  1. Replies
    14
    Views
    389

    Yeah, I get that...but a "adjustable" tev that...

    Yeah, I get that...but a "adjustable" tev that requires the removal of the suction line seems a bit...........troublesome. all those non combustibles and all...
  2. Which H-10 is the latest and the hot tip?

    thanks
  3. Replies
    14
    Views
    389

    then they should put in a cap tube..

    then they should put in a cap tube..
  4. Replies
    14
    Views
    389

    commodity managers need to set the superheat on...

    commodity managers need to set the superheat on these then..I called sporland this morning and asked for a REAL replacement valve number. Hope what I get is what I need...
  5. Replies
    14
    Views
    389

    OMG you won't believe where some of the...

    OMG you won't believe where some of the condensing units are that I work on..
  6. Replies
    14
    Views
    389

    to remove the suction line is a miserable...

    to remove the suction line is a miserable job..theres maybe 8" of room between the evaporator and the inside wall...I wish I could talk to the designer of the box and txv...
  7. Replies
    14
    Views
    389

    sporlands NI txv..

    Can someone tell me why they came up with a valve that requires you pull the suction line off of to adjust the super heat??

    and what real valve Ill need to replace the many NIV-1/2's that is...
  8. Replies
    7
    Views
    447

    Good thought ^^

    Good thought ^^
  9. Replies
    7
    Views
    447

    I read that the H10B isn't the hot tip anymore..I...

    I read that the H10B isn't the hot tip anymore..I think Ill just buy a G....

    thanks:cheers:
  10. Replies
    7
    Views
    447

    H-10B leak detector question

    Im changing the case to a more sturdy one, the original is ate up.

    I noticed a large "screw" at the bottom of the detector and the original case
    has a hole for what maybe an adjustment of this...
  11. Replies
    17
    Views
    685

    Ok, heres what I did..captaincompressor got me...

    Ok, heres what I did..captaincompressor got me thinking I had a superheat gauge, and I did..
    hooked it up and I didn't believe my lying eyes...so i hooked up my digital thermometer to the
    inlet and...
  12. Replies
    17
    Views
    685

    Im looking for 20+* of compressor SH so I have a...

    Im looking for 20+* of compressor SH so I have a ways to go it seems.

    thanks all.
  13. Replies
    17
    Views
    685

    thanks shellkamp.

    thanks shellkamp.
  14. Replies
    17
    Views
    685

    This system was low on refrigerant and the box...

    This system was low on refrigerant and the box temp was +22*..I added freon per sight glass and head psi. (headmaster is on system)

    box came down to +14.9* and stopped dropping....I took the above...
  15. Replies
    17
    Views
    685

    no its not frozen at all, and fans are in order...

    no its not frozen at all, and fans are in order
    ..where i get lost in the SH is when the temps and psi's are in the negative..
  16. Replies
    17
    Views
    685

    link needed to calculate superheat..

    Everytime i go to check SH and all is in the negative numbers, I want to kill myself.

    404a system, 4 door reaching freezer...

    box temp..+15*, need 0 or less
    ambient...100*
    head....300psi...
  17. Thread: R12

    by primmers
    Replies
    21
    Views
    1,133

    the last bottle of r12 i bought was $300.

    the last bottle of r12 i bought was $300.
  18. Thread: R12

    by primmers
    Replies
    21
    Views
    1,133

    ^^out in the middle of nowhere...its less than...

    ^^out in the middle of nowhere...its less than r22 that for sure.
  19. Replies
    12
    Views
    623

    thanks guys..

    thanks guys..
  20. Thread: R12

    by primmers
    Replies
    21
    Views
    1,133

    I have plenty of customers that still can use...

    I have plenty of customers that still can use it...
  21. Replies
    12
    Views
    623

    this one is, has two slots in it for some kind of...

    this one is, has two slots in it for some kind of spanner wrench......
  22. Replies
    12
    Views
    623

    service valve jam nut tool..

    back in the old days you could use a small crescent wrench to tighten the
    jam nut to keep freon from leaking past the stem...seems the manufacture of this valve went away from the flats:gah:
    and...
  23. Replies
    4
    Views
    419

    Thanks baub...this is exactly what i need..

    Thanks baub...this is exactly what i need..
  24. Replies
    4
    Views
    419

    never mind, i found one ...whats weird is the...

    never mind, i found one ...whats weird is the number my vendor gave me is a tecumseh number I've never seen...K- something.....

    thanks anyway.
    ...
  25. Replies
    4
    Views
    419

    Tecumseh relay list..

    I have the Tecumseh hermetic compressor service handbook, and wouldn't you know it, it doesn't cover
    what relay goes into what compressor like the copeland book does,,,,,,,,


    and my vendor gave...