    1 leg of of 460 is 277 vots. If the motor's fla...

    1 leg of of 460 is 277 vots. If the motor's fla is rated for more than the control then definitely use a relay, if not it should work. I've used one for a similiar application before and have had...
  2. Replies
    21
    Views
    1,667

    Is the outdoor unit above the indoor and if it is...

    Is the outdoor unit above the indoor and if it is are there traps installed in the line set?
  3. Replies
    11
    Views
    2,470

    You should be only braking one leg, so it should...

    You should be only braking one leg, so it should be ok. Just make sure the amp draw for the motor isn't too high for the control.
  4. I went to the Atlanta class about a 1.5 years...

    I went to the Atlanta class about a 1.5 years ago. Great instructor and class. Just bring a lap top if you have one.
  5. Replies
    2
    Views
    1,926

    Thanks, Mr. Bill. The FAU will not reset. I was...

    Thanks, Mr. Bill. The FAU will not reset. I was thinking of replacing the board. I just wanted to check with someone that has seen that code before. I am more of a commercial tech and do not have...
  6. Replies
    2
    Views
    1,926

    Twinning fault code for a Rheem Fau

    Does anybody have an idea what this is? Rheem FAU model # RGPH 07namgr Ser# DF5D307F389804165 The FAU is not twinned with another one. Anyhelp would be great.
  7. Replies
    2
    Views
    570

    York Question

    Has anyone ever seen a line drier on the discharge line of a york heat pump. I've seen it twice with with two grounded compressors. I know a muffler can go there but always thought a line drier was...
  8. Replies
    6
    Views
    1,252

    How old is the screw and when was the last time...

    How old is the screw and when was the last time the oil filters were done. If possible check for pressure drop across, should be a port at the compressor and after the oil separator. Not saying...
  9. Well the loop shouldn't have a high temp issue...

    Well the loop shouldn't have a high temp issue with the water in heating ever really and oil separation typically happens with cooler temps. I would call out a professional to have a look at them...
  10. Replies
    7
    Views
    2,380

    x2

    x2
  11. Replies
    14
    Views
    1,221

    Actually a ductless split is becoming the way to...

    Actually a ductless split is becoming the way to go. Check City Multi by Mitsubishi. They have units that go up to at least 20 ton and more. You can put up to i think 16 air handlers on one...
  12. Replies
    30
    Views
    3,471

    Actually i weighed the charge in and after the...

    Actually i weighed the charge in and after the box came down to temp and it ran for a day the head pressure came down on it's own. Maybe R414B takes a little bit for it to mix with the oil was what...
  13. Replies
    30
    Views
    3,471

    Well I thought I would post and let everyone know...

    Well I thought I would post and let everyone know how it went. Started 1 leak turned in to 3 or 4. After quite a long evacuation(i triple evaced since the leaks seemed to be original)the unit is...
  14. Replies
    30
    Views
    3,471

    R12 to Hotshot

    I'm going to try to do a favor for a friend that's opening a small bar and he needs his make up line fixed. I plan on converting the old sucker over to r414b and fix a small leak. The question is,...
  15. Replies
    5
    Views
    879

    If you zone the u/s and d/s, a smaller unit will...

    If you zone the u/s and d/s, a smaller unit will do just fine as you will not be using all of it all the time because the d/s does not have the load as the u/s. So the zoning system will allow your...
  16. Replies
    26
    Views
    2,181

    You have a dangerous situation there. If you are...

    You have a dangerous situation there. If you are a H/O you should call out a professional to diagnose the situation and turn the power off to the unit. Good luck.
  17. Replies
    21
    Views
    5,006

    Actually i haven't used a P66 either, I guess the...

    Actually i haven't used a P66 either, I guess the one I was referring to was the P70 type controller. As far as cost i'm not sure they always been on the shelves at the shops I've worked at and...
  18. Replies
    9
    Views
    775

    At this point if u have access to parts, you...

    At this point if u have access to parts, you could of have paid a tech to diagnose it and then and gone and got the parts. Call a professional before something bad happens. I wish i could help, but...
  19. Replies
    21
    Views
    5,006

    I've messed with those head pressure controllers...

    I've messed with those head pressure controllers before. Id scrap it and go with the Johnson Controls one that John Dalton mentioned, they even have t's that screw on to the liquid line port so you...
  20. Replies
    10
    Views
    2,839

    For couriosities sake, how did u bypass the board...

    For couriosities sake, how did u bypass the board for a gas heater, the ignitione module is built in the board on that particular furnace. Either way
    i would call out a pro to look at it.
  21. Replies
    6
    Views
    819

    Is it like a wall mountd unit or cased upflow?

