    By the way, I made a mistake on the model # it's...

    By the way, I made a mistake on the model # it's 38ARQ008-601
  2. Replies
    13
    Views
    2,501

    I spoke to Carrier about the length which is ok....

    I spoke to Carrier about the length which is ok. I had to shorten the length from the original unit. The LLSV is facing toward the outdoor unit.
  3. Replies
    13
    Views
    2,501

    It's working right now because it's not as cold...

    It's working right now because it's not as cold but it was out last week. It's a new install from the summer. All specs were followed. The lineset is right at 95 feet with a LLS installed. I was...
  4. Replies
    13
    Views
    2,501

    Compressor Lockout (CLO) shutting unit down

    Carrier 38ARQOO8 is shutting down in heat mode on (CLO) because it's located in a parking garage with very little heat for the outdoor unit to absorb. The manual says it's the freezestat. The unit is...
  5. Replies
    33
    Views
    1,638

    I really think that Kwame should be removed from...

    I really think that Kwame should be removed from office but is the next guy or girl gonna be any better? Most government officials are corrupt or should I say not completely honest. Look at the...
  6. Replies
    26
    Views
    8,546

    Too many. as well as dirty coils. I am thinking...

    Too many. as well as dirty coils. I am thinking of installing the 16 SEER Carrier in my home together with an existing propane furnace. My propane bill is outragous right now. It averages 700 - 800 a...
  7. Replies
    10
    Views
    1,483

    ROLL TIDE !!!! Sorry I had to do that.

    ROLL TIDE !!!! Sorry I had to do that.
  8. Replies
    4
    Views
    851

    Sorry it's been a while since I've been here but...

    Sorry it's been a while since I've been here but yes I found a trap in the suction line preventing the oil from coming back so I cut it out but now I need a new compressor anyway.
  9. Replies
    5
    Views
    499

    I've seen it used with a fan coil but not quite...

    I've seen it used with a fan coil but not quite sure what they did for cooling.
  10. Replies
    52
    Views
    3,244

    The best advise that I can give you is to look in...

    The best advise that I can give you is to look in the Modern Refrigeration text book. It has pictures of the process. Flash gas takes place in the beginning of the metering process and if the...
  11. Replies
    303
    Views
    27,108

    If your indoor coil is cold in the middle then it...

    If your indoor coil is cold in the middle then it sounds like you have a blockage. If the line temp is 135 the air temp maybe at least 100 - 115 degrees. One other thing you need to look at is...
  12. Replies
    21
    Views
    1,148

    Try the Nike boot. It is very comfortable. It's...

    Try the Nike boot. It is very comfortable. It's fits like a sneaker and water resistant. I work on rooftops with those big limestone rocks and these boots are the only thing I wear. They cost between...
  13. Replies
    4
    Views
    851

    I found out what was wrong. The unit had over 100...

    I found out what was wrong. The unit had over 100 feet of line set which is too much liquid for the semihermetic compressor. I had to shorten the run of pipe but in the mean time the compressor has...
  14. Replies
    4
    Views
    851

    Carrier 38aqs008 Problems

    What's up guys? I have a carrier 8 ton heat pump unit that is located in a parking garage that is 49" from the drop ceiling. The customer does not want to relocate the unit but it recirculating the...
  15. Replies
    9
    Views
    788

    DO YOU HAVE A CONDENSATE PUMP? CHECK AND SEE IF...

    DO YOU HAVE A CONDENSATE PUMP? CHECK AND SEE IF IT'S FULL AND OUT ON THE SAFETY SWITCH. IF NOT, VERIFY THAT YOU HAVE 24 VOLTS TO THE OD CONTACTOR.
  16. Replies
    0
    Views
    519

    ARE THERE ANY GREAT TECHS LOCATED IN THE DC METRO...

    ARE THERE ANY GREAT TECHS LOCATED IN THE DC METRO AREA (SOUTHERN MARYLAND, MONTGOMERY COUNTY, ETC.) LOOKING FOR A GREAT PLACE TO WORK AND SHOW OFF THERE PROFESSION. PAYS GREAT! FUN DRUG FREE WORK...
Results 1 to 16 of 16
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event