Search:

Type: Posts; User: primmers

Page 1 of 20 1 2 3 4

Search: Search took 0.02 seconds.

  1. Replies
    48
    Views
    1,936

    icemeister it wasn't that nice..Ill see if I can...

    icemeister it wasn't that nice..Ill see if I can get a picture of it.
  2. Replies
    48
    Views
    1,936

    I had the line set out on the back steps to pre...

    I had the line set out on the back steps to pre solder the fittings and we just went ahead and soldered the liquid line (every foot or so) to the suction line..Im not sure how Hussmann had it...
  3. Replies
    25
    Views
    870

    I have a electronic super heat tool and it and my...

    I have a electronic super heat tool and it and my gauge set are 10* off.
  4. Replies
    3
    Views
    281

    ararams and icemeister

    These guys stuck with me with a problem I was having with a old Hussmann deli case..

    Came up with a possible solution, and it was the problem..

    Thank you guys soooo much, now I can get a decent...
  5. Replies
    48
    Views
    1,936

    ararams and icemeister it was the heat...

    ararams and icemeister it was the heat exchanger, I pulled the old one out fabricated a new and walla..it works now..

    thank you so much..
  6. Replies
    48
    Views
    1,936

    I know, and thats what I told my competitor..but...

    I know, and thats what I told my competitor..but he swears thats what he was told..

    I couldn't get a clear sight glass until i used up 40+ lbs..I know thats way too much…

    As I said Im more...
  7. Replies
    48
    Views
    1,936

    Im going back to the system, I just need to put a...

    Im going back to the system, I just need to put a couple fires out…..I had a competitor that I work with tell me
    he was told by his copeland rep that clearing a sight glass isn't important on a head...
  8. Replies
    10
    Views
    1,655

    aea4440y found it online

    aea4440y found it online
  9. Replies
    10
    Views
    1,655

    Anyone know what the model number is for the...

    Anyone know what the model number is for the compressor for this unit??
  10. Replies
    48
    Views
    1,936

    I hate to jinks myself but the case is running,...

    I hate to jinks myself but the case is running, with out a cleared sight glass I might add…Ive always cleared one with a head master valve,,

    all I did was replace the pump down solenoid, inspect...
  11. Replies
    48
    Views
    1,936

    Im assuming the heat exchanger is in the...

    Im assuming the heat exchanger is in the case..Ill look this morning..
  12. Replies
    48
    Views
    1,936

    The guy that make the TXV said it was 1.5-2 ton.....

    The guy that make the TXV said it was 1.5-2 ton.. Q - the element is a KT43SZP..My paper work says BQCB cartridge..


    *gulp*
  13. Replies
    48
    Views
    1,936

    The pump down solenoid is bad, won't pump down...

    The pump down solenoid is bad, won't pump down Ill be replacing it in the afternoon….
  14. Replies
    48
    Views
    1,936

    the honey comb is about 2" thick and its open,...

    the honey comb is about 2" thick and its open, but I did blow it out and got some trash..

    The thing Im thinking now is is putting a different fan blade to draw more air..

    theres a slight air...
  15. Replies
    48
    Views
    1,936

    No air movement at all….Im wondering if I have...

    No air movement at all….Im wondering if
    I have oil in the evaporator now??

    no superheat to speak of no temp differential…..in the evap.
  16. Replies
    48
    Views
    1,936

    I will pull the honey combs tomorrow and spit...

    I will pull the honey combs tomorrow and spit shine them.. the coil looks good, almost new..

    thanks for all the help guys…
  17. Replies
    48
    Views
    1,936

    I just came back from the system…the return vent...

    I just came back from the system…the return vent ( knee high ) can suck a plastic produce bag, how ever up above,, not much..the honey comb seems to be clean.. I need to replace the pump down...
  18. Replies
    48
    Views
    1,936

    This is a open deli case, 12' long, and I hate...

    This is a open deli case, 12' long, and I hate it. Evap and fans are on top.
  19. Replies
    48
    Views
    1,936

    The honey comb looks dirty but we blew it out, I...

    The honey comb looks dirty but we blew it out, I can hardly feel any air at all//but its clean and all 3 fans are doing their job..

    I don't have a fpm tool..I didn't see any frost on the outlet of...
  20. Replies
    48
    Views
    1,936

    ALSO..the pump down solenoid on the liquid live...

    ALSO..the pump down solenoid on the liquid live next to the TEX…it won't shut off, I can hear it click when going form 35 to 90*, but it seems its leaking..would that have an affect on the super heat...
  21. Replies
    48
    Views
    1,936

    I think Im in trouble….I installed a new...

    I think Im in trouble….I installed a new condenser (30,800 btu, TEHA035E6HS2BB) new TEV valve and element KT-43-SC, line set and P-trap)

    I can't get any compressor superheat…it runs between 7-10...
  22. Im going to bite the bullet and travel the 400...

    Im going to bite the bullet and travel the 400 miles round trip. Pecmsg's comment about the suction filter scared me..

    Sometimes it sucks living in the middle of nowhere…..but only sometimes..

    ...
  23. Thanks all……

    Thanks all……
  24. I would be buying the "other" copper from a...

