Search:

Type: Posts; User: david912

Page 1 of 8 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    7
    Views
    278

    May be a stupid question but were the CCH's...

    May be a stupid question but were the CCH's reinstalled on the new compressors? If so are they working properly? As far as the clean up, have fun. May be a little bit of a challenge getting the...
  2. Replies
    63
    Views
    4,569

    If you really want to get your foot in the door...

    If you really want to get your foot in the door apply on every job they have posted for your area. Thats is the way i Approached it and i got a call, not exactly for the position i was fit for but I...
  3. Replies
    63
    Views
    4,569

    Im not sure about the under review part, i did...

    Im not sure about the under review part, i did not notice that. I got called for an interview, after i got offered the position it took about 3 weeks. My interview was about 4 hours, had to take a 4...
  4. Replies
    7
    Views
    570

    Have you watched you gauges when it trips?? ...

    Have you watched you gauges when it trips?? Those Tranes have a little lockout relay in the board, i would take a look at that scematic!
  5. X2

    X2
  6. Craigslist, never thought about that

    Craigslist, never thought about that
  7. Have you figured anything out on your relocation....

    Have you figured anything out on your relocation. I too am looking to move to N Georgia in the near future
  8. Replies
    9
    Views
    738

    looks like somebody left some coil cleaner on...

    looks like somebody left some coil cleaner on there a bit too long
  9. Replies
    778
    Views
    25,540

    Lol who cares

    Lol who cares
  10. Replies
    778
    Views
    25,540

    My wife just agreed, i dont care either

    My wife just agreed, i dont care either
  11. Replies
    778
    Views
    25,540

    I just ate mexican food. The waitress gave us...

    I just ate mexican food. The waitress gave us gravy instead of queso, although it did look fairly similar. My wife was digging in like is was indeed queso. Oh yea and a lady at another table was...
  12. Replies
    8
    Views
    497

    12* td from inlet to outlet. If you had a water...

    12* td from inlet to outlet. If you had a water flow problem your td would be High. Like Pernderway said, that also leads me to believe overcharge. 12* SH 30* SC sounds like you could be...
  13. Replies
    8
    Views
    497

    I would start by making sure the flare connectors...

    I would start by making sure the flare connectors for your flex lines are not stopped up, and flush the coil out by breaking the outlet loose and running it into a bucket. You would be surprised how...
  14. Replies
    12
    Views
    855

    Did you ever recycle power, it sounds like its...

    Did you ever recycle power, it sounds like its locked out on something. Whats your m# s#
  15. Replies
    6
    Views
    399

    Sounds like they may be buying them a good ol...

    Sounds like they may be buying them a good ol split system lol. I think your on the right track! All your readings lean towards that. 90* inlets pretty high along with your low td's. Mabey a...
  16. Replies
    16
    Views
    1,026

    Your on the right track. Change the module

    Your on the right track. Change the module
  17. Replies
    15
    Views
    949

    I completely agree with not understanding as much...

    I completely agree with not understanding as much as I thought!! If I am reading this right, which I very well may not be. The section I highlighted red seems to me that they are saying dropping your...
  18. Replies
    15
    Views
    949

    Fairly normal. Let it ride, and yes your SH can...

    Fairly normal. Let it ride, and yes your SH can be lower than SC
  19. Replies
    15
    Views
    949

    Condenser coil dirty would cause low to no...

    Condenser coil dirty would cause low to no subcooling
  20. Replies
    21
    Views
    2,706

    We all struggle sometimes, but its how you handle...

    We all struggle sometimes, but its how you handle it that determines what kind of tech you are. None of us are perfect, were all gonna miss things from time to time, but like you said. How can you...
  21. Replies
    21
    Views
    2,706

    Lol. And mike19. Thats pretty bad too, some...

    Lol. And mike19. Thats pretty bad too, some people just dont grasp it
  22. Replies
    21
    Views
    2,706

    I haven't either. the guy said he looked at...

    I haven't either. the guy said he looked at another unit up there and it was borderline too. I bet all of the units are
  23. Replies
    21
    Views
    2,706

    Very true!! This guys good at pulling the wool...

    Very true!! This guys good at pulling the wool over the owners eyes. I started with this company about 3 months ago. I went to help him pull and clean a coil when I first started I asked him if he...
  24. Replies
    21
    Views
    2,706

    how do you overlook this

    Had another tech that was working on a chain store. He comes back to the shop and says one had a contactor bad and one had a broken belt. Well this particular PITA company requires that they send...
  25. Thread: Puzzled

    by david912
    Replies
    22
    Views
    1,646

    Nice cold suction line. Doesent really shed any...

    Nice cold suction line. Doesent really shed any light on anything. Have you checked bearings and amp draw on the cfm. Really dont have enough info to help. An "intermitting metering problem"...
  26. Replies
    22
    Views
    1,117

    You beat me to it. I had to read that twice

    You beat me to it. I had to read that twice
  27. Replies
    22
    Views
    1,672

    LOL Be safe was the disclaimer!

