  1. Replies
    36
    Views
    1,735

    Water Lines?

    Water Lines?
  2. Replies
    73
    Views
    2,353

    10 sh in cooling mode doesn't mean 10sh in heat...

    10 sh in cooling mode doesn't mean 10sh in heat mode. Heat mode uses a different expansion device. I'm not saying the comp couldn't have just failed due to nothing you did wrong.
  3. Replies
    20
    Views
    805

    Three phase motors will not have caps.

    Three phase motors will not have caps.
  4. Replies
    13
    Views
    1,214

    You look very proud of your machine! Phones...

    You look very proud of your machine! Phones actually take colored pictures.:grin2:
  5. That style diffuser may have a set of adjustable...

    That style diffuser may have a set of adjustable blades behind the ones we see. Can't tell from photo. Good point. Otherwise duct traverse and set cfm. Does the AHU fan have a VFD?
  6. All branch ducts are to have manual volume...

    All branch ducts are to have manual volume dampers. It's code in my area anyway. That's how air balance is done.
  7. Air balancer should set fan speed. Did you have...

    Air balancer should set fan speed. Did you have an air balance done? You should get a copy of report .
  8. Landlord especially should have service...

    Landlord especially should have service contracts. Filters should never be left up to tenants.
  9. Prices are not allowed but I'm sure the mods will...

    Prices are not allowed but I'm sure the mods will catch it and delete pricing. As far as workmanship send photos. What repairs were performed. If a coil box HAS to be cut open sheet metal patch and...
  10. Thread: Stupid Forum

    by ckartson
    Replies
    60
    Views
    1,772

    I don't get why you are so angry. All your...

    I don't get why you are so angry. All your questions were answered.
  11. Replies
    26
    Views
    964

    It's not supply air because the heat ex is after...

    It's not supply air because the heat ex is after that sensor. It is mixed air sensor because as was mentioned it does control econo but also controls second stage cooling when energized. This is a...
  12. PHM it's good to see a post from you and that...

    PHM it's good to see a post from you and that one's a doozy:grin2: I hope everything's ok.
  13. Replies
    5
    Views
    385

    Roof Top Unit, heat and air

    Roof Top Unit, heat and air
  14. Replies
    26
    Views
    968

    David! Are you out there, did you get amp draws,...

    David! Are you out there, did you get amp draws, was it over amping and going off on internal overload or motor protector.
  15. Replies
    21
    Views
    1,010

    I would have a pro look at it. It probably isn't...

    I would have a pro look at it. It probably isn't correct but need to see the outside termination also. Intake is supposed to be terminated above snow line but really you need to have a pro out there....
  16. Replies
    8
    Views
    965

    You said the actuator is connected to an AO...

    You said the actuator is connected to an AO already. Also 24 v connected to actuator through a DO. Sounds to me as if the actuator is enabled by the DO and controlled by the AO. Was it a replacement...
  17. Replies
    9
    Views
    886

    Bypass open.

    Bypass open.
  18. Replies
    744
    Views
    142,023

    What was wrong?

    What was wrong?
  19. Replies
    10
    Views
    595

    Ammoniadog, curious about what is detrimental...

    Ammoniadog, curious about what is detrimental about low amp draw? Also how low are you talking?
  20. Replies
    24
    Views
    1,932

    Outstanding job! When I worked on Trane equipment...

    Outstanding job! When I worked on Trane equipment for one company I had a resistance decade box. You exceeded that box. Only difference is the decade box could be used for other troubleshooting,...
  21. Replies
    27
    Views
    1,776

    GenesisRefrig, I also remember filling Styrofoam...

    GenesisRefrig, I also remember filling Styrofoam cups we R 12 back before reclaim when people would ask for a little freezone because there car was a little low. They would walk away with a cup of...
  22. A large hospital in the Cleveland area requires...

    A large hospital in the Cleveland area requires an open ceiling permit if we have to remove a ceiling tile. They don't argue the bill even though it may be three or four times more due to the legwork
  23. You got half a diagnosis. The other half would...

    You got half a diagnosis. The other half would have been amp draws. This would tell if all elements were energized. I would get a service contractor out if I am serious about buying.
  24. Replies
    6
    Views
    1,421

    Jogas, what #BV is keeping the fans on? Also if...

    Jogas, what #BV is keeping the fans on? Also if you think the wrong program was used look in Alerton standards for a parallel fan program. VAV box programs are usually selected from there.
  25. Replies
    62
    Views
    2,078

    I think you mean co sensors correct?

    I think you mean co sensors correct?
  26. Replies
    22
    Views
    1,089

    To put this in perspective, the service person...

    To put this in perspective, the service person found a failed combustion motor and possible unreliable control board and did the right thing in suggesting replacement. The next step which he wouldn't...
  27. Do you have outside air ducted to the furnace's...

    Do you have outside air ducted to the furnace's return air for ventilation? If so an automatic damper should be installed. Are you running some sort of exhaust when this happens? Typically warm air...
  28. Replies
    10
    Views
    554

    Please put hans back in pockets it's -7F...

