Search:

Type: Posts; User: jon harmon

Page 1 of 2 1 2

Search: Search took 0.01 seconds.

  1. Replies
    12
    Views
    1,272

    tlp261- enlighten me on that particular line of...

    tlp261- enlighten me on that particular line of Honeywell control
  2. Replies
    8
    Views
    823

    Shaded-great info listed there. I was playing...

    Shaded-great info listed there. I was playing around with some of the free stuff last night.

    Carnak-located in Indy.
    Ventilation air at 20cfm/person x 1500 people=30,000cfm
    That will be max...
  3. Replies
    12
    Views
    1,272

    I am located in Indianapolis I want to use...

    I am located in Indianapolis

    I want to use these to control a project that I am bidding on. Basically it will control 5 to 6 air rotation units, a direct fired mua, some exfiltration fans and the...
  4. Replies
    12
    Views
    1,272

    I am looking to pick up a line of moderately...

    I am looking to pick up a line of moderately priced building controls and am looking into Basys. Anyone with comments on this product line? How is there service, are they responsive to you and your...
  5. Replies
    8
    Views
    823

    Carnak- I will request those calcs from the...

    Carnak- I will request those calcs from the engineer as well. I am giving a budget number for installation to the customer based on preliminary load calcs furnished by the equipment manufacturer. I...
  6. Replies
    8
    Views
    823

    I am looking for calcs for a project that I am...

    I am looking for calcs for a project that I am bidding. It is a totally open pre-engineered metal building (157,000 Sq. Ft.) with an average ceiling height of 34 feet.

    Let me be clear about this....
  7. Thread: Terminology

    by jon harmon
    Replies
    2
    Views
    941

    Anyone interested in giving a tutorial on the...

    Anyone interested in giving a tutorial on the different communication types i.e. Lonworks vs. Bacnet etc...
    Who uses what? If a system is lon can it communicate with a different Manufac. as long as...
  8. Replies
    2
    Views
    1,701

    ACJourneyman I wish it were that easy. The way...

    ACJourneyman I wish it were that easy. The way I understand it the CT is a Trane component or at least their approved vendor. It does not actually control the vanes on the CVHE it only is in there...
  9. Replies
    9
    Views
    1,089

    I agree with the others. Demand a detailed ISO...

    I agree with the others. Demand a detailed ISO or walk away. How many tons are we talking about?
  10. Replies
    2
    Views
    1,701

    I have a serious problem with this Chilltroll. ...

    I have a serious problem with this Chilltroll. Is there anyone who is familiar with them? I will list a brief description of what is(or is not) happening.
    1.) Chilltroll controls an older CVHA and...
  11. Replies
    15
    Views
    3,355

    Be careful not to bite off more than you can...

    Be careful not to bite off more than you can chew. Order a stop major for your machine, it is worth the cost. I would highly recommend having Carrier do the winter service so you can observe. I...
  12. Replies
    9
    Views
    744

    Slimwoodie I think your a little full of...

    Slimwoodie I think your a little full of yourself. It is not rocket science to set up a power burner. I fully understand the consequences of an improperly set up power burner, that is why I asked...
  13. Replies
    8
    Views
    1,247

    I would be inclined to think it is a function of...

    I would be inclined to think it is a function of initial cost -vs- longevity of the system. I certainly am not an engineer but I would suspect energy and maint. costs are higher with unitary as...
  14. Replies
    16
    Views
    3,013

    Hey utcared, I also spent time with Carrier...

    Hey utcared, I also spent time with Carrier Commercial Service. That was my first exposure the Vac-U-Guage as well. I used mine with outer shell cracked/even with a chunk of the glass missing. As...
  15. Replies
    4
    Views
    724

    deanmachanic Thanks for the reply. As to my...

    deanmachanic Thanks for the reply. As to my quals, I am a UA journeyman service tech. I completed a check of all safeties including a pilot turndown test. I just have not done a lot of anylizing...
  16. Replies
    16
    Views
    3,013

    Will a wet bulb indicator work on an aborber?

    Will a wet bulb indicator work on an aborber?
  17. Replies
    4
    Views
    724

    I need a crash course in combustion anylization. ...

    I need a crash course in combustion anylization. I have to set up a power burner with an anylizer but have not had the opportunity to go to school as of yet. I asked this question under the post...
  18. Replies
    9
    Views
    744

    oil2-4-6-gas I am in Indianapolis. Any help...

    oil2-4-6-gas I am in Indianapolis. Any help would be greatly appreciated.
  19. Replies
    9
    Views
    744

    Slimwoodie- I didn't change the motor. The...

    Slimwoodie- I didn't change the motor. The controller was bad leaving the motor in low fire position. Probably a previous contractor or a maint. guy had set the firing rate up to provide sufficient...
  20. Replies
    9
    Views
    744

    Anyone have contact info for a Cyclotherm boiler....

    Anyone have contact info for a Cyclotherm boiler.
    S/N 25492
    Type CW35-N-SP
    MBH 3350

    I am wanting to set the burner back up to spec's. The original Series 90 control for hi/lo fire was bad and ...
  21. Replies
    11
    Views
    1,714

    Why are you going to an automatic reset?

    Why are you going to an automatic reset?
  22. Replies
    28
    Views
    1,947

    or possibly a vacuum break as opposed to the...

    or possibly a vacuum break as opposed to the legendary vacuun type
  23. Replies
    28
    Views
    1,947

    Is there a vacuun break on this exchanger?

    Is there a vacuun break on this exchanger?
  24. Replies
    2
    Views
    935

    I have 4 Sellers boilers at an apartment complex....

    I have 4 Sellers boilers at an apartment complex. There is no info on these boilers. The model #C125W it is a hot water boiler with inshot type burners. This is the first time I have seen this...
  25. Replies
    2
    Views
    1,519

    Hey guys, I have a series 90 control and...

    Hey guys, I have a series 90 control and wondereing how to go about calibrating the stat. It is driving a 9185D1004 actuator (spring return) for the heat valve. THe actuator does stroke open on a...
Results 1 to 25 of 41
Page 1 of 2 1 2