  1. any part on that system could fail, it's a...

    any part on that system could fail, it's a machine.
    not worth worrying about.
  2. #1

    #1
  3. Lennox had some weird serial #s up until the...

    Lennox had some weird serial #s up until the 70's, that looks like one of them.

    i would plan on changing the lines.
  4. Replies
    37
    Views
    1,582

    i sent a loose dog on his way yelping the same...

    i sent a loose dog on his way yelping the same way once.
  5. as the installer and the guy who has to go back...

    as the installer and the guy who has to go back and fix it when it breaks i have always been in the habit of looking for stuff that could be a problem.
    lines touching and rubbing through each other...
  6. Replies
    4
    Views
    231

    package unit will be fully charged from factory....

    package unit will be fully charged from factory.
    needs to be checked on start up in case of a leak.
  7. Replies
    4
    Views
    231

    most units ship with charge for 15' of lineset...

    most units ship with charge for 15' of lineset and matching coil.
    installer must balance charge at start up.
  8. Replies
    1
    Views
    148

    with what it would cost to run the well it would...

    with what it would cost to run the well it would never pay for itself unless you are already watering landscape as much as a/c runs.

    it would not harm a/c as long as you are not restricting air...
  9. contact Trane directly as the consumer and give...

    contact Trane directly as the consumer and give them that argument.
    stop back and let us know how you make out.
    i don't disagree with you and i really don't like Trane equipment so i'm not...
  10. did you close off the vent when you sucked out...

    did you close off the vent when you sucked out with shop vac?
  11. installer should have checked for any rub points...

    installer should have checked for any rub points at start up.

    Trane's obligation is to provide a replacement part.
  12. Replies
    4
    Views
    177

    low speed for heat, high speed for cooling. it...

    low speed for heat, high speed for cooling. it starts on whatever speed it is going to run on.
  13. Replies
    12
    Views
    549

    change the filter/ drier again and cut back on...

    change the filter/ drier again and cut back on the cap tube.
    make sure the cap tube is clear where you cut it back to. had a true beer box wax up the cap tube all the way to the evap.
  14. Replies
    22
    Views
    1,188

    are you required to have the 120v service outlet...

    are you required to have the 120v service outlet on every job now? only time we are required to have it is new construction or if house did not have A/C before.
  15. Replies
    10
    Views
    392

    in 40 years we have never anchored a unit to the...

    in 40 years we have never anchored a unit to the pad, that's what gravity is for. :whistle:

    some codes do require it depending on where you live, give your location and maybe someone local will...
  16. Replies
    7
    Views
    455

    Lennox CBX25 blower coils 52.5" for 5 ton, ...

    Lennox CBX25 blower coils 52.5" for 5 ton, shortest Lennox makes
  17. Replies
    4
    Views
    292

    whens the last time you had the unit serviced and...

    whens the last time you had the unit serviced and the charge checked?
  18. take your prices out, not allowed but...

    take your prices out, not allowed but damn........:whistle:

    like previous post get senior tech or another company in there.
  19. Replies
    21
    Views
    2,003

    gotta watch them mexmican lennox units.

    gotta watch them mexmican lennox units.
  20. Replies
    21
    Views
    2,003

    "if you're not bleeding you're not working hard...

    "if you're not bleeding you're not working hard enough" Dad
  21. Replies
    11
    Views
    393

    i don't think it would, there would still be...

    i don't think it would, there would still be water in trap.
  22. Thread: Test IV

    by t527ed
    Replies
    2
    Views
    132

    i was getting it earlier before the site went...

    i was getting it earlier before the site went down.
  23. Replies
    7
    Views
    467

    must have been pretty bad, i was getting...

    must have been pretty bad, i was getting redirected too. started yesterday but thought it must be on my end.

    as long as the site was down it must have taken a while to clean out.:gah:
  24. years ago the factory fittings on many a/c...

    years ago the factory fittings on many a/c systems were compression fittings, if done properly it will last a long time.

    i have a torch so i have never made a repair like that but if it was a...
  25. Replies
    2
    Views
    188

    :ditto: we have installed a couple of the Lennox...

    :ditto: we have installed a couple of the Lennox mini splits, seem as good as anything else........so far.