    Yeah, What Bald Said.

    Yeah, What Bald Said.
  2. Replies
    3
    Views
    812

    does the manual say anything about cycle rate? ...

    does the manual say anything about cycle rate?

    maybe fast and/or slow?
  3. honeywell visionpro 8000 is compatible with...

    honeywell visionpro 8000 is compatible with everything I think.

    You just have to set it up right.

    By 2/1 stage 75000 btu furnace I am assuming you mean a 2 stage furnace and an A/C?

    you...
  4. Replies
    15
    Views
    1,261

    what is a realistic estimate of how many days you...

    what is a realistic estimate of how many days you see below freezing temps?
  5. actually, when I took my test last month the...

    actually, when I took my test last month the proctor told me that they also were offering two hydronics certifacations now. gas fired, and oil fired I believe.

    of course there would be install and...
  6. Replies
    13
    Views
    1,922

    What are you paying for gas?

    What are you paying for gas?
  7. Unless you have figured out how to walk on the...

    Unless you have figured out how to walk on the ceilings this won't be an issue.



    Is there another comparable unit?
  8. Replies
    5
    Views
    915

    I would take my temp readings a little ways down...

    I would take my temp readings a little ways down the trucks instead of right at the joint even if only a foot farther.
  9. sqft means virtually nothing when sizing a unit....

    sqft means virtually nothing when sizing a unit. Run a load calculation such as Manual J
  10. First I'll say Welcome Home, and Thanks. 1)...

    First I'll say Welcome Home, and Thanks.

    1) the differance in an 80 and a 90 is about ten percent. Theoretically it should cost you about 10% less to heat with a ninty.

    2) as mentioned all will...
  11. Replies
    29
    Views
    2,798

    At the price of gas now adays I would go with a...

    At the price of gas now adays I would go with a two stage 90% w/ VS blower and a 13 SEER HP.

    And for humidity without the heat running I would get a steam humidifier.

    As for SEER versus HSPF...
  12. Replies
    16
    Views
    1,526

    And you may run into problems venting a new power...

    And you may run into problems venting a new power vented furnace into the same vent as you water heater as well.
  13. Thread: TXV

    by shank
    Replies
    15
    Views
    8,692

    TXVs either work, or they don't. Take the bulb...

    TXVs either work, or they don't.

    Take the bulb off the suction line and put it in a glass of water and let it sit for a little while. this closes a working TXV. Turn the system on and with one...
  14. Replies
    12
    Views
    921

    I thought the reason the airflow was lower was so...

    I thought the reason the airflow was lower was so the air temps would remain the same.I could see there possibly being a few degrees differance, but I would say the air would be cooler. do you know...
  15. Replies
    12
    Views
    921

    From a pure comfort aspect the Modulating 90 is...

    From a pure comfort aspect the Modulating 90 is the way to go, as long as you get the expensive modulating thermostat to go with it. If I had the money to go this way I would.

    Otherwise I would go...
  16. Replies
    16
    Views
    1,526

    Rheem if about to introduce a super quiet 80...

    Rheem if about to introduce a super quiet 80 twostage with an ECM blower.

    If I had to go 80 and could possibly get by till then this would be my choice.
  17. Replies
    11
    Views
    923

    also the units should come with installation...

    also the units should come with installation instructions you can read through them and learn alot. Matter of fact most all of them I have read have a start-up checklist in them.
  18. Replies
    16
    Views
    1,526

    the super quiet Rheem/Ruud has solid doors on it....

    the super quiet Rheem/Ruud has solid doors on it.

    I am also curious about the restrictions that only allow him to install an 80%
  19. Replies
    17
    Views
    1,349

    My guess would be the imbalance of supply and...

    My guess would be the imbalance of supply and demand of the VS motors.

    My prediction is that this time next year every unit Rheem/Ruud sell will have one except maybe the bargain units.