service ports inside the condensing unit for pressure check. The...
  10. Replies
    7
    Views
    1,049

    Trane Voyager 20 Ton, (2) 10 Ton Scroll's, 400...

    Trane Voyager 20 Ton, (2) 10 Ton Scroll's, 400 PSI head, cleaned cond. coils and started system back up. 1st stage comp runs 65/245 (Dry Coil) second stage starts and runs 58 Suction and the head...
  11. Thread: Charging

    by acfixit
    Replies
    8
    Views
    1,172

    Charging a system with refrigerant

    "I was showed a couple different ways and was wanting to know the proper way".

    How do you know that you were not shown the proper way to add Refrigerant?
  12. Replies
    156
    Views
    16,988

    Local Union

    LU 72 Atlanta, Ga. Orig. from LU 725 Miami, Fla.
  13. Replies
    22
    Views
    2,423

    Why run another chiller if you have enough...

    Why run another chiller if you have enough cooling capacity instead of running another pump? have you looked at design flow and compared to existing? How about pump head?
  14. Replies
    12
    Views
    847

    Try Joe Powell & Assoc. in Norcross, Georgia ...

    Try Joe Powell & Assoc. in Norcross, Georgia 770-449-4010
  15. Replies
    77
    Views
    45,964

    22 Deg. delta T

    22 Deg does indicate low air flow, You need a pro to come out do a Load Calc, Check the duct work, and the performance of the system...Fan speed? Super Heat, Refrigerant line size...Etc. 571SQ/Ton I...
  16. Thread: refig lines

    by acfixit
    Replies
    4
    Views
    822

    Lineset

    You need to hire a professional to install the lineset. Size is important,Vert. traps if necessary, no kinks...Etc.
  17. Replies
    4
    Views
    1,682

    Actuator

    Call Trane!