  1. Replies
    2
    Views
    377

    Carrier 25 Hna6 heat pump

    Fault code 72, Bristol compressor overheated, anyone having trouble with this compressor, I heard from rep that Bristol is having problems with 2 speed compressor
  2. Replies
    11
    Views
    2,094

    ran in high fire 10 minutes, been installed since...

    ran in high fire 10 minutes, been installed since 2008 and trouble free
  3. Replies
    11
    Views
    2,094

    carrier fault code 33 on 58mvc

    have fault code 33 on carrier mvc, works fine in high fire, ran fine for 10 minutes each in low and medium fire through the check out in infinity controller. brand new infinity air purifier filter...
  4. Replies
    7
    Views
    1,657

    Hot or cold water for humidifier

    been in this business for 20 years and have been hearing from other contractors that they hook up humidifiers on hot water line. i have always hooked up to cold water, any thoughts from others would...
  5. Replies
    0
    Views
    651

    59tp5 carrier furnace

    new furnace is out, just wondering if anyone has installed this model yet and what are the thoughts good or bad.
  6. Replies
    4
    Views
    763

    if system has a txv, chances are thats your...

    if system has a txv, chances are thats your problem. had the same situation last week on a ac system. suction was 40, head was 225. pulled apart and evap coil was half frosted up, replaced txv and...
  7. Replies
    6
    Views
    1,618

    really good chance the evap coil is leaking, its...

    really good chance the evap coil is leaking, its called formicary corrosion, replace with a tin plated coil
  8. Replies
    14
    Views
    752

    going tomorrow to spray water on condenser coil...

    going tomorrow to spray water on condenser coil while unit runs and see what happens. if continues to run i am going to hook up a sprinkler on the coil for 24 hrs and see what happens
  9. Replies
    14
    Views
    752

    all worked fine with old unit till 2 days ago...

    all worked fine with old unit till 2 days ago when compressor crapped out. only replaced condenser because air handler is in attic and its 130 in the attic
  10. Replies
    14
    Views
    752

    not a home owner, it is an r-22 unit, charge was...

    not a home owner, it is an r-22 unit, charge was weighed in according to factory recomendation plus 12 ounces for addition 20 feet of lineset
  11. Replies
    14
    Views
    752

    compressor overload on new install

    installed a new dry ship goodman today and weighed in charge. operating pressures were 110 suction and 350 head. needless to say the compressor overloaded after 5 minutes of running. outdoor temp was...
  12. Replies
    10
    Views
    816

    most of my leakers are carrier just a couple yorks

    most of my leakers are carrier just a couple yorks
  13. Replies
    10
    Views
    816

    its ridiculous replacing coils that are 1 2 and...

    its ridiculous replacing coils that are 1 2 and 3years old because of this, seems every day i have at least 1 call of a no ac because of this damn problem. you sell new systems to update and then...
  14. Replies
    10
    Views
    816

    formicary corrossion

    is it just me or is formicary corrossion a legit problem or is it really just cheaper copper causing tons of evap coil leaks
  15. Replies
    5
    Views
    703

    heat pump question

    working on a heat pump today and unit is stuck in heat mode. i am not real keen on heat pump service. i unhooked the wire to the o terminal in heat mode and the unit did not shift to the cool side,...
  16. Thread: goodman ssx 14

    by workhc
    Replies
    8
    Views
    1,787

    not worried about seer rating, just wondering if...

    not worried about seer rating, just wondering if the txv is required. i know york requires a txv with the 14.5 seer unit. i am used to carrier, all of their coils have factory installed txv
  17. Thread: goodman ssx 14

    by workhc
    Replies
    8
    Views
    1,787

    what are your thoughts on this model

    what are your thoughts on this model
  18. Thread: goodman ssx 14

    by workhc
    Replies
    8
    Views
    1,787

    goodman ssx 14

    does this model require the use of a txv or can you use piston
  19. Replies
    15
    Views
    1,181

    the only reason the rollout switch in burner box...

    the only reason the rollout switch in burner box is tripping is because the secondary heat exchanger is plugged up. as a carrier dealer i found a bad one today and have replaced secondarys on this...
  20. Replies
    2
    Views
    449

    carrier failed secondary's

    is it just me or are there a ton of carrier secondary failures with the 40" furnaces lp gas and natural
  21. Replies
    69
    Views
    9,178

    because we have been a carrier dealer for 40...

    because we have been a carrier dealer for 40 years, they make good equipment but sometimes people are only after price, and we all know price should not be the deciding factor but we all gotta put...
  22. Replies
    69
    Views
    9,178

    good to know tat about the mods and the bigger...

    good to know tat about the mods and the bigger coils, i sell york as a 2nd line but mostly the tm9x models or on ocassion the tg9, i really like the tm9x model its cost effecient and works good for...
  23. Replies
    69
    Views
    9,178

    14.5 seer with a bigger coil and txv with...

