Search:
Type: Posts; User: mrfixitright
Search: Search took 0.01 seconds.
-
10-08-2012, 09:01 PM
Thread: amana trouble
by mrfixitright- Replies
- 6
- Views
- 483
amana trouble
Got a amana that when it lights it fires off and then stops then lights again, all within a second, i am not losing power to gas valve nor am i losing manifold pressure, has a new ignitor, it makes...
-
01-14-2012, 07:30 AM
Thread: journeyman exam
by mrfixitright- Replies
- 5
- Views
- 667
What is the best way to study for it, wish they...
What is the best way to study for it, wish they had a practice exam
-
01-11-2012, 07:31 AM
Thread: High Limit Still Tripping
by mrfixitright- Replies
- 53
- Views
- 2,593
I had the same problem before, found out the heat...
I had the same problem before, found out the heat exchanger and secondary was dirty inside, pulling alot of dirt in from intake. Took everything apart and used nitrogen and a vaccum to clean it, has...
-
01-10-2012, 06:19 AM
Thread: journeyman exam
by mrfixitright- Replies
- 5
- Views
- 667
journeyman exam
Is there any one from Iowa on here that has taken the Iowa test for the state license for hvac
-
12-14-2011, 06:53 AM
- Replies
- 14
- Views
- 2,796
On the lennox units I found for me it is best the...
On the lennox units I found for me it is best the take out the rubber tee and use a socket but others may disagree
-
12-05-2011, 06:18 AM
Thread: payne furnace
by mrfixitright- Replies
- 7
- Views
- 571
We put bothof them in, i think, but i dont see...
We put bothof them in, i think, but i dont see why it has any thing to do with who installed it, they both ran fine for 2 days. I removed them collector box and pulled all those pieces out (sorry...
-
12-04-2011, 06:06 AM
Thread: payne furnace
by mrfixitright- Replies
- 7
- Views
- 571
payne furnace
Inthe past 2 weeks i have found 2 payne furnaces with plugged sec. heat exchangers, both were put in 2 days prior to the nobheats. The substance i cleaned out was a white pasty material. Any ideas.
-
11-27-2011, 07:42 AM
- Replies
- 44
- Views
- 1,459
just suck it up,
just suck it up,
-
11-27-2011, 07:38 AM
- Replies
- 44
- Views
- 1,459
If you dont know when it happened how are you...
If you dont know when it happened how are you going to fill out a report, you need dates on those, and you need to go tothe doctor and have a pro check it out, without a doctors consent you wont get...
-
11-18-2011, 06:38 AM
Thread: Water in inducer motor
by mrfixitright- Replies
- 28
- Views
- 2,217
Like I said (on some units)lennox, g26 there is a...
Like I said (on some units)lennox, g26 there is a spot for the hole to be drilled,it comes with a kit, you seal in with a hose clamp and you dont have to worry about water on the board. If someone...
-
11-17-2011, 07:30 AM
Thread: Water in inducer motor
by mrfixitright- Replies
- 28
- Views
- 2,217
On some units, you can drill a hole at the bottom...
On some units, you can drill a hole at the bottom of the combustion blower and put a hose there going to the drain but make sure it is looped. I believe it is a 3/8 hose
-
11-12-2011, 06:26 AM
Thread: Lennox Pulse Circuit Board?
by mrfixitright- Replies
- 3
- Views
- 504
the box with the ignition wires from it is the...
the box with the ignition wires from it is the circut board, either white, green, black, or blue in color
-
11-08-2011, 08:29 PM
Thread: Lennox furnace problem
by mrfixitright- Replies
- 5
- Views
- 598
The welds on the boards that hold theheat relay...
The welds on the boards that hold theheat relay in play sometimescome lose may need to wiggle itaround to check
-
11-08-2011, 08:25 PM
- Replies
- 15
- Views
- 1,050
Had on doing the same thing about a month ago. ...
Had on doing the same thing about a month ago. Did u take off combustion blower and make sure there was not a bird in there.
-
11-05-2011, 08:28 AM
Thread: Lennox Pulse
by mrfixitright- Replies
- 8
- Views
- 649
check the air flapper u can usualy clean them,...
check the air flapper u can usualy clean them, and take a micro amp signal should be up around 5 to 7. If thedrip leg has never been cleaned then cut it and clean it.
-
11-02-2011, 09:04 PM
Thread: using dollar bill to clean igniter
by mrfixitright- Replies
- 36
- Views
- 2,425
A dollar is the best thing to use for a flame...
A dollar is the best thing to use for a flame sensor, but i have never herd of cleaning a ignitor.