    Help on Birch egg cooler

    Need to know average low side pressure on a R-22 egg cooler on a chicken farm. room temp needs to run at 65 .
  2. Replies
    2
    Views
    1,001

    Help on Birch egg cooler.

    My friend works on birch egg coolers on chicken farms. But he is out of town He installed one yesterday that he put a compressor in. He called me to see if I would check on it for him The egg owner...
  3. Replies
    2
    Views
    486

    Heip on Birch Egg cooler.

    My friend is out of town , He works on egg coolers on chicken farms he calls me to go see about one he installed yesterday The owner called and saidT it froze up last night THE installer said the...
  4. Replies
    2
    Views
    420

    cps micron gauge

    Is the cps vg 200 a good buy?
  5. Thread: super pro

    by frostyac
    Replies
    14
    Views
    1,577

    www. hvacsuperpro.com

    www. hvacsuperpro.com
  6. Thread: super pro

    by frostyac
    Replies
    14
    Views
    1,577

    A bondiing joint compound to replace brazing ...

    A bondiing joint compound to replace brazing copper tubing. Some thing new.
  7. Thread: super pro

    by frostyac
    Replies
    14
    Views
    1,577

    super pro

    What is your coments on this new super pro ?
  8. Thread: armstrong txv

    by frostyac
    Replies
    11
    Views
    1,810

    OUT DOOR EXPANSION VALVE # 78L19

    OUT DOOR EXPANSION VALVE # 78L19
  9. Thread: armstrong txv

    by frostyac
    Replies
    11
    Views
    1,810

    Just got home from installing a 2 ton txv on a...

    Just got home from installing a 2 ton txv on a armstrong cond. unit got it at cc dickson
    no prob. Do you need a number ??
  10. Thread: s.p. issue

    by frostyac
    Replies
    1
    Views
    439

    s.p. issue

    2 1/2 TON HP. [ PACK ] out side on slab. supply 14 "pipe run up out side wall 8 ft. elbowed in attic run 15 ft. to dist. box 20 x20. 8 run outs 4 - 8 " flex runs 15 ft. 4- 6 " runs 8 to 12 ft. TL= ...
  11. Replies
    106
    Views
    6,654

    Ac Man

    When you walk into a drug store in 1950 and wonder how it makes the air cold , and now 58 years later iam still wondering. ha ha
  12. Replies
    4
    Views
    490

    cond fan runs backwards

    I have a 2 ton goodman, Cond fans starts runs for a while , then starts running backwards . [ changed cap still run backwards ] seen this a few times with lighting strikes , seen no bad weather in...
  13. Replies
    6
    Views
    846

    hot line

    Check cond. fan, and clean cond. hp to high
  14. Thread: Member

    by frostyac
    Replies
    3
    Views
    429

    Member

    Capacitor with no info. How do know what MFD to use?
  15. Replies
    10
    Views
    810

    I had a contactor awhile back had 24 v on coil...

    I had a contactor awhile back had 24 v on coil but it would not go in.had extra wire on t stat change wire work fine.
  16. Thread: Goodman HP ?

    by frostyac
    Replies
    3
    Views
    731

    Yes it is. 45 degree out side it should do the...

    Yes it is. 45 degree out side it should do the job with out heat strips, got me in the wondering mode. Home owner says when it drops to around 40 F out side it will not heat the house with out...
  17. Thread: Goodman HP ?

    by frostyac
    Replies
    3
    Views
    731

    Working on a 1 1/2 ton Goodman heat pump.My prob....

    Working on a 1 1/2 ton Goodman heat pump.My prob. is can not get but 120 degree on vapor line to inside coil .I jumperd the rev. valve blocked off cond fan got head pressure up to 300 lb. SP = 70 LB....
  18. Replies
    4
    Views
    1,603

    I used a new sensor , the old sensor was a bulb...

    I used a new sensor , the old sensor was a bulb sensor Ranco E-15 The new sensor is a NTC type.I moved sensor to a well where the old bulb was in.I will go back later to see if this worked.
    ...
  19. Replies
    4
    Views
    1,603

    It will go into defrost when you jumpe the pins,...

    It will go into defrost when you jumpe the pins, but it will not on its own.The old sensor was in a well,do i need to put it back in the well on the coil? May be bad board.
  20. Replies
    4
    Views
    1,603

    I have replaced a Ranco E-15 defrost control to a...

    I have replaced a Ranco E-15 defrost control to a ICM315C CONTROL.I can not get it to defrost. I did not insulate the sensor, this is a thermistor sensor, do i need to?
  21. Replies
    2
    Views
    861

    I replaced a defrost board on a old heat pump 20...

    I replaced a defrost board on a old heat pump 20 yr. old donot know the brand name.It had a ranco E15 DEFROST control.Can not get it to manualy defrost.I jumped out sensor pins and shorted defrost...
  22. Replies
    19
    Views
    1,791

    The burners may need cleaning.

    The burners may need cleaning.
  23. Replies
    7
    Views
    1,416

    Does that mean yepper for yes ?

    Does that mean yepper for yes ?
  24. Replies
    7
    Views
    1,416

    Is that greek for dont no ?

    Is that greek for dont no ?
  25. Replies
    7
    Views
    1,416

    What is the tonage on this rheem air handler ? #...

    What is the tonage on this rheem air handler ? # RBHA - 24 -J20SFAA. 5 TON ?