Curious as to why Carrier Service US would advise...
Curious as to why Carrier Service US would advise retrofiting a chiller over selling a new chiller it doesn't make sense as here in the UK Dupont drop ins are given a wide berth due to various...
-
11-13-2012, 01:24 PM
Thread: split chiller tubes
by Gibbo- Replies
- 7
- Views
- 882
This is the Ask Our Pro's forum. In order to post...
This is the Ask Our Pro's forum. In order to post a response here, you must have verified qualifications and have been approved by the AOP Committee. You may ask a question by starting a new thread....
-
05-17-2012, 02:32 PM
Thread: A warning about some R-134a
by Gibbo- Replies
- 2
- Views
- 631
There was a big problem with refrigerated sea...
There was a big problem with refrigerated sea containers blowing up in Vietnam some months ago due to this problem. I think it resulted in some deaths and large amounts of sea containers having to be...
-
01-07-2012, 12:47 PM
Thread: Not able to seal systems with POE Oils
by Gibbo- Replies
- 21
- Views
- 1,638
I think you will find that PTFE tape exposed to...
I think you will find that PTFE tape exposed to refrigerant blends and polyester oil will start to leak eventually hence the loctite or other suitable thread sealant.
-
01-06-2012, 01:41 PM
Thread: Not able to seal systems with POE Oils
by Gibbo- Replies
- 21
- Views
- 1,638
We use Loctite 577 here in the UK, If your Leak...
We use Loctite 577 here in the UK, If your Leak Lock is in blue coloured tubes i have used it as well but i prefer Loctite 577 but you need to ensure the connections are dry and clean to start with....
-
01-06-2012, 01:29 PM
- Replies
- 31
- Views
- 2,084
In that case it might be as cheap to replace the...
In that case it might be as cheap to replace the chiller if glycol is inside it now. Good luck whatever you do. You will find it a useful learning curve. I know of many techs with many years of...
-
01-05-2012, 02:54 PM
- Replies
- 31
- Views
- 2,084
First of all we are talking water contamination...
First of all we are talking water contamination here not moisture so all of the refrigerant and oil needs to be removed and disposed off, remember water can get trapped under the oil which will...
-
08-13-2011, 04:36 AM
Thread: Carrier 30RA Thermistor
by Gibbo- Replies
- 11
- Views
- 1,713
HI There Cowboy Hope your well and life is good ...
HI There Cowboy Hope your well and life is good
Yes its a pro dialog -
08-12-2011, 06:57 PM
Thread: Carrier 30RA Thermistor
by Gibbo- Replies
- 11
- Views
- 1,713
As this is quite a small chiller i suspect its...
As this is quite a small chiller i suspect its controlling on return water and not leaving water as with the larger models.
Part number will be on the cable of the sensor -
07-28-2011, 04:52 AM
- Replies
- 5
- Views
- 674
Sounds like the Air Conditioning is being shut...
Sounds like the Air Conditioning is being shut down late in the evening. If this is a chilled water system then it seems strange that the building temp feels ok but your office is very warm.
You... -
07-09-2011, 04:25 AM
Thread: 30 ton split R-22 to 410a
by Gibbo- Replies
- 51
- Views
- 4,875
You need to take a step back and think about...
You need to take a step back and think about this.
UNDER NO CIRCUMSTANCES START THIS UNIT UP WITH R410A.
None of the components will be rated for R410A and are likely to fail using R410A.
If you... -
04-01-2011, 03:07 PM
Thread: Old chiller.
by Gibbo- Replies
- 14
- Views
- 954
At 21 years old i would be looking to replace it...
At 21 years old i would be looking to replace it not change out cooler and other parts.
-
10-28-2010, 04:40 PM
Thread: Carrier 30HXC screw with pro dialog
by Gibbo- Replies
- 23
- Views
- 2,632
Your not having much luck on Transocean Rig 135...
Your not having much luck on Transocean Rig 135 are you.
