  1. That is some of the stainless steel solar ...

    That is some of the stainless steel solar
    piping I had left. It is expensive but can handle the temp, figured waste wasn't in my vocabulary
  2. The king span solar is the primary heating source...

    The king span solar is the primary heating source for the 80 gallon indirect water heater. Tank is kept at 180 degrees and mixed down. The boiler backs up domestic and does all of the baseboard heat...
  3. triangle tube boiler with solar hot water in a basement

    302831302841302851302861302871302881
  4. Replies
    11
    Views
    2,211

    nice avatar, i have 4 of those on my resume. the...

    nice avatar, i have 4 of those on my resume. the altherma is a good choice and with a estimated 1,000.00 per year for heat, a/c, and hot water doesn't sound bad either.
  5. Replies
    11
    Views
    2,211

    none but a lot of preliminary research and i got...

    none but a lot of preliminary research and i got my hands on the altherma commisioning, install manual.
  6. Replies
    11
    Views
    2,211

    i must have missed that pic for uploading but i...

    i must have missed that pic for uploading but i will post it. the solar hot water is amazing, the altherma never runs! 41 degree chilled water to the hydro takes care of the house very easy, and...
  7. Replies
    11
    Views
    2,211

    Thanks, yes he did, but went with this option due...

    Thanks, yes he did, but went with this option due to lack of space for loops and full modulation of compressor.
  8. Replies
    11
    Views
    2,211

    The hydro box to the left has its own built In...

    The hydro box to the left has its own
    built In pan, and I didn't feel the tank needed one being in a garage.
  9. Replies
    11
    Views
    2,211

    299411[

    299411[
  10. Replies
    11
    Views
    2,211

    diakin altherma with solar hot water

    this system was a blast to install. and it won't be the last one.299291299301299311299321299331299341299351299361299371299381
  11. Replies
    16
    Views
    3,760

    Ialso agree with stamas on this one.

    Ialso agree with stamas on this one.
  12. my christmas bonus is that I got my first...

    my christmas bonus is that I got my first employee since starting my business. I have been lucky to be in this position and i do consider myself very blessed to pick up a person that loves to learn....
  13. Replies
    4
    Views
    1,211

    i own a 330-1 and bought it in 2005, i have used...

    i own a 330-1 and bought it in 2005, i have used both meters, i am not sure if the 327 will allow you to store your combustion readings. if i was looking again i would be looking at the 330-2 due to...
  14. sorry maniak for the late response ( heating...

    sorry maniak for the late response ( heating season blues) That is a good question, I guess I thought they looked better that whay or easeir to run the mc cable, this is for my home so I wasn't as...
  15. munchkin with indirect and aqua coils

    Not sure if I ever posted this but here it is.62762
  16. Replies
    3
    Views
    931

    oil fired boiler

    62732 this boiler was running when I arived
  17. 62722 looks like this is becoming an epidemic

    62722 looks like this is becoming an epidemic
  18. I have had the testo 330-1 for about 3 seasons...

    I have had the testo 330-1 for about 3 seasons and no problems. It's good to be able to look at the stats from the year before when your at the same customer. I had mine with me at nci running next...
  19. Replies
    6
    Views
    803

    chauncy I use a 1500 watt that I got from sams...

    chauncy I use a 1500 watt that I got from sams club for 99.00 and has done great.I have a deisel eith two batteries a d it is wired directly to them.I also have a bench grinder that it...
  20. Replies
    24
    Views
    5,015

    I'm not sure which model furnace that is and what...

    I'm not sure which model furnace that is and what problems 2 hot is having,but some goodman furnaces have a tesp of .3 and with the coil (assuming a wet coil static of .2-.3" wc) doesn't give you a...
  21. I was curious if the yellow jackets read microns?...

    I was curious if the yellow jackets read microns? I was looking at the testo 560 4-valve with 4-temp ports and microns to 80. It has space for 40 t-p charts also. It's just not cheap and like someone...
  22. Replies
    11
    Views
    2,672

    actually this was the homeowners home and about 6...

    actually this was the homeowners home and about 6 yrs old ,this boiler didn't even have a chance from the start.The chimney was packed solid,had to use an army shovel.filled 2-5 gallon buckets!!
  23. Replies
    17
    Views
    1,521

    milwalkee 13 amp super sawzall with rotating...

    milwalkee 13 amp super sawzall with rotating handle,orbital and staight cut for all thread .works great but pricey.but these are tools(toys)we work with every day.
  24. Replies
    11
    Views
    2,672

    maybe if you live in delaware?

    maybe if you live in delaware?
  25. Replies
    11
    Views
    2,672

    http://img480.imageshack.us/img480/5618/sheppardjo...

    http://img480.imageshack.us/img480/5618/sheppardjob4kz6.jpg http://img480.imageshack.us/img480/2591/sheppardjob5mt9.jpg ...