Search:

Type: Posts; User: jtrammel

Page 1 of 18 1 2 3 4

Search: Search took 0.12 seconds; generated 8 minute(s) ago.

  1. Replies
    20
    Views
    202

    Probably, if it were working correctly. Without...

    Probably, if it were working correctly. Without an accurate load calculation it's impossible to say.
  2. Replies
    20
    Views
    202

    Sounds more like a 2.5 ton load to me. You have...

    Sounds more like a 2.5 ton load to me. You have similiar summer weather to my area and I cool my 1800sqft 1980s house with 2.5 tons no problem.
  3. Replies
    3
    Views
    65

    You've got to change your avatar, that's Mr....

    You've got to change your avatar, that's Mr. Bill's avatar.

    I'd guess 20-25/hr
  4. Thread: quoting posts

    by jtrammel
    Replies
    19
    Views
    398

    Just start your reply in front of the post you're...

    Just start your reply in front of the post you're replying to where is says QUOTE=
  5. Replies
    6
    Views
    99

    Those are a cheap way to duct an open space....

    Those are a cheap way to duct an open space. http://www.ruskin.com/file/model/639~Concentric-Diffusers/doc/5653
    I wouldn't suggest trying to take off anything other branch lines. Sell them a...
  6. Thread: 410

    by jtrammel
    Replies
    62
    Views
    1,387

    We should rename this thread the misinformation...

    We should rename this thread the misinformation thread.
  7. Replies
    9
    Views
    162

    Yes .5 ESP is rare, usually find .7-over 1" in...

    Yes .5 ESP is rare, usually find .7-over 1" in the field on furnace/evap coil set ups.
  8. Replies
    5
    Views
    207

    The water itself in the drain line is cold and...

    The water itself in the drain line is cold and will make the pipe sweat. It's code here to insulate horizontal drain line runs in an attic.
  9. Replies
    4
    Views
    156

    I just blow through with nitro and connect them...

    I just blow through with nitro and connect them with a flare coupling.
  10. I thought dad got rid of that rating thing. I'm...

    I thought dad got rid of that rating thing. I'm 98% of the time on htalk my phone and I can't see likes/dislikes or the hierarchy thingy anyways.
  11. Thread: Txt

    by jtrammel
    Replies
    24
    Views
    395

    IS THE TXV ADJUSTABLE!?!

    IS THE TXV ADJUSTABLE!?!
  12. Replies
    9
    Views
    537

    Hi nick, hey Christina. I found some duct leaks...

    Hi nick, hey Christina. I found some duct leaks but no worries, I got it sealed up for you.
  13. Replies
    1
    Views
    141

    4 tons and yes it's likely a rated match for a...

    4 tons and yes it's likely a rated match for a 3.5 ton outdoor unit.
  14. You may need a new coil because it's leaking...

    You may need a new coil because it's leaking refrigerant, not because it's restricted.
  15. Thread: Txt

    by jtrammel
    Replies
    24
    Views
    395

    Is the txv adjustable?

    Is the txv adjustable?
  16. Thread: Txt

    by jtrammel
    Replies
    24
    Views
    395

    Maybe you're right, that's why I asked for mo...

    Maybe you're right, that's why I asked for mo betta info, it's kinda confusing the way it's written. I prefer

    RADB - xx
    RAWB- xx
    SADB- xx
    SAWB- xx
    LLT- Xx
    SLT- Xx
    Lpsig- xx
    Hpsig -...
  17. Thread: Txt

    by jtrammel
    Replies
    24
    Views
    395

    I see 99 with 6* SC

    I see 99 with 6* SC
  18. Thread: Txt

    by jtrammel
    Replies
    24
    Views
    395

    Return air wet bulb and pressure/sat temps (I...

    Return air wet bulb and pressure/sat temps (I could figure those out but too much thinking). Is the txv adjustable?
  19. Thread: Txt

    by jtrammel
    Replies
    24
    Views
    395

    Txt

    The Bryant txv thread is about the copeland scroll rust inhibitor. It presents itself with low suction pressure and high superheat (txv stuck more closed)

    Possibly the wrong valve. Is the bulb...
  20. Replies
    3
    Views
    170

    We sell one brand and have for many years. We can...

    We sell one brand and have for many years. We can and sometimes do under some circumstances offer a cheaper brand but 95% of our installs are with the same brand.
  21. Replies
    3
    Views
    145

    Those dampers work in reverse to what you're...

    Those dampers work in reverse to what you're wanting it to do. Also Combustion air has to be free from obstructions, if a damper were to fail closed it could cause a dangerous condition. There's...
  22. Thread: Manual J Help

    by jtrammel
    Replies
    12
    Views
    366

    This is York's...

    This is York's EAC technical paper. Of course I'm sure it's somewhat biased but it is a good EAC. I believe it's a rebranded Aprilaire model 5000. It's also the least restrictive on your duct system,
  23. Thread: Manual J Help

    by jtrammel
    Replies
    12
    Views
    366

    With that kind of heat load in a climate like...

    With that kind of heat load in a climate like Houston I think heat pumps would be a better and cheaper option. That way you'd have more to spend on the AC side. Any furnace is going to be way...
  24. Thread: Manual J Help

    by jtrammel
    Replies
    12
    Views
    366

    Clean effects drops of a lot as it loads up. I'm...