-
10-27-2010, 04:46 PM
Thread: Carrier 30HXC screw with pro dialog
by Gibbo- Replies
- 23
- Views
- 2,632
Not on a oil rig of the west coast of Africa
Not on a oil rig of the west coast of Africa
-
10-27-2010, 04:03 PM
Thread: Carrier 30HXC screw with pro dialog
by Gibbo- Replies
- 23
- Views
- 2,632
Your main problem is that you will have up to 50%...
Your main problem is that you will have up to 50% of the oil mixed with the refrigerant, so if you only drain the oil from the condenser then you will only get a few litres of oil at most which is...
-
10-27-2010, 03:37 PM
Thread: Carrier 30HXC screw with pro dialog
by Gibbo- Replies
- 23
- Views
- 2,632
Yes you have a phase 3 pro dialog. Which oil...
Yes you have a phase 3 pro dialog.
Which oil filter are you changing internal external or both.
If you are experiencing multiple oil filter failure problems you may need to change the oil as well.... -
10-27-2010, 02:24 PM
Thread: Carrier 30HXC screw with pro dialog
by Gibbo- Replies
- 23
- Views
- 2,632
There are 2 versions of 30hxc pro dialog if built...
There are 2 versions of 30hxc pro dialog if built prior to 2001 its phase 2 if after its phase 3. try this web site.
http://eto.carrier.com/lit.asap
scroll down product page until you reach... -
10-02-2010, 01:31 PM
Thread: Carrier Ext Warr Labor
by Gibbo- Replies
- 12
- Views
- 891
Can't imagine where you got the idea you could...
Can't imagine where you got the idea you could claim for warranty labour don't know any manufacturer in any field anywhere on this planet allowing non company labour to carry out repairs to their...
-
08-29-2010, 03:43 PM
Thread: CARRIER/CARLYLE COMPRESSOR STSRTUP SHEET
by Gibbo- Replies
- 8
- Views
- 1,320
Here is Carriers O6C/D/E/ Service Guide Book,...
Here is Carriers O6C/D/E/ Service Guide Book, start up is near the back
-
08-20-2010, 03:38 PM
Thread: oil change on 30gxn225
by Gibbo- Replies
- 5
- Views
- 387
Most likely the oil is mixed with the refrigerant...
Most likely the oil is mixed with the refrigerant in the cooler / condenser unless of course their are large amounts of oil around the chiller to tell you otherwise.
Gibbo
:cheers: -
07-31-2010, 03:50 AM
Thread: Carrier 30GH245 splitting
by Gibbo- Replies
- 8
- Views
- 606
The answer is still no with the current control...
The answer is still no with the current control system.
It is only 1 chiller with 1 cooler using Pro Dialog Control (French built). -
07-30-2010, 06:42 PM
Thread: Carrier 30GH245 splitting
by Gibbo- Replies
- 8
- Views
- 606
The answer is no why would you want to split the...
The answer is no why would you want to split the chiller into 2.
Gibbo -
03-21-2010, 02:08 PM
Thread: Carrier 30XA Air Cooled Screw Chiller WTF!
by Gibbo- Replies
- 33
- Views
- 3,667
If you look at the 2nd last photograph there is...
If you look at the 2nd last photograph there is clearly some sort of enclosure behind the fan cowlings.
-
03-21-2010, 01:46 PM
Thread: Carrier's Pro Dialog Plus User Guide
by Gibbo- Replies
- 13
- Views
- 9,193
Go to Carrier European Product Website. ...
Go to Carrier European Product Website.
http://eto.carrier.com/lit.asp
search under products for your model number and hit search button, all available information will then be shown.
What... -
03-20-2010, 05:24 PM
Thread: Carrier 30XA Air Cooled Screw Chiller WTF!
by Gibbo- Replies
- 33
- Views
- 3,667
It looks as if the fan motor may be twisting...
It looks as if the fan motor may be twisting trying to overcome static pressure. The photo showing the fan sections is that some sort of enclosure around the top of the unit.
Results 1 to 25 of 157