Search:

Type: Posts; User: stat

Page 1 of 4 1 2 3 4

Search: Search took 0.00 seconds.

  1. Replies
    7
    Views
    431

    My reply to a similar query "The day I can...

    My reply to a similar query

    "The day I can see the future is the day I stop carrying tools for a living."
  2. Replies
    25
    Views
    808

    x2 The AC compressor in the store I service has...

    x2
    The AC compressor in the store I service has been out for two years..
  3. Kwik Trip?

    Kwik Trip?
  4. Replies
    22
    Views
    1,062

    There are three roof heights and two wheel bases....

    There are three roof heights and two wheel bases. The picture is of the standard height. I am interested in the medium height long wheel base which I believe is approximately 5'10" inside. Three...
  5. Replies
    22
    Views
    1,062

    Yes. I think it is what I want next. I want to...

    Yes. I think it is what I want next. I want to see one in person.
  6. Replies
    6
    Views
    338

    5%, 45% and staybrite

    5%, 45% and staybrite
  7. Replies
    71
    Views
    1,389

    So now you have a cap tube system with a receiver...

    So now you have a cap tube system with a receiver ?
  8. Replies
    71
    Views
    1,389

    Isn't that second condenser completely full of...

    Isn't that second condenser completely full of liquid?
  9. I just bought MB2 bag to use for trouble...

    I just bought MB2 bag to use for trouble shooting. I was wishing it was a little bigger.
  10. Replies
    29
    Views
    1,080

    In my jurisdiction the fire inspector will shut...

    In my jurisdiction the fire inspector will shut down a kitchen if the exhaust fans are found not to be working. The exhaust fans need to be running in case of fire. He will also require any cooking...
  11. Replies
    71
    Views
    1,389

    Condensing unit R404 TXV/receiver ETC ...

    Condensing unit
    R404
    TXV/receiver
    ETC

    Everybody wins
  12. Replies
    11
    Views
    572

    Suction line icing back on a freezer means...

    Suction line icing back on a freezer means nothing. On most of my systems ice on the suction line means everything is working properly. Make sure the evap is ice free, the box is close to temp and...
  13. Thread: Age old debate

    by stat
    Replies
    22
    Views
    1,103

    Been using Stay Brite for 25 years, including R22...

    Been using Stay Brite for 25 years, including R22 medium temp discharge lines. Never had an issue.
  14. Replies
    71
    Views
    3,485

    Around here the service dept of the restaurant...

    Around here the service dept of the restaurant supply company tells the customer it can't be fixed and the unit needs to be replaced.

    Actually, they do that to all equipment they look at. Keeps...
  15. Replies
    32
    Views
    1,293

    Just like the CPR, the pressure limiting TXV...

    Just like the CPR, the pressure limiting TXV prevents the compressor from excessive suction pressure, not flooding. Using the pressure limiting TXV saves you the cost of buying a CPR valve. This...
  16. Replies
    32
    Views
    1,293

    Never installed a condensing unit with an...

    Never installed a condensing unit with an accumulator in 25yrs, including the two low temps I put in last week. I have however seen systems with accumulators still flood compressors.

    Use a...
  17. Replies
    71
    Views
    3,485

    Anything made by Cold-Tech

    Anything made by Cold-Tech
  18. I trap the cooler at the coil, trap the freezer...

    I trap the cooler at the coil, trap the freezer line inside the cooler then tee into the common line
  19. Replies
    8
    Views
    16,691

    Make sure the cut in pressure saturated suction...

    Make sure the cut in pressure saturated suction temperature is below the coldest ambient temperature. Around here on R22 I use 8lbs CI and 2lbs CO. This will keep it running when it is -20F.
  20. Replies
    22
    Views
    1,440

    Screen roller tool

    Screen roller tool
  21. Replies
    23
    Views
    1,401

    I have worked out of a pick up for nearly 25...

    I have worked out of a pick up for nearly 25 years. Most of my trucks have had high side boxes and a gang box behind the cab. I did have a Reading cap once similar to the A.R.E and I liked that...
  22. Thread: Veto tool bags

    by stat
    Replies
    75
    Views
    7,865

    I Have been using a Tech LC for about a year and...

    I Have been using a Tech LC for about a year and it is hands down the best bag I have used. I now also have a Pro Pac. It is a lot easier to haul up a ladder than a shoulder bag, but I don't like...
  23. Replies
    17
    Views
    1,131

    I use 409

    I use 409
  24. Replies
    10
    Views
    601

    I have one account with the furnace next to the...

    I have one account with the furnace next to the dryer and no outdoor CA. Flame sensor needs to be cleaned at least once a year, sometimes twice. I have suggested a second pipe as a solution but...
  25. Replies
    7
    Views
    440

    Refrigerant will migrate to the coldest part of...

    Refrigerant will migrate to the coldest part of the system. If it is colder out side than inside, that's where the refrigerant will be. Makes no difference if the furnace is running. On a -10F day...