    Not really, because the suction pressure will...

    Not really, because the suction pressure will being to rise rather quickly to equilibrium with the ambient temp within the case. That is pressure converted to temperature. It becomes the pressure...
  2. Replies
    7
    Views
    283

    Just out of curiosity, do you have a split...

    Just out of curiosity, do you have a split condenser or heat reclaim? I would close your outlet from your receiver to see if your needle/reading moves towards 100%. Replacing a level float is not...
  3. No problem man. If your coils look good now,...

    No problem man.

    If your coils look good now, I wouldn't worry about it.
  4. Sounds like you had the wrong size nozzle...

    Sounds like you had the wrong size nozzle originally. Google this Heatcraft manual, H-IM-64J. It will explain how to properly size the nozzle

    The nozzle is not a metering device like a TXV. It...
  5. Replies
    9
    Views
    488

    Ditto on this, You need to spread out your...

    Ditto on this,

    You need to spread out your defrosts. I would go 3 to 4 a day 30-40 mins for electric defrost.

    I would check to make sure that your fan klixons are working so you can chill your...
  6. Replies
    9
    Views
    518

    First check the obvious, honeycombs, fans...

    First check the obvious, honeycombs, fans working, check strainers if applicable. Not knowing how far your condensing unit is from the cases, I would go ahead and put ports on your evaporator...
  7. Replies
    19
    Views
    909

    Dude I said nothing about resetting, read the post

    Dude I said nothing about resetting, read the post
  8. Replies
    19
    Views
    909

    When the PID for that particular circuit...

    When the PID for that particular circuit calculates that setpoint has been reached, the CDS should be at 0%, unless otherwise specified. Usually when the this valve fails it is usually due to a...
  9. Replies
    41
    Views
    1,976

    A TXV and receiver go hand in hand to compensate...

    A TXV and receiver go hand in hand to compensate for varying load conditions. Since a cap tube system is designed to handle a specific load at a specific pressure drop, I don't know how adding a TXV...
  10. Replies
    9
    Views
    414

    If it is a Copeland compressor, you can register...

    If it is a Copeland compressor, you can register at Emerson Climate Technologies' page, if you have a labtop or computer. Once you do, you have access to the OPI portal where get performance data if...
  11. Replies
    9
    Views
    617

    I believe if you go to the Emerson OPI page and...

    I believe if you go to the Emerson OPI page and select the compressor model number you desire, it is under "Performance". It shows you various data points per evaporating and condensing temperatures.
  12. Replies
    122
    Views
    6,579

    I haven't had my hand on a supermarket CO2 system...

    I haven't had my hand on a supermarket CO2 system yet. I was told by HP rep they spec out their CO2 systems with EEVs. I would like to see what a CO2 TXV powerhead looks like:whistle:
  13. Replies
    22
    Views
    1,726

    True, but the 3/8 are easier to maneuver.

    True, but the 3/8 are easier to maneuver.
  14. Replies
    22
    Views
    1,726

    Blue Vac, two Appion core remover tools, J/B 5...

    Blue Vac, two Appion core remover tools, J/B 5 cfm pump, two 3/8" vacuum rated hose, bottle of nitrogen. Quickest evacuation
  15. Replies
    122
    Views
    6,579

    I agree

    I agree
  16. Replies
    122
    Views
    6,579

    Arguing to what is superior based on who has the...

    Arguing to what is superior based on who has the "market share" of what sector is a mute argument. OEM's two biggest concerns are cost and energy consumption. The end user is mostly concern with...
  17. Replies
    13
    Views
    567

    Good time to get all the special projects done

    Good time to get all the special projects done
  18. Replies
    122
    Views
    6,579

    Have two Sporlan valves from 1965 still in...

    Have two Sporlan valves from 1965 still in operation in a supermarket air handler. Still going strong. Hussmann, Hill Phoenix, and Kysor still use them for a reason. Go in front of the RSES...
  19. Replies
    7
    Views
    599

    Hello y'all, sorry been busy...thanks for the...

    Hello y'all, sorry been busy...thanks for the replies

    Talking mainly about supermarket/commercial refrigeration. Was talking to someone who had taken the CMS test and said there was a question...
  20. Replies
    7
    Views
    599

    Unloaders on low temp envelope

    Hello, has anyone seen documentation or know why unloaders should not be installed on a low temp compressor. Thanks.
  21. Replies
    34
    Views
    2,411

    In response to the original posting, I...

    In response to the original posting,

    I understand your husband's plight, having originated from Chicago. The job market up there is tight as compared to other places, i.e. Texas, the Southeast. ...
  22. Replies
    3
    Views
    390

    E2 "Reclaim In"

    Hello everyone. My question is about the E2 Condenser control app. What is the strategy behind the "HEAT RECLAIM IN" I understand this is an input that is activated when the heat reclaim is staged...
  23. Replies
    4
    Views
    650

    24# final suction press. I have to add the box...

    24# final suction press. I have to add the box did get to 35 degree which is where the stat is set. I watched it after the kitchen closed while I was working on an ice machine. It seems the only...
  24. Replies
    4
    Views
    650

    Bad evaporator coil?

    I have a question that I think I know the answer to but I would like the advise of fellow members of the trade.

    I have a walk in cooler that runs on 12 with a evaporator that is looks pretty beat...