    Yes This is something that I wondered if anyone...

    Yes This is something that I wondered if anyone would bring up. I believe that installation error has much more to do with problems with hvac systems than the actual equipment brand does.
  2. Replies
    5
    Views
    950

    Laugh, You are agreeing with me it sounds like. ...

    Laugh, You are agreeing with me it sounds like. I have several suppliers hounding me to buy their equipment and they all say how much better their equipment is than the other guy but to be honest I...
  3. Replies
    5
    Views
    950

    What is the best equipment out there.. I mean in...

    What is the best equipment out there.. I mean in a Value sense. I have installed several different brands of Furnace and AC equipment and to be very honest I have really seen the huge difference in...
  4. Replies
    69
    Views
    5,662

    I add freon for the Linset over the 15'. As for...

    I add freon for the Linset over the 15'. As for the coil I used a 5 ton coil and a 4 ton condenser. The larger coil requires additional freon.

    This is straight out of the manual tells you...
  5. Replies
    69
    Views
    5,662

    Yeah I sent something did you get it?

    Yeah I sent something did you get it?
  6. Replies
    69
    Views
    5,662

    Ok I re-checked it was 45 inside and 43 outside. ...

    Ok I re-checked it was 45 inside and 43 outside. Maybe I didnt have probe on tightly before.
  7. Replies
    69
    Views
    5,662

    Wait a minute I went back down to my airhandler...

    Wait a minute I went back down to my airhandler Now it is 45 leaving the coil mabye I didnt wait long enough after taping my probe on. Let me check outside..
  8. Replies
    69
    Views
    5,662

    How can that suction line lose that much temp...

    How can that suction line lose that much temp between the evap and cond Shouldnt it be gaining temp?
  9. Replies
    69
    Views
    5,662

    Hey jult I was being sarcastic to his stupid...

    Hey jult I was being sarcastic to his stupid homeowner post I am a Tech and am looking for some help.. I appreciate all the help you are giving me. Seems Prod is just being a prick though.
  10. Replies
    69
    Views
    5,662

    Hey duc read my post.. I know how to charge it I...

    Hey duc read my post.. I know how to charge it I am trying to clarify why it is if you charge the system according to the manual.... Eh.. Read the post I have written it about 8 times. I have only...
  11. Replies
    69
    Views
    5,662

    Yes I do

    Yes I do
  12. Replies
    69
    Views
    5,662

    Hey Jult are you still around

    Hey Jult are you still around
  13. Replies
    69
    Views
    5,662

    Yeah Ok Prod... Me too. The subcooling value is...

    Yeah Ok Prod... Me too. The subcooling value is not on the nameplate either..
  14. Replies
    69
    Views
    5,662

    How do you charge with TXV? Subcooling? What...

    How do you charge with TXV? Subcooling? What is the desired Figure or does it change with conditions as well. Do I need a chart for this or is there a standard subcooling value to shoot for?
  15. Replies
    69
    Views
    5,662

    Yeah This is what I do sometimes. However I am...

    Yeah This is what I do sometimes. However I am constantly told by so called experts that you need to do what the manual says. From my experiences I think that is crap. I am trying to learn you...
  16. Replies
    69
    Views
    5,662

    Jult My ST is 44 EST is 64 What would...

    Jult

    My ST is 44
    EST is 64

    What would you say my SH should be based on the charts you use and the info I have provided. Also do you think the a smaller oriface would be better or lower...
  17. Replies
    69
    Views
    5,662

    Hey Prod. I did not blow it off. It just...

    Hey Prod.

    I did not blow it off. It just seems something as simple as putting a certain charge in condenser when it leaves the factory is not rocket science. And from my on experiences out of...
  18. Replies
    69
    Views
    5,662

    Silver solder is acceptable for R-22 systems. On...

    Silver solder is acceptable for R-22 systems. On higher pressure systems it is not. I have always used it, and every contractor around here does as well. Silver solder is much stronger than 50/50...
  19. Replies
    69
    Views
    5,662

    Call A pro? What do you mean by this. I am...

    Call A pro? What do you mean by this. I am learning, I have been to training on Heil and Trane, Do I know everything... Ah... No I am trying to learn. Are you a pro? Once you were where I am at....
  20. Replies
    69
    Views
    5,662

    The little overflow or balancing line on the Txv...

    The little overflow or balancing line on the Txv is what I am talking about being brazed.
  21. Replies
    69
    Views
    5,662

    And another thing.. I ordered my system with a...

    And another thing.. I ordered my system with a Txv valve. Since it was Luxaire the TXV came seperate and I was in a hurry because I had company coming for the 4th. And I silver solder all of my...
  22. Replies
    69
    Views
    5,662

    What is the desired Delta t over the coil? It is...

    What is the desired Delta t over the coil? It is hard to check it unless I drill a hole in the plenum. Is there any OEM chart available for luxaire units.. Knowing the properties of freon and the...
  23. Replies
    69
    Views
    5,662

    Oh.. The CT was 89F sorry.. What is EST? As...

    Oh.. The CT was 89F sorry.. What is EST?

    As far as the amount added I added .7 oz for every Foot over 15. The Coil/Condenser match said to add 15oz and I had to add 14oz for lineset.

    I am...
  24. Replies
    69
    Views
    5,662

    Prod... I am unsure as I did not remove all of...

    Prod... I am unsure as I did not remove all of the freon and weigh it. ( The Freon Shipped within the condenser..)
    However I am sure that it seems nomatter the brand of equipment we install when...
  25. Replies
    69
    Views
    5,662

    I only have one OEM Chart. I use it for...

    I only have one OEM Chart. I use it for everything. Even though it is not Ideal It is much better than most all of my competidors who many of them dont even evacuate the system after the...
Results 1 to 25 of 28
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event