  1. Replies
    10
    Views
    441

    I usually convert it to txv and im done..

    I usually convert it to txv and im done..
  2. I'm in Texas I want to go to Florida Sent me...

    I'm in Texas
    I want to go to Florida
    Sent me a ticket.Lol
  3. Replies
    9
    Views
    390

    Agree with rundawg.. Ohm out DT.

    Agree with rundawg..

    Ohm out DT.
  4. Replies
    29
    Views
    907

    Dirty coil is probably your problem. If you have...

    Dirty coil is probably your problem.
    If you have a static pressures close to .5 across that coil, air flow start to be unstable.
    Condensate can actually fly off the coil at those pressures.
  5. Thread: Bryant txv

    by shaka
    Replies
    188
    Views
    13,364

    mr Bill How are you converting it to piston?...

    mr Bill

    How are you converting it to piston?
    do you have a fitting to connect to male thread on the coil?
  6. Thanks Ryan.

    Thanks Ryan.
  7. LENNOX Dealers. Can you tell me if this is an approved match?

    Condenser...
    M# 14ACX-060-230-11

    Evap coil on furnace

    M#CX34-49C-6F-1


    Evap coil is leaking and I need to replace but need to make sure it's an approved match
    Thank you
  8. Replies
    17
    Views
    1,276

    Bez if you have the extra wires like I ask that...

    Bez
    if you have the extra wires like I ask that means your motor is after market.
    I you changed it and installed the same horse power, that motor will mess up.
    Like timjimbob said the oem will...
  9. Replies
    15
    Views
    978

    Is that mean according to watt to speed ratio...

    Is that mean according to watt to speed ratio your fan is actually running at 1150 at high speed?
  10. Replies
    17
    Views
    1,276

    Do you remember if the motor had the extra wires...

    Do you remember if the motor had the extra wires to change rotation?
  11. Replies
    1
    Views
    642

    Do you have pictures You can send to my email...

    Do you have pictures

    You can send to my email on my profile thanks
    I'm interested
  12. Wow 2.5 amps and cools my garage Do you have...

    Wow 2.5 amps and cools my garage
    Do you have model number.
    How much was it
  13. Yes I do feel hvac contractor should be the one...

    Yes
    I do feel hvac contractor should be the one installing the water heater.
    we can handle the the install and the equipment in case it goes down.

    I guess if the plumber install it, he would...
  14. If the water heater was indoor and it's winter,...

    If the water heater was indoor and it's winter, that might get the house too cold.

    I guess you could run just the auxiliary heat in the winter.
  15. So the new unit uses 134a or 410? How old is...

    So the new unit uses 134a or 410?
    How old is your water heater?
    Do you like it?
  16. Heat pump water heater, are we going to work on water heater now?

    Do they call a plumber? I don't think so

    I was just looking at a heat pump water heater
    Any time now we will be working on the water heater too.

    I was thinking of installing one for my...
  17. Thread: No superheat

    by shaka
    Replies
    31
    Views
    1,895

    What's your pressures.? SH,SC I don't see how...

    What's your pressures.? SH,SC
    I don't see how you have a restriction with no superheat.

    We need more info
  18. Thread: Can't find leak

    by shaka
    Replies
    26
    Views
    1,953

    Too bad you can't pressurize the condenser then ...

    Too bad you can't pressurize the condenser then
    Throw it in a swimming pool :grin2:
  19. You don't need to remove the mineral oil. I...

    You don't need to remove the mineral oil.

    I have a walk in cooler with approx 50/50 of MO and Poly
    Been running for over 5 years
  20. Why do feel you have to flush when you convert to...

    Why do feel you have to flush when you convert to 410?
  21. Yup they got into your pocket. I have never...

    Yup they got into your pocket.

    I have never used any RX11
    Not even on burn out.
  22. Replies
    7
    Views
    1,252

    I think I have 3 diff one But I don't use any of...

    I think I have 3 diff one
    But I don't use any of them. Lol
  23. Replies
    17
    Views
    1,165

    Ohh forgot to tell you if the resistance value...

    Ohh forgot to tell you if the resistance value way off the specs
    Compressor is bad, you need to replace it.

    Ignore my last post where I tell you to calculate the back emf..
    That's not...
  24. Replies
    17
    Views
    1,165

    Also get model number of the compressor, Check...

    Also get model number of the compressor,
    Check the original specs on compressor
    Compare winding resistance,
    May have weak winding causing potential relay not to drop out right away. ( cabbboomm)
    ...
  25. Replies
    17
    Views
    1,165

    What's the voltage across run cap.? Run usually...

    What's the voltage across run cap.?
    Run usually goes out by high voltage issues,( cheap cap)
    Start cap usually goes out due to short cycling,
    So check make sure it's not short cycling.
    Check...