    I would be buying the "other" copper from a plumbing supply house. Thanks
  25. Urgent……..suction line copper question

    Im installing a new condensing unit, had to relocate it outside from under the building..
    I bought 30 feet of 1 ⅛ copper for the suction line…Im gona be short maybe another 30'…

    The closest...
  26. Replies
    48
    Views
    1,936

    This is for the hussmann deli case I mentioned...

    This is for the hussmann deli case I mentioned above..Hussman spec'd out the condensing unit.
  27. Replies
    48
    Views
    1,936

    icemeister..I have another question..Im...

    icemeister..I have another question..Im purchasing a condensing unit that has a ⅜ liquid and ⅞ suction the old system was plumbed with ˝ and 1' lines. Condensor is below the case maybe 6 foot drop...
  28. Replies
    48
    Views
    1,936

    Thanks Icedude, Ill copy that and put it in my...

    Thanks Icedude, Ill copy that and put it in my "stuff to know" file..
  29. Replies
    48
    Views
    1,936

    Yes the evap is on the top and it looks to have a...

    Yes the evap is on the top and it looks to have a honey comb thing thats probably filthy..
  30. Replies
    48
    Views
    1,936

    old hussman question

    Customer has a deli case Mo# B9D-12ZBU, Ser # 8235-5909.

    I replaced the TXV that was in the case (no adjustment) it was a 1 ton valve..I ordered a replacement and still had no adjustment, I closed...
  31. Replies
    29
    Views
    1,333

    i love this site..

    i love this site..
  32. Thread: Stupid Forum

    by primmers
    Replies
    60
    Views
    2,094

    Radical Mancow???

    Radical Mancow???
  33. Replies
    63
    Views
    5,150

    I just seen a Norlake 2 door reach in cooler..it...

    I just seen a Norlake 2 door reach in cooler..it sure looked like a Turboair the controller and all.
  34. Replies
    63
    Views
    5,150

    replacement compressors don't fit either, I had...

    replacement compressors don't fit either, I had to bend the crap out of the sheet metal to get one to slid in..
  35. Replies
    63
    Views
    5,150

    Im glad Im not the only one that thinks turbo...

    Im glad Im not the only one that thinks turbo airs are crap,,how about arctic air,,I think its the same company.
  36. Replies
    63
    Views
    5,150

    Thanks skpkey9 thats what i wanted..

    Thanks skpkey9 thats what i wanted..
  37. Replies
    63
    Views
    5,150

    I did some warranty work for True in exchange for...

    I did some warranty work for True in exchange for their service manual..I never received it..
  38. Replies
    9
    Views
    1,979

    UmmScott, Im the one that brought it back, but I...

    UmmScott, Im the one that brought it back, but I was talking a commercial machine..

    But I have told a customer with a trash compactor to throw it away..he did and bought the exact same...
  39. Replies
    9
    Views
    1,979

    Seems I was told a soft water system is tough on...

    Seems I was told a soft water system is tough on a ice machine,,I have a customer that I recommended them doing it and they did, the water quality is good but the ice looks crappy (cloudy and soft)....
  40. Replies
    34
    Views
    2,205

    ICanHas, Im one of 15 guys doing this work, Im a...

    ICanHas, Im one of 15 guys doing this work, Im a one man show, and Im the busiest of them all, I was working 7 days a week, Im down to 5 because Im old..Im pretty sure Im busy because I treat my...
  41. Replies
    34
    Views
    2,205

    ICanHas, aint America great??? we still a couple...

    ICanHas, aint America great??? we still a couple rights, and some will use those "rights" to screw you and ME..
    I don't have any respect for a person that will let you do a days work and not pay...
  42. Replies
    34
    Views
    2,205

    In California, you go to court and the judge if...

    In California, you go to court and the judge if he sides with the contractor, will tell the dead beat to pay, if he doesn't, then its all over again…
  43. Replies
    34
    Views
    2,205

    Sometimes I forget that political correctness...

    Sometimes I forget that political correctness thing..my bad..
  44. Replies
    34
    Views
    2,205

    One was a dead beat that screwed all his vendors,...

    One was a dead beat that screwed all his vendors, now is a cash only customer by his vendors, (not me I won't do any more for him).

    the other was a guy that was in the middle of selling his...
  45. Replies
    34
    Views
    2,205

    Im not saying its legal but I don't have the time...

    Im not saying its legal but I don't have the time to go to court to have a judge tell my excustomer to pay me and he still doesn't.
  46. Replies
    34
    Views
    2,205

    Ive gone back and got my stuff, and then there is...

    Ive gone back and got my stuff, and then there is one guy Im waiting to find on the side of the road broke down..he won't be coming home for dinner.
  47. Replies
    12
    Views
    874

    Poodle Head, you're screwing the chinese workers...

    Poodle Head, you're screwing the chinese workers by buying American made products, I hope you cant live with yourself.
  48. Replies
    12
    Views
    874

    thanks guys..

    thanks guys..
  49. Replies
    168
    Views
    14,541

    EMETH, a .22 will kill you, imagine getting a...

    EMETH, a .22 will kill you, imagine getting a medium sized phillips screw driver stuffed in your temple or heart, you're going down for the count.

    When i was in high school, a kid shot another kid...
  50. Replies
    3
    Views
    598

    I hate turbo airs..didnt they change there name??

    I hate turbo airs..didnt they change there name??