Search:

Type: Posts; User: coolerinfrederick

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. Exactly, im going back to the pneumatic stat and...

    Exactly, im going back to the pneumatic stat and kele makes a transducer that will work , gets a lil tricky cause I actually will need 2 transducers and they will need to calibrate to a specific...
  2. What about the cooling , and it might be too...

    What about the cooling , and it might be too difficult to pull a cable 4 floors
  3. Except the old one was pneumatic

    Except the old one was pneumatic
  4. Yeah , basically there was a stat on a floor for...

    Yeah , basically there was a stat on a floor for space temp control. It went to an old pneumatic step controller for the electric heat and to 2 pe switches. We replaced the heater and it needed a...
  5. outside ahu control with dx split coil ?

    Whats the best way to control mechanical cooling off of discharge air ?
  6. Replies
    43
    Views
    1,733

    50 k a yr is not alot of money nowadays, I shoot...

    50 k a yr is not alot of money nowadays, I shoot for double that
  7. Replies
    1
    Views
    186

    I had one tripping on low o2 too, engineer got...

    I had one tripping on low o2 too, engineer got the manufracturer to come out and they said it was the regulator , not sure if it fixed though , didnt make much sense to me , not my problem anymore...
  8. Replies
    55
    Views
    2,802

    http://ladderbuggy.com/features/

    http://ladderbuggy.com/features/
  9. Replies
    55
    Views
    2,802

    http://www.troweltrades.net/product_info.php?cPath...

    http://www.troweltrades.net/product_info.php?cPath=43_92&products_id=8009
  10. Replies
    55
    Views
    2,802

    i saw this thing you attach to your ext. ladder...

    i saw this thing you attach to your ext. ladder and winch it up
  11. 2 carrier 38AH 054 condensers losing mulitpe (06e) compressors ?

    so here is what we know: . single circuit and no branch off to solenoid valves for staging and only one txv on the evaporator coil. Also No oil trap at the ahu on suction line . Unit has 2) 25 ton...
  12. 40 ton txv on a 20 ton compressor ?

    Well not really , bad install . No LL solenoid valves and one txv on coil. Also No oil trap at the ahu on suction line . Unit has 2 20 ton carlyles . Also they ahu is 100% oa . Take a guess what...
  13. Replies
    1
    Views
    255

    Old Westinghouse

    I've got an old water cooled unit
    M# SH0551V
    Item# 761D034G11
    S# BX8526
    It's got a decent size semi recip. Sitting on top of the barrel that I'm trying to get manuals on , sorry didn't write...
  14. Replies
    10
    Views
    1,004

    cool pics, i've never seen the inside of one. if...

    cool pics, i've never seen the inside of one. if i suspect issues with a gearbox we bring in a company that specializes in tower work. is this a repair you guys do all the time ?
  15. Replies
    10
    Views
    604

    thanks ken

    thanks ken
  16. Replies
    10
    Views
    604

    i do it all really, but i'm willing to do...

    i do it all really, but i'm willing to do whatever the bossman tells me. here's part of my resume
    Qualifications

    Over 12 years in the trade, ranging in repair, installation, preventive...
  17. Replies
    10
    Views
    604

    Traffic??? Ur kidding right , I live and work in...

    Traffic??? Ur kidding right , I live and work in the DMV area . Can't get any worst than that lol
  18. Replies
    10
    Views
    604

    Is work steady, most of my experience is in...

    Is work steady, most of my experience is in commerical but I'm not biased lol
  19. Replies
    10
    Views
    604

    Thanks, my wife and I are seriously considering...

    Thanks, my wife and I are seriously considering the move, love the area and we'd like the adventure
  20. Replies
    10
    Views
    604

    charleston sc ??

    whats the job market for commerical techs. in the area ?
  21. Replies
    71
    Views
    9,818

    no you wouldn't, i helped on one and it's...

    no you wouldn't, i helped on one and it's definitely not for me. i know my limitations and rigging is not a strong point of mine, i struggle with a 80 ton semi, no way in hell i would i ever do...
  22. Replies
    11
    Views
    1,312

    probably just a vdc valve

    probably just a vdc valve
  23. It's on a York ykcf machine . I think it is a...

    It's on a York ykcf machine . I think it is a variable orifice in the liquid line between the barrels controlled by a actuator. But Im hoping someone else can shine some light on his subject .
  24. Replies
    24
    Views
    4,047

    i hope the blowers aren't vs ???????

    i hope the blowers aren't vs ???????
  25. Replies
    12
    Views
    850

    Just bought the kobalt 4 or 5 pack ( can't...

    Just bought the kobalt 4 or 5 pack ( can't remember ) not bad quality to be honest, and I’ve grown to really like it, the main reason I bought it is because it's a heck of alot cheaper than dewalt...
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event