    Please put hans back in pockets it's -7F here.:grin2:
  29. Replies
    10
    Views
    554

    What is the little green box for

    What is the little green box for when hovered over say,"Standing around truck with hands in pockets" or something to that effect. I don't ever remember seeing that before
  30. Replies
    6
    Views
    339

    Just one more thing to add to HVAC69's excellent...

    Just one more thing to add to HVAC69's excellent explanation, if this is controlled by a DDC controller or any controller for that matter two binary outputs are needed. One for open and one for close.
  31. Replies
    8
    Views
    502

    any change of a diagram. Are you running a...

    any change of a diagram. Are you running a primary loop from boiler to tank and back and another loop to zone?
  32. Replies
    11
    Views
    945

    I recently ended up replacing a speed control and...

    I recently ended up replacing a speed control and combustion motor for th same reason. Combustion fan was running to slow. Also had terrible smelling flue gasses. Obviously check heat exchanger...
  33. Fuses protect the conductors. wires are sized per...

    Fuses protect the conductors. wires are sized per amperage and fuses stop current if value is exceeded. Fuses aren't always used to protect a device. Some smaller control fuses do protect an...
  34. Replies
    6
    Views
    435

    Cheap way, Supply 55f to 65f from RTU based on...

    Cheap way, Supply 55f to 65f from RTU based on OA temp and provide electric zone reheat for each zone. Reheats are duct mounted. Can be modulating. I don't think VVT will work well with that many...
  35. Replies
    50
    Views
    2,972

    Whether the trans has a grounded secondary or not...

    Whether the trans has a grounded secondary or not you should still see 24 vac across the secondary. Or read from R to C on the terminal strip.
  36. Replies
    31
    Views
    1,516

    That makes no sense. Sequencers fail and can be...

    That makes no sense. Sequencers fail and can be replaced. Many companies work on electric heat. If the equipment has been drastically redesigned then maybe no one wants the responsibility.
  37. Replies
    17
    Views
    1,007

    I have seen similar480v 3 phase heater package on...

    I have seen similar480v 3 phase heater package on a singe phase 230 v carrier resi ahu. They sold a single point power package which contained a 480 to 240 transformer to power the furnace fan and...
  38. Replies
    10
    Views
    703

    What is the humidity in the space? What is the...

    What is the humidity in the space? What is the cold surface temperature? Indoor dewpoint must be above cold surface temperature or condensation will result. What is the source of humidity?
  39. It's interesting that you did that. Many of use...

    It's interesting that you did that. Many of use don't time, time delays that are working. Maybe there is a component failing on the control board but it is not something that at a technician level we...
  40. Thread: help?

    by ckartson
    Replies
    19
    Views
    965

    My point exactly, Thanks for saying it clearly.

    My point exactly, Thanks for saying it clearly.
  41. Thread: help?

    by ckartson
    Replies
    19
    Views
    965

    What parts are you missing? you should need...

    What parts are you missing? you should need control wire, power wire, acr pipe, armaflex insulation, special Y fittings.
  42. I looked up the wiring diagram for your furnace...

    I looked up the wiring diagram for your furnace and see the note 7 that you are referring to. The jumper will allow the fan to run at a higher speed when the stat is set to fan on. Depending on duct...
  43. You stated you have no ac. Don't connect the...

    You stated you have no ac. Don't connect the jumper. Connecting the jumper G term= fan, Y/Y2=cool stage 1 or cool stage 2 will energize fan on a call for cooling or energize cooling when tstat is set...
  44. Thread: Cooling Off

    by ckartson
    Replies
    60
    Views
    4,683

    Wha tev?

    Wha tev?
  45. Replies
    27
    Views
    1,784

    Either should close quickly. Freeze stats should...

    Either should close quickly. Freeze stats should be hard wired to provide immediate closure to power to damper actuator or to ep for pneumatic actuator. Not closing completely is a problem with both...
  46. Thread: Torpedo level

    by ckartson
    Replies
    9
    Views
    650

    Try goggling "bubble" from your phone. Its pretty...

    Try goggling "bubble" from your phone. Its pretty cool. Ok for a quick small level if it fits. Wouldn't pipe up a hole building with it.
  47. Replies
    16
    Views
    1,062

    I use a tree with the two valves on it. After I...

    I use a tree with the two valves on it. After I am assured of proper micron level I valve off both valves of my tree. I install my manifold to the center isolated port of my tree. Attach yellow...
  48. Replies
    57
    Views
    5,242

    Condensor is to clean.

    Condensor is to clean.
  49. Replies
    64
    Views
    2,788

    Many guys may be sucked in by that "trick...

    Many guys may be sucked in by that "trick question" but if the same guys walked on a job and saw a flue connected to an electric furnace they would probably not be tricked. It would be posted in the...
  50. Replies
    9
    Views
    1,158

    Check or replace all electrical connections,...

    Check or replace all electrical connections, dirty or poor connections on a MV system will cause this. Test the valve with a flashlight battery.