  1. thanks i will do that - - - Updated - - - ...

    thanks i will do that

    - - - Updated - - -



    Thanks so much
  2. Drain on exhuast had come off, dripping water...

    Drain on exhuast had come off, dripping water onto valve, I repaired that as well. I have it running but still would like to replace the original plug. I am just not having any luck finding it.
  3. honeywell smart valve on tempstar, burnt plug.

    Last night on a no heat call found bad smart valve. The inducer fan plug on the tempstar had melted. Replaced valve but the plug from furnace couldnt be fixed. My question is where do I find the 4...
  4. Thanks, beginning to think that as well.

    Thanks, beginning to think that as well.
  5. Head pressure stays at 150, suction drops. Will...

    Head pressure stays at 150, suction drops. Will not run long enough for superheat or subcooling. House is 4 years old, did find out the outdoor unit was stolen before they bought it ( left lines...
  6. american standard cycling on low pressure

    I have a unit that is messing with my head. American standard cutting off with low suction pressure, whether the reversing valve is energized or not. Hard to diagnose because it will not run. As soon...
  7. Replies
    2
    Views
    1,328

    heatmaster log problem

    I am working on a set of logs that i can get the pilot to light but when i try to turn on to burners it cuts completly down. Shuts pilot off, i can hear the valve. It has a thermocouple and...
  8. Replies
    7
    Views
    519

    I am not second guessing, i know how to hook up...

    I am not second guessing, i know how to hook up compressor plus can read a wiring diagram. I am simply asking a question.
  9. Replies
    7
    Views
    519

    The compressor side of split capacitor. I ran to...

    The compressor side of split capacitor. I ran to start, he insisted to hook up at run. I am not trying to be confusing. The common is correct at compressor but basically start and run backwards.
  10. Replies
    7
    Views
    519

    bad compressor

    I helped someone change out a compressor today. I brazed out old comp. and set new one, pressure tested and started to pull vacuum. I wired correctly but he insisted that the herm wire off the cap....
  11. Replies
    4
    Views
    474

    Sounds like it may be cycling on limit switch and...

    Sounds like it may be cycling on limit switch and not stat. Get the professional back out. Explain it is never reaching set temperature. It may operate different but it should reach 70 degrees.
  12. Replies
    27
    Views
    4,240

    I agree maybe a little too much dope, and yes...

    I agree maybe a little too much dope, and yes shoulda recut for a solid piece. But all in all i think it looks good. Lord knows the crap i have seen.
  13. Replies
    27
    Views
    4,240

    Floor valves arent required in my county, just a...

    Floor valves arent required in my county, just a shut off, there is one easily accessible in the box itself. Yeah i d rather have too much pipe dope than not enough.
  14. Replies
    27
    Views
    4,240

    Gas piping (hard pipe)

    10390

    10392

    10393

    10394

    10395
  15. Replies
    2
    Views
    453

    condenser motor

    I changed a condenser motor on a 3 1/2 ton 12 seer tempstar about 6 months ago. About 2 months ago got a call. The motor was making a horrible racket. It acted like the bearing was bad so i replaced...
  16. it sounds like they havent really found the...

    it sounds like they havent really found the problem. Did they do a nitrogen check when they changed coil? Maybe still a leak.
  17. Replies
    21
    Views
    1,405

    You can take the front off the stat and see if...

    You can take the front off the stat and see if there is a y2. if not it isnt going into second stage.
  18. Replies
    8
    Views
    815

    Dual fuel may not be a bad idea. may offset price...

    Dual fuel may not be a bad idea. may offset price of wire and new breaker.
  19. Replies
    15
    Views
    1,652

    Are you sure it isnt screwed on the inside? Seems...

    Are you sure it isnt screwed on the inside? Seems like the filter, plenum, ductwork sure would be heavy for tape and mastic to hold up. On the door make sure the filter rack is square. The doors are...
  20. Replies
    7
    Views
    2,285

    it is not two stage cooling, only 16i and 19i....

    it is not two stage cooling, only 16i and 19i. You may still use variable speed though.
  21. Replies
    291
    Views
    14,333

    had to pull blower motor,not tightened on shaft....

    had to pull blower motor,not tightened on shaft. v/s pigtail not plugged in. wires not in harness on 16i. reversing valves banging. look at a weathertron from last year and now tops are much more...
  22. Replies
    291
    Views
    14,333

    i have been having more problems out of them...

    i have been having more problems out of them lately. simple things, but i shouldnt have to troubleshoot new eqp.
  23. Replies
    291
    Views
    14,333

    Tessmer, just to satisfy my own self, what brands...

    Tessmer, just to satisfy my own self, what brands to you install or suggest?
  24. Replies
    291
    Views
    14,333

    In my opinion goodman is a good product and it...

    In my opinion goodman is a good product and it has a 10 yr. warranty. I also like the lennox units, they are nice products. Trane well i have been having a little problem (minor yet problems) with...
  25. Thread: installation

    by jeremydp
    Replies
    4
    Views
    526

    I use line hide. Good sleak look.

    I use line hide. Good sleak look.
  26. Replies
    12
    Views
    933

    Is it unethical or is it good,sound advice?

    Is it unethical or is it good,sound advice?
  27. Replies
    12
    Views
    933

    I did not think is was worth fixing on a 20 yr....

    I did not think is was worth fixing on a 20 yr. old system, though might run into further problems. But i am basically still a newbie and thats why i asked. Thanx for the input, i will hunt that leak...
  28. Replies
    12
    Views
    933

    boards oppinions.

    I recently had a no cooling call. Found very low on charge and just been charged up last week. I then explained the options of just changing system out. It is a 20 yr. old tempstar. She said that the...
  29. Replies
    2
    Views
    539

    superheat in air conditioning.

    superheat in air conditioning.
  30. Replies
    10
    Views
    826

    Regulator has vent limiter. shuts off. Other than...

    Regulator has vent limiter. shuts off. Other than that all kinda wrong.
  31. Replies
    8
    Views
    749

    You are correct. You should replace both. But if...

    You are correct. You should replace both. But if a customer has limited funds, do what you have to do. Your efficiency will not be as rated. And i believe through my experience your pressures will be...
  32. Replies
    8
    Views
    752

    All of the responses will be very helpful. I have...

    All of the responses will be very helpful. I have been going through different things in my mind. I will keep yall posted.
  33. Replies
    8
    Views
    752

    whats up with this?

    At a unit today, cust. says 6 yrs. old, one changed compressor nothing else ever serviced. He is just not comfortable in home( 96 yesterday) well bet no one has had this. 6 year old Tempstar outdoor...
  34. Replies
    8
    Views
    955

    I would shut heat pump at around 40, keep it out...

    I would shut heat pump at around 40, keep it out of defrost.
  35. Thread: honeywell

    by jeremydp
    Replies
    9
    Views
    1,187

    honeywell

    I have an phone interview with honeywell for an hvac mechanic technician. Just wondering if anyone had any experience with them. thanx.
  36. Replies
    4
    Views
    669

    At the company i work for i do the control wiring...

    At the company i work for i do the control wiring and start ups. We install a honeywell touchscreen t stat. pull a 2 wire t stat wire from stat to outdoors, and hook up to s1 and s2. The other...
  37. Replies
    3
    Views
    698

    new job questions

    I currently work as a start up tech for a fairly large hvac company. I have expressed interest in moving into the service dept. I was told get epa( which i already have) Certificate from tech school...
Results 1 to 37 of 58