    Clean effects drops of a lot as it loads up. I'm not a fan of EACs, much prefer a 4-5" media filter.
  25. Replies
    10
    Views
    269

    Sorry not www.aquaproducts.us , it's...

    Sorry not www.aquaproducts.us , it's www.multiaqua.com I was thinking of.
  26. Replies
    12
    Views
    392

    I out offered you at 2.50, SOB declined my...

    I out offered you at 2.50, SOB declined my offer...

    I would like to have it but I have 4 leak detectors already so another one isn't at the top of my toy list.
  27. Replies
    10
    Views
    269

    Aqua products in SC?

    Aqua products in SC?
  28. Thread: 410

    by jtrammel
    Replies
    62
    Views
    1,387

    Because you're slugging the compressor with...

    Because you're slugging the compressor with liquid refrigerant. 0*SH.
  29. Sorry, here's the link...

    Sorry, here's the link https://www.netatmo.com/en-US/product
  30. It can do both, house leakage directly and duct...

    It can do both, house leakage directly and duct leakage by subtraction method. A blower door test and a duct blaster test would be more accurate though.

    Most attached garages leak into the living...
  31. Thread: quoting posts

    by jtrammel
    Replies
    19
    Views
    398

    No, you're gonna do it my way or we've got a...

    No, you're gonna do it my way or we've got a problem...jk
  32. Thread: 410

    by jtrammel
    Replies
    62
    Views
    1,387

    Your posts are hard to follow. All 'beer can...

    Your posts are hard to follow. All 'beer can cold' is is overcharging a unit to the point of 0 superheat (liquid refrigerant in the suction line), it doesn't matter if it's r22, r410a, r500, r600,...
  33. Replies
    10
    Views
    269

    Looks like a multicultural facility. I don't know...

    Looks like a multicultural facility. I don't know what all they make here or where it is. Looks like commercial vrf/vrv air handlers.
    http://youtu.be/XARE337DmeA
  34. Replies
    10
    Views
    269

    Daikan will be made in USA by Japanese workers.

    Daikan will be made in USA by Japanese workers.
  35. 1. 30 minutes or so with analogue guages, digital...

    1. 30 minutes or so with analogue guages, digital guages will show the leak much quicker.

    2. If it rises you either have a leak or moisture still in the system.

    3. You purge your hoses with...
  36. Replies
    3
    Views
    211

    Id make an elbow, radius or square with vanes.

    Id make an elbow, radius or square with vanes.
  37. Replies
    27
    Views
    776

    It's only as good as the inputs entered into the...

    It's only as good as the inputs entered into the formula. If you do it correctly and with a blower door test it's pretty accurate for 1% of the time.
  38. Thread: Txvalve

    by jtrammel
    Replies
    7
    Views
    214

    How old is the unit? 2013-2014 model? Copeland...

    How old is the unit? 2013-2014 model? Copeland compressor?
  39. Replies
    27
    Views
    776

    The only way to size an air conditioner so that...

    The only way to size an air conditioner so that it is correctly sized most of the time is to use variable capacity systems with zoning and major duct modifications and most folks can't afford all...
  40. Probably not, depends on your city and the AHJ....

    Probably not, depends on your city and the AHJ. Some require the contractor to submit a load calculation when they pull the permit but they don't check to see if it's right for the house.
  41. Not much, depends on your city. they should look...

    Not much, depends on your city. they should look at electrical, gas, plumbing, duct insulation, duct sealing, venting pertaining to the install to make sure it's all up to code.
  42. Replies
    27
    Views
    776

    Nobody understands it, or cares to, so everybody...

    Nobody understands it, or cares to, so everybody oversizes so they don't get calls when it's 98*F out and the AC won't get it below 74* in their house. If it's too humid we sell you a whole house...
  43. Replies
    27
    Views
    776

    Yes and even the ones that are correctly sized...

    Yes and even the ones that are correctly sized with manual J are oversized 99% of the season.
  44. Thread: 410

    by jtrammel
    Replies
    62
    Views
    1,387

    The higher pressure ain't got jack to do with how...

    The higher pressure ain't got jack to do with how a heat pump works, 110*F condensing sat temp is 110*F no matter what refrigerant pressure it is (ie R22 226psig = 110*F, r410a 365psig= 110*F)....
  45. Replies
    12
    Views
    392

    Lolz

    Lolz
  46. Replies
    23
    Views
    863

    It's in the IMC, if in unconditioned space it...

    It's in the IMC, if in unconditioned space it should be double wall all the way to the furnace.
  47. No unless you find a Craigslist hack to hack...

    No unless you find a Craigslist hack to hack something up, it'll likely cost you more in the long run.

    Prices vary drastically from state to state, city to city, and company to company so it's...
  48. Thread: 410

    by jtrammel
    Replies
    62
    Views
    1,387

    You can charge 410 to beer can cold just like any...

    You can charge 410 to beer can cold just like any refrigerant.
  49. 1. Somewhat True as the type of refrigerant has...

    1. Somewhat True as the type of refrigerant has changed and is likely not compatible with your old indoor unit.

    2. No, big box stores just use a local contractor and tack on some money so they...
  50. ACCA manual D.

    ACCA manual D.
Results 1 to 50 of 863
Page 1 of 18 1 2 3 4