Search:

Type: Posts; User: 2frosty

Page 1 of 7 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    1
    Views
    382

    I got it working. Turns out when he put stat on,...

    I got it working. Turns out when he put stat on, he had a small leak on indexing line inside of wall. Once I fixed that, it worked fine.
  2. Replies
    1
    Views
    382

    classroom ventilator

    Im having some trouble with the occupied/unoccupied control of the fan in a classroom ventilator. The PE DPST switch was replaced last year and now the fan only comes on with a call for heat from the...
  3. Thread: email

    by 2frosty
    Replies
    1
    Views
    362

    email

    my administrator set up an email account for the whole company through yahoo but I cant access mine. she made the "craig@westclimatecontrol.com" user name and made up a password for me but it wont...
  4. Ive been using the Accuprobe for 2 years and have...

    Ive been using the Accuprobe for 2 years and have had great luck with it. It has detected leaks that others havent. I havent had to use the nitro as much for small leaks either.
  5. Replies
    49
    Views
    3,373

    For the last 5 years or so Ive been using a...

    For the last 5 years or so Ive been using a Craftsman 3.6 volt in line driver that bends in the middle to a 45 degree angle. It was 20 bucks and Kmart carries them now. Never have to worry about...
  6. Thread: Taylor 754-27

    by 2frosty
    Replies
    1
    Views
    984

    wrong forum

    did I post this in the wrong forum?:confused:
  7. Thread: Taylor 754-27

    by 2frosty
    Replies
    1
    Views
    984

    Taylor 754-27

    I'm new to working on soft serve equipment, although ive made a lot of cones as a kid. Ate 'em too:D customer called to have us charge his 754 air cooled. He had talked to his go to guy, Taylor...
  8. Thread: Maxitrol Info

    by 2frosty
    Replies
    7
    Views
    2,256

    no i actually work for West. enjoy the industrial...

    no i actually work for West. enjoy the industrial side of the trade. been doing res for a while and like the change of pace with comm refer and industrial burner maint.
  9. Replies
    48
    Views
    16,672

    they had issues a while back with exhaust...

    they had issues a while back with exhaust sounding like a train in the basement. turns out the cork gasket at the outlet of the inducer was upside down, leaving part of the cork material in the...
  10. Thread: Maxitrol Info

    by 2frosty
    Replies
    7
    Views
    2,256

    I work up in Petoskey for a climate control...

    I work up in Petoskey for a climate control company. We maintain a lot of direct fired equipment using maxitrol amplifiers too.
  11. Thread: Maxitrol Info

    by 2frosty
    Replies
    7
    Views
    2,256

    traverse city

    hey traversetech, where is this Industrial air? I live about an hour from TC and am just curious. I work on a lot of Rapids and other direct fired MUA in antrim, charlevoix and emmet counties. Did...
  12. Replies
    16
    Views
    2,859

    danger?

    when is the potential for arc flash present? just when a contactor or disconnect is energized, or even while equipment is running? i went to the safety crib at a steel foundry i do maintenance for...
  13. Replies
    23
    Views
    2,760

    I've never seen or heard of this happening to...

    I've never seen or heard of this happening to this degree before. Been in the trades for over a decade and never even heard of this danger or how to protect oneself from it. i do a lot of work in a...
  14. Replies
    8
    Views
    675

    yeah there is a manual lever to override unocc...

    yeah there is a manual lever to override unocc temps. i raised the unocc pressure just to be sure and account for line friction and leaks but cant remember if i put a gauge on the main coming into...
  15. Replies
    8
    Views
    675

    thanks guys

    yeah a sequence of ops would be helpful. i've got the basic intentions figured out, just not fully confident in the complete operation and capabilities of the systems and i hate not knowing...
  16. Replies
    8
    Views
    675

    its the air side thats getting me. the barber...

    its the air side thats getting me. the barber colman stats are quite 'busy" in my opinion. just too sensitive and have too much going on-way too many parts, ports, bi-metals, flaps etc. jci looks...
  17. Replies
    8
    Views
    675

    old school pneu problem

    I'm working in an older high school with barber colman t-stats and pe ep switches. its all DA, 15/20 psi(occ/unocc), with American Air Filter and Trane unit ventilators. been having trouble finding a...
  18. Thread: forums

    by 2frosty
    Replies
    0
    Views
    447

    forums

    has anyone heard of a forum for Rapid Air industrial make up air units. Ive been to rapid engineering's web site and have googled rapid air forums to no avail. did not know that rapid air is also an...
  19. Replies
    18
    Views
    2,002

    you need to check each evap pressure and line...

    you need to check each evap pressure and line temp seperately . if one is normal or a little low and the other is high, you wont see it at the compressor.
  20. Replies
    3
    Views
    614

    yeah im a pro and i logged in like i usually do....

    yeah im a pro and i logged in like i usually do. the gas pressure is a little low due to the reulator being 25ft in the air and a hot production line beneath it. its been that way since it was...
  21. Replies
    3
    Views
    614

    burning at orifice

    i am working on an Enerco Technical Products vent free radiant space heater.
    it is a milivolt system and starts just fine but after a few minutes poof it burns back to the orifice. i checked the...
  22. Thread: carbonators

    by 2frosty
    Replies
    10
    Views
    772

    it is a KW6000 carbonator for a soda gun in a bar.

    it is a KW6000 carbonator for a soda gun in a bar.
  23. Thread: carbonators

    by 2frosty
    Replies
    10
    Views
    772

    carbonators

    to be honest len i have no idea. next to the condenser deck is an insulated tank into which the cap tube and suction line come out. there is an sj cord, a remote temp bulb and 6 water lines. 2 lines...
  24. Thread: carbonators

    by 2frosty
    Replies
    10
    Views
    772

    was asked to look at a soda carbonator today by a...

    was asked to look at a soda carbonator today by a regular refrigeration customer. R-22 system by "K-WAVE" or similar. model no. KW6000. cap tube system with what looks like a tube in tube style...
Results 1 to 24 of 168
Page 1 of 7 1 2 3 4
Comfortech Show Promo Image