Search:
Type: Posts; User: phxhvac
Search: Search took 0.01 seconds.
-
05-16-2013, 08:41 PM
- Replies
- 22
- Views
- 589
When I did markets. All of the service managers...
When I did markets. All of the service managers were on their third marriage. It is good money if you can stand the hours.
Sent from my DROID RAZR using Tapatalk 2 -
05-05-2013, 11:51 AM
- Replies
- 45
- Views
- 1,264
Terminal venting flash fires, no recovery...
Terminal venting flash fires, no recovery equipment yet, having to move the equipment outdoors to work on it. Not to mention what it is going to do to a companies liability insurance. I have a...
-
05-04-2013, 08:15 PM
- Replies
- 45
- Views
- 1,264
True Manufacturing Going To R-290 (Propane)
Just received the study guide from the boss. True Manufacturing is coming out with some new R-290 units soon. The certification test is in a week!
Sent from my DROID RAZR using Tapatalk 2 -
05-01-2013, 03:32 PM
Thread: Best Replacement Ice Machine
by phxhvac- Replies
- 31
- Views
- 824
Hoshizaki is the way to go! Sent from my...
Hoshizaki is the way to go!
Sent from my DROID RAZR using Tapatalk 2 -
04-27-2013, 03:32 PM
Thread: ice machine cleaner
by phxhvac- Replies
- 34
- Views
- 865
On those Manitowoc probes. It is better to just...
On those Manitowoc probes. It is better to just replace them if they are bad enough. I've had few of them go bad after trying to clean them.
Sent from my DROID RAZR using Tapatalk 2 -
04-27-2013, 03:19 PM
Thread: ice machine cleaner
by phxhvac- Replies
- 34
- Views
- 865
Agreed, not on the water circuit, or ice...
Agreed, not on the water circuit, or ice production areas. Lime solvent just on the white flaky stuff on the exterior of the machine if they are concerned with cosmetics. Never on the water circuit...
-
04-26-2013, 11:51 PM
Thread: ice machine cleaner
by phxhvac- Replies
- 34
- Views
- 865
I meant to say clean the non ice and water areas...
I meant to say clean the non ice and water areas with the lime solvent. And nickel safe for the ice production areas.
Sent from my DROID RAZR using Tapatalk 2 -
04-26-2013, 08:43 PM
Thread: ice machine cleaner
by phxhvac- Replies
- 34
- Views
- 865
And lime solvent for the compressor area where...
And lime solvent for the compressor area where that white crud forms. Oh and a gasket scraper when it softens up.
Sent from my DROID RAZR using Tapatalk 2 -
04-26-2013, 08:39 PM
Thread: ice machine cleaner
by phxhvac- Replies
- 34
- Views
- 865
What about nickel safe ice machine cleaner? ...
What about nickel safe ice machine cleaner?
Sent from my DROID RAZR using Tapatalk 2 -
04-23-2013, 10:32 PM
Thread: reach in freezer
by phxhvac- Replies
- 18
- Views
- 663
What is your superheat? Sent from my DROID...
What is your superheat?
Sent from my DROID RAZR using Tapatalk 2 -
Does anybody still have plating on the...
Does anybody still have plating on the evaporators of these CME machines. It seems like every one I go up to had the plating coming off or completely gone.
Sent from my DROID RAZR using Tapatalk 2 -
04-19-2013, 09:54 PM
Thread: Nitrogen or No Nitrogen?
by phxhvac- Replies
- 73
- Views
- 2,708
Always use nitrogen to purge if possible. Do it...
Always use nitrogen to purge if possible. Do it right... do it once.
Sent from my DROID RAZR using Tapatalk 2 -
04-18-2013, 10:23 PM
Thread: Best Reach In Refrigerator/Freezer
by phxhvac- Replies
- 28
- Views
- 1,037
Continentals are good! They are easy to service....
Continentals are good! They are easy to service.
Sent from my DROID RAZR using Tapatalk 2 -
03-30-2013, 05:25 PM
Thread: Did I over price
by phxhvac- Replies
- 23
- Views
- 990
Good post! Sent from my DROID RAZR using...
Good post!
Sent from my DROID RAZR using Tapatalk 2 -
03-22-2013, 11:52 PM
Thread: uv leak dye
by phxhvac- Replies
- 24
- Views
- 1,118
Me too! Sent from my DROID RAZR using Tapatalk...
Me too!
Sent from my DROID RAZR using Tapatalk 2 -
03-22-2013, 11:41 PM
Thread: REVIEW: Nylog Gasket and Thread Sealant
by phxhvac- Replies
- 44
- Views
- 1,833
Cool thx! Sent from my DROID RAZR using...
Cool thx!
Sent from my DROID RAZR using Tapatalk 2 -
03-22-2013, 11:17 PM
Thread: REVIEW: Nylog Gasket and Thread Sealant
by phxhvac- Replies
- 44
- Views
- 1,833
Do you apply it to the threads of the fitting or...
Do you apply it to the threads of the fitting or the back of the flare? Just curious. I have been using it on the threads.
Sent from my DROID RAZR using Tapatalk 2 -
03-11-2013, 11:08 PM
Thread: uv leak dye
by phxhvac- Replies
- 24
- Views
- 1,118
Agreed, the H-10 is the way to go! Sent from...
Agreed, the H-10 is the way to go!
Sent from my DROID RAZR using Tapatalk 2 -
03-11-2013, 12:29 AM
Thread: uv leak dye
by phxhvac- Replies
- 24
- Views
- 1,118
It also voids the warranty on equipment if it is...
It also voids the warranty on equipment if it is used. It displaces what the filter drier catches and blows it out the back of the drier. Plus it makes a mess of your gauges.
Sent from my DROID... -
02-26-2013, 09:06 AM
Thread: Superheat Cap Tube Systems
by phxhvac- Replies
- 4
- Views
- 356
What kind of superheat should you expect when the...
What kind of superheat should you expect when the cap tube system is operating properly? 15-30 degrees?
Sent from my DROID RAZR using Tapatalk 2 -
02-26-2013, 12:19 AM
Thread: Superheat Cap Tube Systems
by phxhvac- Replies
- 4
- Views
- 356
Superheat Cap Tube Systems
When taking superheat on a cap tube system, reach-in, or prep table with a cap tube. Where is the proper place to measure suction line temperature. I have seen guys measure it 3 inches away from the...
-
02-24-2013, 11:23 PM
Thread: whats yall vacuum pump preference??
by phxhvac- Replies
- 75
- Views
- 3,179
JB the heavy 6 CFM one. Sent from my DROID...
JB the heavy 6 CFM one.
Sent from my DROID RAZR using Tapatalk 2 -
02-24-2013, 11:22 PM
Thread: Best Set of Allen/Hex Keys
by phxhvac- Replies
- 9
- Views
- 410
Allen makes a good set. Try them! Sent from my...
Allen makes a good set. Try them!
Sent from my DROID RAZR using Tapatalk 2 -
Heat Guns
I am looking at buying a quality heat gun for refrigeration work mostly reach-ins and walk-ins. What temperature range should I get? Any thoughts?
Sent from my DROID RAZR using Tapatalk 2 -
Fluke 336 Clamp Fluke 179 Multi Fluke 54 II...
Fluke 336 Clamp
Fluke 179 Multi
Fluke 54 II Temp
Sent from my DROID RAZR using Tapatalk 2
Results 1 to 25 of 202

