Search:
Type: Posts; User: Den-Batch
Search: Search took 0.01 seconds.
-
12-28-2011, 08:53 PM
Thread: plugged captubes
by Den-Batch- Replies
- 26
- Views
- 1,300
High condensing temp causes waxing in the cap...
High condensing temp causes waxing in the cap tube restricting it. If I work on a 134a system that is not keeping temp and find the condenser plugged or the condenser fan burnt out I usually end up...
-
12-25-2011, 08:23 PM
Thread: oven flame
by Den-Batch- Replies
- 3
- Views
- 454
Thermostat might be stuck in bypass.
Thermostat might be stuck in bypass.
-
11-02-2011, 08:42 PM
- Replies
- 14
- Views
- 1,571
Sounds to me like the booster heater is full of...
Sounds to me like the booster heater is full of scale.
-
06-14-2011, 08:30 PM
Thread: mixing cap tube and TXV
by Den-Batch- Replies
- 4
- Views
- 701
I have worked on many of these units. They use...
I have worked on many of these units. They use tev's now and every time I run into a older one with a restricted cap tube I install a tev instead. I think they use a 1/4 ton internal equalized...
-
03-16-2011, 08:50 PM
- Replies
- 27
- Views
- 2,522
I work on a lot of critically charged units and...
I work on a lot of critically charged units and usually when you charge by the data plate and the back pressure is still low it is because the cap tube is partially restricted. Many techs will just...
-
03-01-2011, 09:15 PM
Thread: Frymaster Computer Magic
by Den-Batch- Replies
- 16
- Views
- 4,072
I would say either one of the flame sensors or...
I would say either one of the flame sensors or one of the ignition modules. I would start with 2 flame new sensors. I don't think it is a computer problem, usually when a computer goes bad and says...
-
02-14-2011, 06:47 PM
Thread: reach-in upright cooler
by Den-Batch- Replies
- 3
- Views
- 528
Hobart puts a s shape on the end of the...
Hobart puts a s shape on the end of the thermostat cap tube then inserts it in the middle of the coil. On a few units there are stand off brackets that hold a 3/8 copper tube and the cap tube goes...
-
02-07-2011, 08:45 PM
Thread: Whos the manufacture?
by Den-Batch- Replies
- 7
- Views
- 434
Did you melt the frost I see? It might be under...
Did you melt the frost I see? It might be under that.
Results 1 to 8 of 8