    14.5 seer with a bigger coil and txv with variable speed or x 13 motor will get you 16 seer and 13 eer
  24. Replies
    69
    Views
    9,178

    anybody thats not in this field will not know the...

    anybody thats not in this field will not know the differewnce, they will not know if its in 2nd stage or if its slowly modulating, hell i install carrier and i can hardly tell the difference between...
  25. Replies
    69
    Views
    9,178

    homeowner will not recognize the difference...

    homeowner will not recognize the difference between modulating and 3 stage
  26. Replies
    69
    Views
    9,178

    the carrier can operate on a standard 2 stage stat

    the carrier can operate on a standard 2 stage stat
  27. Replies
    69
    Views
    9,178

    get a quote on a carrier 58mvc model. it has 3...

    get a quote on a carrier 58mvc model. it has 3 stages of heat, variable speed inducermotor and variable speed blower motor. couple it up with a heat pump and the infinity controller and you have the...
  28. Thread: goodman gmh

    by workhc
    Replies
    2
    Views
    471

    goodman gmh

    someone give me thoughts good or bad about this furnace
  29. Thread: odd refrigerant

    by workhc
    Replies
    1
    Views
    577

    odd refrigerant

    came across an old carrier residential unit today and the plate on the unit said to charge with refrigerant c-7. this unit is 50 years old if its a day and in my 22 years in this business i have...
  30. Replies
    14
    Views
    3,903

    i am in the business, i mostly do residential and...

    i am in the business, i mostly do residential and lite commercial. i know the drain line is open because the drain line runs down the outside of the wall inside the building, i disconnected the hose...
  31. Replies
    14
    Views
    3,903

    comfort air, installed 2 years ago with no...

    comfort air, installed 2 years ago with no problems till now
  32. Replies
    14
    Views
    3,903

    mini split water leak

    i am not a do it yourselfer for starters, i have a mini split that leaks water down the front of the coil and leaks out the front of the unit, i checked the drain line and it is open, coil is not...
  33. Replies
    16
    Views
    3,811

    in todays market with the tax credits, a lot of...

    in todays market with the tax credits, a lot of 2.5 ton condensers need to be matched with 4 ton coils to reach 16 seer. i have done it a number of times with no trouble.
  34. Replies
    26
    Views
    2,215

    take a look at carriers infinity infinity system...

    take a look at carriers infinity infinity system with the duel fuel heat pump, very nice system with the infinity controller.
  35. Thread: carrier 24abc6

    by workhc
    Replies
    7
    Views
    5,615

    speaking of changing, they brought out the 95%...

    speaking of changing, they brought out the 95% single stage furnace, as you probably already know,and its an icp product identicle to the tempstar and heil. very nice furnace, runs quiet and easy to...
  36. Thread: carrier 24abc6

    by workhc
    Replies
    7
    Views
    5,615

    its good you are so informative to help a lot of...

    its good you are so informative to help a lot of people. i have been in this business over 20 years (carrier dealer) and just found out about the 24abc, i had no idea they were eliminating the abb4...
  37. Thread: carrier 24abc6

    by workhc
    Replies
    7
    Views
    5,615

    ryan, ive seen you on here before, you seem...

    ryan, ive seen you on here before, you seem pretty informed on a lolt of different things, are you a salesman, installer, or serviceman.
  38. Thread: carrier 24abc6

    by workhc
    Replies
    7
    Views
    5,615

    carrier 24abc6

    does anyone know if this is a single speed ac or a 2 speed acc, there is nothing on the carrier website about this model
  39. in my 20 plus years i never run low voltage wire...

    in my 20 plus years i never run low voltage wire in any type of conduit, i have always just taped it to the lineset, i have never had an issue with uv or animals or anything.
  40. Replies
    6
    Views
    943

    cnpvp for both furnaces

    cnpvp for both furnaces
  41. Thread: Bryant vs. YORK

    by workhc
    Replies
    5
    Views
    885

    as a carrier dealer (same as bryant) it is good...

    as a carrier dealer (same as bryant) it is good equipment and you wont go wrong. i would look into the evolution system, nobody has anything close to this. however i do sell a small amount of york...
  42. Replies
    42
    Views
    4,903

    80% afue ends in 2013

    was at a dealer meeting and they said 2013 or around there minimum efficiency is going to 90%. any one heard this, what are we to do about attic installs, im not putting condensing furnaces in...
  43. is that furnace condensing, if so may have...

    is that furnace condensing, if so may have plugged up condensate trap, i had something similar this winter and it ended up being the gas valve. one other thing to check is make sure the furnace has a...
  44. Replies
    6
    Views
    943

    do not use n coil on carrier furnace model hdx....

    do not use n coil on carrier furnace model hdx. that furnace is icp product and states right on top of furnace not to use it. i personnally hate the n coil because of the pan, the only good thing...
  45. Replies
    6
    Views
    943

    i believe the capvp is discontinued, going to...

    i believe the capvp is discontinued, going to cnpvp (n coil). the capvu (uncased a coil) is still available but it is actually a little wider than the plenum opening above the furnace and makes it...
  46. Replies
    63
    Views
    4,218

    basically because of money. my area for the most...

    basically because of money. my area for the most part is looking at initial cost. most of my competition is goodman, i personally love the carrier infinity systems, but can only sell it to the right...
  47. Replies
    13
    Views
    1,301

    i was at a carrier dealer meeting on wednesday...

    i was at a carrier dealer meeting on wednesday and a rep from carrier said the are redesigning air handlers tlo make them smaller, he did not give a time frame but should be available next year
  48. Replies
    63
    Views
    4,218

    do sell carrier high end that is communicating,...

    do sell carrier high end that is communicating, been to the classes and all that good stuff, im not interested in doing the communicating stuff for goodman, cause i really dont anticipate selling too...
  49. Replies
    63
    Views
    4,218

    good to know thank you much never had to do that...

    good to know thank you much never had to do that with carrier equipment
  50. Replies
    63
    Views
    4,218

    why do i need to jumper y1 to y2 it is a single...

    why do i need to jumper y1 to y2 it is a single stage 10 year old armstrong ac