  1. are you sure your meter was reading uf not nf. I...

    are you sure your meter was reading uf not nf. I have had my meter read 5 nf on a 5 uf capacitor. nano farads are smaller than micro farads hence the cap is done when your meter reads nano farads.
    ...
  2. Customers or Contractors may want to read Will's...

    Customers or Contractors may want to read Will's Terms and Conditions Web Page..

    They cannot be held liable for any information or miss information given to customers.

    They hold no liability...
  3. Remember we all know that the majority of duct...

    Remember we all know that the majority of duct systems are sized right!! NOT

    Most systems are sized right!! NOT

    Customer know what size they want!! NOT

    An onsite review is not necessary!!...
  4. I guess you are ignoring the Fact on the post by...

    I guess you are ignoring the Fact on the post by Brent on Internet Sales exclusion from Mitsubishi dated May of 2014.

    Per Mitsu:

    Company Statement Regarding Internet Sales of Mr. Slim® Products...
  5. Will, I see absolutely no educating or...

    Will,

    I see absolutely no educating or informing of your target customers on your ebay pages from samedaysupply inc. about the need for proper sizing or the need for proper installation by a...
  6. Look at that you even do sell on ebay. Welcome...

    Look at that you even do sell on ebay. Welcome samedaysupply inc. for all your ebay needs.. Do you do craigslist also?

    Never did answer the question of:

    Are you teaching these customers how to...
  7. Many distributers of hvac products charge a...

    Many distributers of hvac products charge a warranty handling fee if not purchased thru them. Your customers will have to know that there may be a charge for warranty parts. And some distributers...
  8. Replies
    4
    Views
    272

    The guardian REME is a ROS system which stands...

    The guardian REME is a ROS system which stands for Reactive Oxygen Species output.. They call the out put peroxides. Be careful using or recommending any system that outputs ROS or peroxides as they...
  9. Hello, From the fieldpiece slr8 user manual:...

    Hello,

    From the fieldpiece slr8 user manual: If no sensor is installed or the installed sensor is
    broken when the unit is turned on an alarm will
    sound and the unit will turn off.

    Sounds like...
  10. time to ask you boss for thermostat wiring 101...

    time to ask you boss for thermostat wiring 101 training if your in the business or pick up the phone if you are a diy...

    Goodluck
    J
  11. Replies
    20
    Views
    1,414

    cooper atkins k type calibration prover #9319,...

    cooper atkins k type calibration prover #9319, note that this does not verify the accuracy of the k-type probe only that the meter reads correctly to a standard at 32/100/160.

    Goodluck
    J
  12. Replies
    11
    Views
    860

    get a cooper 9315 thermistor prover to test that...

    get a cooper 9315 thermistor prover to test that calibration of your meter yourself..
  13. Replies
    8
    Views
    391

    You said that the units have a trap at the units...

    You said that the units have a trap at the units then also the main drain that the units tie into have a trap outside also.. Did you verify that there is a vent in the line after each trap that is at...
  14. That thermostat is not a thermostat that can be...

    That thermostat is not a thermostat that can be hooked to a router that I know of.. Based on the serial number the thermostat is from the 47th week of 2007.. Back then I don't believe carrier or...
  15. Replies
    3
    Views
    674

    Most detectors I have used picked up R-22 more...

    Most detectors I have used picked up R-22 more readily than r-410a, so I always use r-22 as my tracer gas with nitrogen. Both refrigerants can be used as a tracer gas but I have had better luck with...
  16. Replies
    12
    Views
    671

    Straight from Ducane warranty paper: This 5-Year...

    Straight from Ducane warranty paper: This 5-Year Llimited Extended Parts Warranty does not apply to, and no warranty is offered by Allied Air, on any unit ordered over the internet. Proof of...
  17. Replies
    12
    Views
    671

    Why would you buy the unit yourself, you did read...

    Why would you buy the unit yourself, you did read the warranty on said unit. No warranty is offered by any manufacturer that is purchased outside the normal supply chain.. i.e. mail order or internet...
  18. There is no way a seasoned or as you put it a...

    There is no way a seasoned or as you put it a journeyman hvac specialist can tell how tight your house is without a blower door test done to CFM50 standards..

    I have seen foamed insulated houses...
  19. The duct slide calculator is just that, it is not...

    The duct slide calculator is just that, it is not meant to size ductwork until a friction rate is known to use on the slide calculator.

    To find the proper friction rate, one needs to first know...
  20. Replies
    14
    Views
    903

    To utilize your currect airhandler, your indoor...

    To utilize your currect airhandler, your indoor txv will need to be replaced and the coil and lineset flushed of any oil.. Also a contractor will need to match an appropriate heat pump condenser..
    ...
  21. Replies
    15
    Views
    1,057

    Call your carrier distributor,, they will advise...

    Call your carrier distributor,, they will advise you of the proper checks to verify what is wrong.. I know what is wrong but cannot discuss in the open forums..

    Goodluck
    J
  22. Replies
    77
    Views
    5,277

    looks like the standard sub-par design from...

    looks like the standard sub-par design from someone that doesn't understand Manual D.. No mention of TEL and mostly 6 inch runouts.. funny..

    You get what you pay for... A diy install will get a...
  23. Replies
    176
    Views
    19,919

    I got a 550 paper weight that has been sitting in...

    I got a 550 paper weight that has been sitting in my garage for a little while now..
    Let see the hook broke then one of the two pipe clamps quit reading temp, then the meter quit reading the temp...
  24. I deal with carrier on a daily basis.... The...

    I deal with carrier on a daily basis.... The 24ANA7 was discontinued..Period.. It was a infinity cabinet with the two stage recip compressor..

    When the 24ANA7 was discontinued they developed a...
  25. Mike, The unit that used the bristol 2-stage...

    Mike,

    The unit that used the bristol 2-stage reciprocating compressor was the 24ANA7 but the new model is a 24ANA1 that uses the scroll unloading compressor... The new 24APA7 uses the same scroll...
Results 1 to 25 of 500