  1. Replies
    9
    Views
    906

    The tech overcharged more than 2x's the amount...

    The tech overcharged more than 2x's the amount needed. I reclaimed 5lbs of R22 out of the system. I had never seen an overcharge so extreme. Thanks for the help,appreciated.
  2. Replies
    30
    Views
    1,929

    All set! You guys are great! You obviously know...

    All set! You guys are great! You obviously know the problem so no sense in stating it. I now know as well. Thanks guys.
  3. Replies
    30
    Views
    1,929

    I sent an email. Thanks.

    I sent an email. Thanks.
  4. Replies
    30
    Views
    1,929

    I am not an expert. Trying to get there some day...

    I am not an expert. Trying to get there some day however. I have never seen an overcharge of that capacity. I have myself overcharged slightly, but have never seen the outcome of a 5lb overcharge....
  5. Replies
    30
    Views
    1,929

    I have seen high pressure with plugged condeser....

    I have seen high pressure with plugged condeser. This is different. The compressor made a "whining" noise, then ran for about 10 seconds, and made then noise again. As it made the noise my guage...
  6. Replies
    30
    Views
    1,929

    Have you ever seen an overcharge, or any...

    Have you ever seen an overcharge, or any condition cause R22 spike to 500psi on startup? While the lowside not entering a vacuum.
  7. Replies
    30
    Views
    1,929

    tomarrow I am going to reclaim and charge it...

    tomarrow I am going to reclaim and charge it myself from scratch. A clog in the txv or filter would cause a low side vacuum I believe, so I am not leaning toward that, I hope its just an extreme...
  8. Replies
    30
    Views
    1,929

    I do not know everything there is to know..for...

    I do not know everything there is to know..for sure. That is why I posted. The only information I gathered was running pressures. The superheat was virtually noexistant. I had 120psi suction. So it...
  9. Replies
    9
    Views
    906

    the pressures were so high I shut it off very...

    the pressures were so high I shut it off very quickly. The superheat seemed non existant, the suction line was not getting cold to the touch. The liquid line however was not exceeding hot like it...
  10. Replies
    30
    Views
    1,929

    It is original, about 10 years old. I was going...

    It is original, about 10 years old. I was going to reclaim tomarrow and charge it from scratch. I have never seen pressures that high in a R22 system, I was wondering if anyone else had.
  11. Replies
    9
    Views
    906

    Heir 2.5 ton condenser help

    I showed up on the job after someone else tried to charge the system which he belived was low on charge. I put my guages on the unit, then turned it on. The high side pressure spiked to 500psi. the...
  12. Replies
    30
    Views
    1,929

    Help with R22 central air

    I went to help a friend today with a 2.5 ton Heir condenser. He tried to charge it, but had problems. I put my guages on it,turned it on and the High side spiked to 500 psi! It dropped alittle but...