Search: Search took 0.00 seconds.

  1. Replies
    1
    Views
    256

    No one? I tried to check into hdb file...

    No one?

    I tried to check into hdb file (history database) but I think it's a proprietay file
  2. Replies
    1
    Views
    256

    [AX/N4] Custom values chart

    Hi Guys,

    I want to create a chart with custom value, for example create bargraph with monthly unified degree day since 5 years.

    I try to create a history and modify it but I can just change...
  3. Replies
    5
    Views
    310

    What s your TCOM driver version on Jace and on FG?

    What s your TCOM driver version on Jace and on FG?
  4. Replies
    5
    Views
    310

    Not in same network?

    Not in same network?
  5. Replies
    55
    Views
    4,067

    Spyder is slow (download) not enough module...

    Spyder is slow (download) not enough module etc... but there isn't others open programmable controllers. He isn't the best but he is almost alone... the big problem with spyder is behind the screen,...
  6. Replies
    55
    Views
    4,067

    Be careful Godwin's law is near ! Anyway...

    Be careful Godwin's law is near !

    Anyway BACnet/IP is better than MSTP because it s most faster. If you have a crap network with many packet collision it will be ''transparent'' through IP.
    ...
  7. And Distech is a good stuff but lock. Just...

    And Distech is a good stuff but lock.

    Just EasyIO provide powerful, innovative and open products. No dealer, no license.
    The only problems is support (Singapor, Europe) and FG series is young...
  8. WEBs is open, you can use it through any brand...

    WEBs is open, you can use it through any brand workbench.

    EasyIO are working on a controller through N4 but not before 2017.
  9. Replies
    18
    Views
    1,973

    http://gofile.me/32wEs/gICnKFEek

    http://gofile.me/32wEs/gICnKFEek
  10. Replies
    18
    Views
    1,973

    Yes it's existing VykonPro N4, I never check if...

    Yes it's existing VykonPro N4, I never check if there is difference with AX version
  11. Replies
    12
    Views
    997

    Too much beer I lost link ...

    Too much beer I lost link

    http://gofile.me/32wEs/gICnKFEek
  12. Replies
    6
    Views
    381

    Thanks Orion, BqlGrid working perfectly Digo,...

    Thanks Orion, BqlGrid working perfectly

    Digo, in VykonPro module I don't find Global Commands
  13. Replies
    6
    Views
    381

    Find a method, just play with ProgramService,...

    Find a method, just play with ProgramService, edit slot and facet with in2 unless if there are already override through in1...
  14. Replies
    6
    Views
    381

    AX multiple override and table

    Hi guys,

    Is there a method to override many points through BQL instead of create many links?

    Also is there a way to create a table binding with possibility to change value through table?
    ...
  15. Replies
    0
    Views
    223

    N4 Schedule bug (Shifted)

    ​Hi all,


    I'm using N4 supervisor (4.1.27.16.1.36) and I have a problem with schedule through HTML5 interface.

    Every time I save all schedules are shifted one day before!

    686871

    Save
  16. Be careful ! HIDE YOUR PUBLIC IP ADDRESS ON...

    Be careful !

    HIDE YOUR PUBLIC IP ADDRESS ON YOUR PRINTSCREEN!!! :deadhorse::censored::argue:
  17. Replies
    12
    Views
    997

    Holiday time sorry Follow link for N4 module ...

    Holiday time sorry

    Follow link for N4 module

    http://gofile.me/32wEs/JghHATEdm

    Have fun
  18. Replies
    12
    Views
    997

    VykonPro N4 for you

    Hi guys,

    if anyone need VykonPro for N4 send me your email and give me a beer :cheers:
  19. Replies
    1
    Views
    394

    https://www.tridiumeurope.com/storage/downloads/Tr...

    https://www.tridiumeurope.com/storage/downloads/TridiumEuropeResource_niagara4faqs_1456327045.pdf

    Will Sedona be supported in Niagara 4?
    Yes. Tridium are committed to the development of a Sedona...
  20. Replies
    1
    Views
    394

    Sedona TXS N4

    Hi guys,

    Anyone know if Tridium is working on Sedona TXS for N4 ?

    Thanks
  21. Replies
    10
    Views
    894

    1 - Niagara discover from AX to N4 doesn't work,...

    1 - Niagara discover from AX to N4 doesn't work, you must add them manually
    2 - Can't import schedule from AX to N4, you must create schedule in N4 supervisor and add them manually in AX
    3 - You...
  22. Replies
    10
    Views
    894

    I challenge you to create hierarchies after...

    I challenge you to create hierarchies after e-learning course! This course is a joke...

    N4 Good
    - HTML5 (client)
    - Hierarchy
    - UI improve
    - Web dashboard
    - Template
    - Search function
  23. Replies
    5
    Views
    398

    Good luck, Alerton products is outdated. Hint:...

    Good luck, Alerton products is outdated.
    Hint: Don't go with this products,find another products from 21st century and have fun!
  24. http://img11.hostingpics.net/pics/662981ScreenShot...

    http://img11.hostingpics.net/pics/662981ScreenShot012416at0540PM.png
  25. Hi, What you need exactly? For 24V relay,...

    Hi,

    What you need exactly?
    For 24V relay, you just need to put an output Point and configurate in Binary Output like this:

    https://drive.google.com/file/d/0B_6qZCCPvCExTXpBWjZocmxrbTA
  26. Replies
    46
    Views
    11,254

    Anyone have vykonpro module for n4 ?

