  1. Thread: MO99 Retro

    by Gibbo
    Replies
    10
    Views
    770

    Curious as to why Carrier Service US would advise...

    Curious as to why Carrier Service US would advise retrofiting a chiller over selling a new chiller it doesn't make sense as here in the UK Dupont drop ins are given a wide berth due to various...
  2. Replies
    7
    Views
    882

    This is the Ask Our Pro's forum. In order to post...

    This is the Ask Our Pro's forum. In order to post a response here, you must have verified qualifications and have been approved by the AOP Committee. You may ask a question by starting a new thread....
  3. Replies
    2
    Views
    631

    There was a big problem with refrigerated sea...

    There was a big problem with refrigerated sea containers blowing up in Vietnam some months ago due to this problem. I think it resulted in some deaths and large amounts of sea containers having to be...
  4. Replies
    21
    Views
    1,638

    I think you will find that PTFE tape exposed to...

    I think you will find that PTFE tape exposed to refrigerant blends and polyester oil will start to leak eventually hence the loctite or other suitable thread sealant.
  5. Replies
    21
    Views
    1,638

    We use Loctite 577 here in the UK, If your Leak...

    We use Loctite 577 here in the UK, If your Leak Lock is in blue coloured tubes i have used it as well but i prefer Loctite 577 but you need to ensure the connections are dry and clean to start with....
  6. In that case it might be as cheap to replace the...

    In that case it might be as cheap to replace the chiller if glycol is inside it now. Good luck whatever you do. You will find it a useful learning curve. I know of many techs with many years of...
  7. First of all we are talking water contamination...

    First of all we are talking water contamination here not moisture so all of the refrigerant and oil needs to be removed and disposed off, remember water can get trapped under the oil which will...
  8. Replies
    11
    Views
    1,713

    HI There Cowboy Hope your well and life is good ...

    HI There Cowboy Hope your well and life is good

    Yes its a pro dialog
  9. Replies
    11
    Views
    1,713

    As this is quite a small chiller i suspect its...

    As this is quite a small chiller i suspect its controlling on return water and not leaving water as with the larger models.
    Part number will be on the cable of the sensor
  10. Sounds like the Air Conditioning is being shut...

    Sounds like the Air Conditioning is being shut down late in the evening. If this is a chilled water system then it seems strange that the building temp feels ok but your office is very warm.
    You...
  11. Replies
    51
    Views
    4,875

    You need to take a step back and think about...

    You need to take a step back and think about this.
    UNDER NO CIRCUMSTANCES START THIS UNIT UP WITH R410A.
    None of the components will be rated for R410A and are likely to fail using R410A.
    If you...
  12. Thread: Old chiller.

    by Gibbo
    Replies
    14
    Views
    954

    At 21 years old i would be looking to replace it...

    At 21 years old i would be looking to replace it not change out cooler and other parts.
  13. Replies
    23
    Views
    2,632

    Your not having much luck on Transocean Rig 135...

    Your not having much luck on Transocean Rig 135 are you.
  14. Replies
    23
    Views
    2,632

    Not on a oil rig of the west coast of Africa

    Not on a oil rig of the west coast of Africa
  15. Replies
    23
    Views
    2,632

    Your main problem is that you will have up to 50%...

    Your main problem is that you will have up to 50% of the oil mixed with the refrigerant, so if you only drain the oil from the condenser then you will only get a few litres of oil at most which is...
  16. Replies
    23
    Views
    2,632

    Yes you have a phase 3 pro dialog. Which oil...

    Yes you have a phase 3 pro dialog.
    Which oil filter are you changing internal external or both.
    If you are experiencing multiple oil filter failure problems you may need to change the oil as well....
  17. Replies
    23
    Views
    2,632

    There are 2 versions of 30hxc pro dialog if built...

    There are 2 versions of 30hxc pro dialog if built prior to 2001 its phase 2 if after its phase 3. try this web site.

    http://eto.carrier.com/lit.asap

    scroll down product page until you reach...
  18. Replies
    12
    Views
    891

    Can't imagine where you got the idea you could...

    Can't imagine where you got the idea you could claim for warranty labour don't know any manufacturer in any field anywhere on this planet allowing non company labour to carry out repairs to their...
  19. Replies
    8
    Views
    1,320

    Here is Carriers O6C/D/E/ Service Guide Book,...

    Here is Carriers O6C/D/E/ Service Guide Book, start up is near the back
  20. Replies
    5
    Views
    387

    Most likely the oil is mixed with the refrigerant...

    Most likely the oil is mixed with the refrigerant in the cooler / condenser unless of course their are large amounts of oil around the chiller to tell you otherwise.

    Gibbo

    :cheers:
  21. Replies
    8
    Views
    606

    The answer is still no with the current control...

    The answer is still no with the current control system.
    It is only 1 chiller with 1 cooler using Pro Dialog Control (French built).
  22. Replies
    8
    Views
    606

    The answer is no why would you want to split the...

    The answer is no why would you want to split the chiller into 2.

    Gibbo
  23. Replies
    33
    Views
    3,667

    If you look at the 2nd last photograph there is...

    If you look at the 2nd last photograph there is clearly some sort of enclosure behind the fan cowlings.
  24. Replies
    13
    Views
    9,193

    Go to Carrier European Product Website. ...

    Go to Carrier European Product Website.

    http://eto.carrier.com/lit.asp

    search under products for your model number and hit search button, all available information will then be shown.

    What...
  25. Replies
    33
    Views
    3,667

    It looks as if the fan motor may be twisting...

    It looks as if the fan motor may be twisting trying to overcome static pressure. The photo showing the fan sections is that some sort of enclosure around the top of the unit.
Results 1 to 25 of 157