    Is it like a wall mountd unit or cased upflow?
  22. Can we get a thread lock on aisle 9 please? ...

    Can we get a thread lock on aisle 9 please? Wasn't this topic already locked or was it the star network?
  23. Replies
    9
    Views
    1,016

    Did i make a funny? I missed it, doh!:)

    Did i make a funny? I missed it, doh!:)
  24. Replies
    18
    Views
    1,705

    There are solutions if you want to maintain a...

    There are solutions if you want to maintain a constant humidity level between x% and x%, the infinity series from carrier would be one such example, visit carriercorp.com if you wnat to find out...
  25. Replies
    25
    Views
    1,730

    I usually cut the discharge side of the valve and...

    I usually cut the discharge side of the valve and sweat the rest off.
  26. Replies
    25
    Views
    1,730

    It was his first one and he did it by himself. I...

    It was his first one and he did it by himself. I think if I remember right when i did my first one I had a little debate over how I was going to get that sucker out and back in, the unit was only a...
  27. Replies
    25
    Views
    1,730

    I am not bagging jsut curious which way you went,...

    I am not bagging jsut curious which way you went, I've always found it easier to cut them out also, but have had several debates over this. that's why I asked. Glad your job worked out.
  28. Replies
    25
    Views
    1,730

    yeah, 4.5 hours doesn't sound bad. Did you sweat...

    yeah, 4.5 hours doesn't sound bad. Did you sweat it off or cut it out?
  29. Replies
    26
    Views
    5,591

    Were you out there on a no heating call? Hope...

    Were you out there on a no heating call? Hope you get commission.;)
  30. Replies
    26
    Views
    8,752

    Reminds me of the first time i saw a FAU unit not...

    Reminds me of the first time i saw a FAU unit not converted. First thing that seemed wrong was the knob on top of the gas valve dripping down the side of the valve and the melted shielding on flame...
  31. Replies
    9
    Views
    1,016

    Thanks for the welcome you guys. The question i...

    Thanks for the welcome you guys. The question i am about to ask probably belongs in the newbie post, so i'll ask it here. For some of you guys that have been around the block with heavier end...
  32. Did you say in a previous post that the duct...

    Did you say in a previous post that the duct going u/s is squished? How squished? If you added a duct booster after the squish and it doesn't push air, it's possible it doesn't have anything to...
  33. Rmalarm, in my experience the best solution would...

    Rmalarm, in my experience the best solution would be if the wire feels like it is free in the wall(not stapled), tie on some stat wire and pull it through. If the previous h/o added the wire after...
  34. :)

    :)
  35. Replies
    57
    Views
    7,974

    Question for gsxrsquid or clippertech, do you...

    Question for gsxrsquid or clippertech, do you release trhe hole can into the charge? I am curious because i am wondering if the contents that aren't used to repair leaks are left in the charge and...
  36. Replies
    10
    Views
    923

    Did you check ra temp at the ra plenum on the air...

    Did you check ra temp at the ra plenum on the air handler? Is there fresh air installed, did you check for retrun air leaks for low s/a temp.
  37. Unfortunately the phone wire is no good for 24vac...

    Unfortunately the phone wire is no good for 24vac applications. You could always try tying on a piece of 18 gauge stat wire to it and trying pulling the right wire through, if the phone wire isn,t...
  38. Replies
    57
    Views
    7,974

    So if u have no strip heat and it was heating it...

    So if u have no strip heat and it was heating it wasnt bone dry, especially if its been really cold where u live. If he told you that he wanted to return in a month to check the charge he either...
  39. Replies
    8
    Views
    830

    A 38YDB036 is an outdoor unit, is it the heatpump...

    A 38YDB036 is an outdoor unit, is it the heatpump outside you are referring to or the air handler inside.
  40. I aree with Marks reply concerning carrier,...

    I aree with Marks reply concerning carrier, lennox, tranes zoning systems. When i adjsut a bypass duct or barometric relief duct, usually i will run all the zones open and fan on high and adjsut the...
  41. Replies
    9
    Views
    1,016

    Newbie Checking In

    Hi all, Ive been checking out the forum for a couple days and decided to register. I have about 13 years in the industry starting w resi and now with larger commercial stuff. Just though I'd make a...
  42. Replies
    57
    Views
    7,974

    Hers my 2 two cents, the cost of leak check will...

    Hers my 2 two cents, the cost of leak check will be payed after you get your electricity bill for a heat pump that is heating your place low on charge, especially if you have strip heat installed. ...
  43. Replies
    2
    Views
    601

    You could purchase a magnehelic gauge and use...

    You could purchase a magnehelic gauge and use that, or a manometer with a 10" wc scale or lower will work.
Results 1 to 43 of 60
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event