    Anyone have vykonpro module for n4 ?
  27. Replies
    2
    Views
    389

    I checked this spec. I use my ddc control not...

    I checked this spec. I use my ddc control not CP-8301.

    I think I must replace all system by belimo or honeywell motor.

    Thanks
  28. Replies
    2
    Views
    389

    Barber-Colman actuator

    Hi guys,

    I have an economizer actuator Barber Colman MP-481-0-0-2 and I want to know if I can modulate in 2-10Vdc?

    On specification sounds like yes but I'm not sure
    Specification link


    ...
  29. Replies
    1
    Views
    898

    Job done! All valves through one program. For...

    Job done!

    All valves through one program. For this moment my program is not really optimize but if someonw needs this program, send me an email.

    ...
  30. Replies
    1
    Views
    898

    Can2Go Spartan Valve

    Hi Everyone,

    I have a Can2Go gateway and 5 Spartan valve (ME8390), I'm using Can2Go program (ME8330 Direct Acting FLP (Bi-Directional EnOcean Valve Actuator) v1.4.1).

    My question is how can I...
  31. Replies
    5
    Views
    828

    Problem solved. I sent serial number and date...

    Problem solved.

    I sent serial number and date to AAM and they sent me a master password level 3.

    I think they should add feature to restrict the upload of the app without an operator level...
  32. Replies
    5
    Views
    828

    My problem is I change level operator (3 to 1)...

    My problem is I change level operator (3 to 1) and after to upload configuration file import and export SD option disappear from BBC menu I can't do anything without this option...

    There is a...
  33. Replies
    5
    Views
    828

    BBC-SD Factory Reset

    Hi all,

    How can I make a factory reset to my touscreen BBC-SD?

    Thanks
  34. Replies
    7
    Views
    1,121

    Looking for ultrasonic flow meter

    Hi guys,

    I'm looking for a ultrasonic flow meter (BACnet or modbus or pulse) for a 3'' piping.
    Budget and delay are tight.

    Thanks.
  35. Replies
    34
    Views
    4,287

    Try to reset your Jace. Connect your PC to Jace...

    Try to reset your Jace.
    Connect your PC to Jace through Shell mode and select Reboot
    During boot, a message will appear like:
    Press any key to restore factory defaults
  36. Replies
    34
    Views
    4,287

    And What is your workbench and Jace 7 version ?

    And What is your workbench and Jace 7 version ?
  37. Replies
    34
    Views
    4,287

    Your error window when you try to enter in your...

    Your error window when you try to enter in your platform like this

    http://img11.hostingpics.net/pics/186798ScreenShot362.png
  38. Replies
    34
    Views
    4,287

    Can you send Details from error window

    Can you send Details from error window
  39. Allen Bradley Micro850 Modbus Error

    Hi all,

    I have a AB Micro 850 and I want transfer data in modbus TCP but I have an error on my MSG_MODBUS2 module

    ErrorID 33 (A bad MSG file parameter exists)
    SubErrorID 37 (???)

    Anyone...
  40. Replies
    4
    Views
    642

    No first installation and no message to create...

    No first installation and no message to create user
  41. Replies
    4
    Views
    642

    KMC BACstage Password

    Hi,

    I installed KMC BACstage. What is the Master Operator Name/Password??

    Regards.
  42. Replies
    0
    Views
    504

    FX7 Memory glitch

    Hi all,

    I have a FX-7 with BACnet network (23 Devices (Alerton VAV), 20 pts each), 2x N2 Network (30 Devices each (VMA), 20 pts each).

    The problem is sometime I lost station (reboot).

    I...
  43. Replies
    18
    Views
    2,987

    The building is 25 years old. I will purpose an...

    The building is 25 years old. I will purpose an air balancing.



    Yes I think I can add one static pressure for each floors, I will move the pressure sensor on 2/3 of duct. Why do you see wild...
  44. Replies
    18
    Views
    2,987

    We want centralize all tenant room, among other...

    We want centralize all tenant room, among other things, for high and low temperature watch.




    Good point. But what can I do with my chiller if I slowdown the VFD?

    It's a chiller Trane RTWD...
  45. Replies
    18
    Views
    2,987

    Can you to be most clear in your explaining? I...

    Can you to be most clear in your explaining?

    I have a boiler and chiller system.
    I calculated energy saving and If I stop the AHU systems all the night, I save $20,000.00 by year. I will paid my...
  46. Replies
    18
    Views
    2,987

    Dual Duct + VFD

    Hi All,

    I have a building 6 Floors with 2 HUA (Perimeter: Cooling Only; Interior: Dual Duct).
    I want stop the units during the night and weekend but sometime there are some tenants on some floor...
  47. Replies
    6
    Views
    1,258

    There is not DDC, just 4 stages command. The...

    There is not DDC, just 4 stages command.
    The quoting is $ for add Tekmar indoor/outdoor controller.

    Suppose to maximize the performance of the boiler and establish savings on gaz consumption
  48. Replies
    6
    Views
    1,258

    No, Raypak is existing

    No, Raypak is existing
  49. Replies
    6
    Views
    1,258

    Raypak Controller

    Hi all,

    I have a boiler Raypak model H9-2342B, the DDC control the 4 stages. A contractor recommend me to install a boiler controller like Tekmar Indoor/Outdoor, 4 stages. What you think about...
  50. Replies
    41
    Views
    8,627

    30P is correct but so so compare FG series

    30P is correct but so so compare FG series