  1. Replies
    6
    Views
    217

    With Honeywell Redlink, you can put the actual...

    With Honeywell Redlink, you can put the actual switching module in the furnace room and the wall thermostat anywhere in the house and they talk wirelessly on a private frequency. You would need one...
  2. Then there was the unit we were removing. It did...

    Then there was the unit we were removing. It did have valves but they weren't closed. One guy inside a short fence handed me the unit on a fence post, before my helper and I could grab it, some...
  3. Replies
    16
    Views
    342

    There may be a few matches that do, usually small...

    There may be a few matches that do, usually small sizes. What size do you need?
  4. Use a TAM7 air handler and a thermostat with...

    Use a TAM7 air handler and a thermostat with dehumidifiy on demand capability, nice combo.
  5. Replies
    5
    Views
    167

    Most brands have a 17.5" 3 ton. Rheem does, match...

    Most brands have a 17.5" 3 ton. Rheem does, match it with the RANL-JAZ outdoor unit and you get your pressure protection.
  6. Dang, forgot all about Amana. My memory is ...

    Dang, forgot all about Amana. My memory is starting to go :(

    Looks like ThermoPride still is in their 95%. Their 80s are, gasp, Yorkies. Looks like they have a York 95% for those "budget minded".
  7. Replies
    17
    Views
    402

    Seen way too many of these, namely with Rheem...

    Seen way too many of these, namely with Rheem heat pumps as Rheem didn't believe in loss of charge switches in 10 SEER. And then all this work is going to make a horribly mismatched system try to...
  8. Quiets things down, lessens the shock on the...

    Quiets things down, lessens the shock on the reversing valve. With the higher pressures of 410 and the large quantities of refrigerant in today's high SEER units, it helps more than the strain. Mine...
  9. Replies
    17
    Views
    402

    Green slime. Comes from running the unit empty...

    Green slime. Comes from running the unit empty and sucking moisture into the oil. It's gonna haunt you and require lots of cleaning. May never get rid of it. Plan on a short life.

    The 5 ton coil...
  10. 800 sq ft in the SE if you tighten it up sounds...

    800 sq ft in the SE if you tighten it up sounds like a 1.5 ton HP and a 7kw heat strip.

    I suppose 2 stage 2 ton would work as well. 40K 95% furnace is way too big. I had my 2 stage 95% on low...
  11. Those aren't links, that's the AHRI rating of...

    Those aren't links, that's the AHRI rating of each outdoor unit. The XR15 has 1 point more SEER, .5 point more EER and HSPF so you are getting a slightly more efficient system. If there is a...
  12. I guess I'd have to agree & disagree with Chuck...

    I guess I'd have to agree & disagree with Chuck on this.

    Our customers love 2 stage furnace. We always put them on 2 stage stats. They run on gentle, quiet low most of the time, which is not...
  13. That blower is likely 2 ton on low so you'd...

    That blower is likely 2 ton on low so you'd likely have to run the same speed for high & low if you get a 2 ton 2 stage. Then you won't dehumidfy real well on low stage moving too much air.

    Still...
  14. Unless the ceramic is cracked, the flame rod...

    Unless the ceramic is cracked, the flame rod should be fine. I doubt you have a board issue. Still suggest he focus on the pressure switch causing it. I spent a morning on a Trane 90 once, finally...
  15. You'd be far shy of the SEER that A/C is capable...

    You'd be far shy of the SEER that A/C is capable of with the standard motor so you'd be paying hundreds or more to save peanuts. It can be done, gotta jury rig blower speeds to get close to the CFM...
  16. I don't know that Carrier ever used stainless...

    I don't know that Carrier ever used stainless primary. ICP did for a while on high end 90s. The RPJ was a tradename ICP got from Snyder, didn't mean it was stainless. I looked at ICPs furnace and...
  17. Replies
    8
    Views
    372

    BTUs are BTUs. I went from a 2 ton R22 to a 2 ton...

    BTUs are BTUs. I went from a 2 ton R22 to a 2 ton R410a and feel the house cools better now. Of course just cuz they say 2 ton doesn't mean they are 24,000 BTUs.

    Most duct systems are margainly...
  18. Last time I heard that it was a sag in the flue...

    Last time I heard that it was a sag in the flue in the attic.

    Why is the flex gas line run into the furnace cabinet?
  19. The XR13 gets 15.00 SEER, 12.50 EER and 9 HSPF ...

    The XR13 gets 15.00 SEER, 12.50 EER and 9 HSPF

    The XR14 gets 14.50 SEER, 12.00 EER and 8.5 HSPF

    So they aren't doing you any favors with the XR14 over the XR13 you were suposed to get :(
  20. No manual J needed is first red flag. I'm with...

    No manual J needed is first red flag. I'm with pecmsg, 2 tons sounds way too high. Friend had a 2 story 800 sq ft per floor with foam, lots of windows. 2 ton did great in an area sized to 95 out....
  21. Replies
    5
    Views
    216

    Microchannel outdoor coil? Toward the end of the...

    Microchannel outdoor coil? Toward the end of the defrost, the hot gas valve opens and they dump more at the bottom of the coil to be sure it is fully defrosted. Many brands had problems in the past...
  22. A Willie Gasaver is just getting broken in at 31...

    A Willie Gasaver is just getting broken in at 31 years old :D but it is far from a Gas Saver and there are some obsolete parts & controls! Need to find an old timer that has seen a White-Rogers...
  23. Is that on the air handler?

    Is that on the air handler?
  24. Gas packs usually have their HX in the cold air...

    Gas packs usually have their HX in the cold air stream which ruins them rather quickly. I've seen many not get 10 years. So look over that heat exchanger very carefully before going to the expense of...
  25. Trane uses Danfoss compressors. Carrier uses...