    LOL

    Be safe was the disclaimer!
  28. Replies
    13
    Views
    1,008

    Nothing is Free:grin2: and when your have a heat...

    Nothing is Free:grin2: and when your have a heat pump with electric aux heat, when it get below about 35* all that money you saved by having a heat pump gets sucked up by the heat strips. To me its...
  29. Replies
    2
    Views
    376

    Sent you an email

    Sent you an email
  30. Replies
    40
    Views
    8,909

    My former boss sent me to this school. I got...

    My former boss sent me to this school. I got alot out of it and I believe anyone that went to this school willing to learn and can retain information would benefit from it and have a solid...
  31. Replies
    4
    Views
    802

    Preciate it, i sent you an email zzeck

    Preciate it, i sent you an email zzeck
  32. Replies
    20
    Views
    1,081

    Sounds like it might end up being a txv issue. ...

    Sounds like it might end up being a txv issue. You might post this in one of the chiller sections. You may get more help
  33. Replies
    11
    Views
    615

    I like the east cost im from Georgia and working...

    I like the east cost im from Georgia and working on moving back. I am currently stuck in the desert. if you like water and trees don't go to west texas :grin2:. I like it for the most part other...
  34. Replies
    53
    Views
    2,670

    Did you put the oem board back on in. Or did you...

    Did you put the oem board back on in. Or did you do a rescue or universal board? Are your dipswitches set right, does it have a smartvalve as rundawg suggested? I take it your gettin voltage on...
  35. Replies
    19
    Views
    1,246

    GD huh is that really necessary

    GD huh is that really necessary
  36. Replies
    57
    Views
    9,605

    x2

    x2
  37. Replies
    41
    Views
    1,596

    Removing the bulb should have raised suction and...

    Removing the bulb should have raised suction and lowered SH, which shoul do the opposite of freezing. Your txv should maintain a SH of 10-15 +5/-3. So 7-20 on the SH is tolerable but 10-15 is...
  38. Replies
    41
    Views
    1,596

    Do you have two furnaces with a solid coil across...

    Do you have two furnaces with a solid coil across or 2 separate coils with separate txvs? Are all your distribution tubes feeding? Are all your "u" bends on the coil feeding (cold, sweating). ...
  39. Replies
    66
    Views
    4,131

    This is what i use its 56% i dont know why i...

    This is what i use its 56% i dont know why i thought 35% It works great

    http://m.johnstonesupply.com/storefront/product-view.ep?pID=R56-793
  40. Replies
    66
    Views
    4,131

    Ive brazed in 2 1/8in brass suction valves with...

    Ive brazed in 2 1/8in brass suction valves with the orange fluxed utectic stuff. I think its 35% But with oxy/act for sure. You shouldnt have a problem with oxy/act
  41. Replies
    8
    Views
    540

    Water flow. And did yo weigh in the charge

    Water flow. And did yo weigh in the charge
  42. Replies
    13
    Views
    4,412

    I don't like seeing pookie and aluminum tape...

    I don't like seeing pookie and aluminum tape everywhere.... foam tape in between furnace and coil. I understand it at the top with the ductboard but at least make it where you can get the panel off
  43. Replies
    41
    Views
    1,596

    Even if your Sh is 40* and your suction line temp...

    Even if your Sh is 40* and your suction line temp is 80*. If the dew point is 81* your suction line will be sweating, sooo that dont say much. I would start looking at my txv
  44. Replies
    70
    Views
    6,675

    When I was first getting started, I pumped down a...

    When I was first getting started, I pumped down a ruud unit to pull and clean evap. Got the coil in soldered up went outside to change the drier. I get the ol torch out get to unsweatin the old one...
  45. Replies
    41
    Views
    1,596

    High SH, High SC= restriction

    High SH, High SC= restriction
  46. Replies
    20
    Views
    1,081

    Yes sir keep us posted

    Yes sir keep us posted
  47. Replies
    20
    Views
    1,081

    If the powerhead has been changed, compressors...

    If the powerhead has been changed, compressors have been changed there have been a lot of hands in the system. I would start by pulling the charge and seeing if you come up short. Then you have a...
  48. Replies
    33
    Views
    5,834

    Thank you, ive had guys argue about that on here....

    Thank you, ive had guys argue about that on here. They will say it states it in the installation manual. Well yes it does but it states that the coil is a listed section of heat pump also, and if...
  49. Replies
    20
    Views
    1,081

    What is your Sh Sc With one compressor running?...

    What is your Sh Sc With one compressor running? Is your sight glass clear? This is r-22? Seems like it might be low on refrigerant too me.
  50. Replies
    20
    Views
    1,081

    It wont run long enough with both compressor...

    It wont run long enough with both compressor running to get SH SC.
Results 1 to 50 of 358
Page 1 of 8 1 2 3 4

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event