    Trane uses Danfoss compressors. Carrier uses Copeland in the variable speed. Toshiba rotaries in the 5 step.

    I've only heard one and that was in a classroom, very quiet.
  26. I just glanced at the manual for the air handler....

    I just glanced at the manual for the air handler. It does not address adding a humidifier at all. Wonder how he wired it. The blower activation of the 700 automatic probably won't work with the...
  27. Is it set to shut off the heat pump below a...

    Is it set to shut off the heat pump below a certain outdoor temp? If you are on heat pump below a certain point, I'm set to 25 as I keep the house cold, the heat pump will run constantly and you'll...
  28. The Econet won't work with today's air handlers....

    The Econet won't work with today's air handlers. For 2015 there's a new line coming out. So far haven't seen anything on the communicating models though. The translator lets you use the JEC heat...
  29. Replies
    3
    Views
    195

    It's whatever that manufacturer called for....

    It's whatever that manufacturer called for. Sometimes they oversized the air handler for efficiency. The blower needed to be set for 800 CFM though, I bet that didn't happen!
  30. Can't use a bypass? Powered on the return don't...

    Can't use a bypass? Powered on the return don't do a whole lot. Certainly should be on hot water.

    How much room around the unit? A sharp installer can mount a bypass on a metal box and make it...
  31. I don't its that unusual, especially the inside...

    I don't its that unusual, especially the inside picture.
  32. Given the reliability of pressure switches today,...

    Given the reliability of pressure switches today, I'd more bet that the switch did stick and the board is fine.

    How old? Is there any warranty?
  33. Replies
    1
    Views
    145

    Though we can't discussing pricing, since I saw...

    Though we can't discussing pricing, since I saw it I'd say call another dealer!

    If you are guying a 16 SEER A/C, if you really want near 16 SEER, you need the XT or XV. With the standard motor of...
  34. Replies
    5
    Views
    343

    We haven't had any either, lots of Choo Choos in...

    We haven't had any either, lots of Choo Choos in our area plus all the American Standards we sold.
  35. Thread: Trane Coil

    by BaldLoonie
    Replies
    2
    Views
    206

    40 sounds like Trane talk for 4 ton I would think.

    40 sounds like Trane talk for 4 ton I would think.
  36. Replies
    8
    Views
    302

    May be able to rent an ozone generator for a few...

    May be able to rent an ozone generator for a few days. Home should be unoccupied.
  37. Replies
    11
    Views
    348

    The 104 is now the 145 if I recall right, the 80V...

    The 104 is now the 145 if I recall right, the 80V for the Intell boards.

    Isn't the A0 model using the 00054?

    None of them have a metal shield around them, that sounds like one that Allied...
  38. Replies
    8
    Views
    302

    I put a UV light with 40% ozone generation in a...

    I put a UV light with 40% ozone generation in a large house for a friend whose m-i-l smoked up a storm in there. A few days later smell was gone. So certainly something worth trying.
  39. Replies
    29
    Views
    1,195

    Some of the Venstar models (aka Totaline) don't...

    Some of the Venstar models (aka Totaline) don't click, they use a triac instead of relay.
  40. With B-vent, every brand fits differently. The...

    With B-vent, every brand fits differently. The right way is look for the cap from the manufacturer of the pipe. Look on a section for a brand name then have your heating contractor get you a cap from...
  41. Replies
    4
    Views
    155

    If you have a limited budget, why not a 95% gas...

    If you have a limited budget, why not a 95% gas furnace? A fraction of the cost of a condensing boiler and hot water fan coil.
  42. Replies
    4
    Views
    216

    A blanket on a scroll makes little difference....

    A blanket on a scroll makes little difference. What may be a big difference in sound between the XB and XR is the use of a swept wing fan blade on the XR.

    They both use the same compressor. The...
  43. Replies
    6
    Views
    186

    When it goes into defrost, usually you'll see a...

    When it goes into defrost, usually you'll see a little steam come off the outdoor unit and lots of water dripping out the bottom of it.
  44. Replies
    17
    Views
    674

    It may be on low and use less electricity but it...

    It may be on low and use less electricity but it is removing the same amount of heat so the extra run time would mean essentially electrical use as if it ran on high only. He has a very healthy...
  45. Replies
    3
    Views
    183

    http://www.magicpak.com/products/ I don't...

    http://www.magicpak.com/products/

    I don't think any of these were meant to be ducted though. If the Friedrich was, not sure what you can do.
  46. Replies
    16
    Views
    450

    We did a charity job in the ghetto recently. They...

    We did a charity job in the ghetto recently. They had a downflow in the basement obviously taking out a lowboy in the past. It sat on a return box. So it was blowing down into a box then the air had...
  47. Replies
    17
    Views
    674

    In the OP's quote, it is between 14.5 and 16 SEER...

    In the OP's quote, it is between 14.5 and 16 SEER and 1 EER point less. I can't imagine a real big savings. Being Phoenix, both options were for 80% furnaces so no gas savings with the higher bid....
  48. Replies
    6
    Views
    186

    In defrost?

    In defrost?
  49. Replies
    17
    Views
    674

    Quote 1 gets 14.50 SEER, you can improve that to...

    Quote 1 gets 14.50 SEER, you can improve that to 15.75 SEER with a 4NCXD063 coil. That wouldn't cost too much more.

    Quote 2 does hit 16.00 SEER. Bigger furnace but 2 stage and variable speed...
  50. Replies
    47
    Views
    1,459

    I loved the multiflex coils. What other coil...

    I loved the multiflex coils. What other coil could give you a .15" static drop at 1200 on a 17" 3 ton coil? The N coil is about .4" in the same size.

    The multiflex never leaked expect in...
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event