    NOPE 24V DOESENT CARE ..COURSE THE SCHEMATIC IS...

    NOPE 24V DOESENT CARE ..COURSE THE SCHEMATIC IS GONE TOO??,,,24 IS A SERIES CIRCUIT and different timing is inside each
    sequencer.
  2. Replies
    5
    Views
    267

    The sequencer is a switch... on the hot side.....

    The sequencer is a switch... on the hot side.. common would go to the other end of the heat strip. with common on one side and hot on the other you will blow the breaker when the sequencer closes!!...
  3. Replies
    23
    Views
    1,175

    Rheem flame sensor secret

    New board requiring the flame sensor kit.. It wouldnt work. Change control board twice, fix by sanding off the burner. Pulled the burner and cleaned the end and the inside of the lip. Lots of white...
  4. Replies
    5
    Views
    435

    my manifold went bad!

    my manifold went bad!
  5. Replies
    5
    Views
    435

    Answer: my yellow jacket manifold went bad.....

    Answer: my yellow jacket manifold went bad.. rebuilt time!!
  6. Replies
    5
    Views
    435

    pump freon into condenser w G5

    So MY OWN install, I evacuated after pressure testing with nitro. HUH?? It would suck in but 6 oz of R22. Well it was record high forecast for today. 95 in Portland, OR. So I thought I would pump and...
  7. Replies
    13
    Views
    1,376

    just google ac motor power comsumpsion.. Small...

    just google ac motor power comsumpsion.. Small than designed motor will overheat and
    fail. Load has to be match to the mechanical and electrical load...
    One horsepower is 640 watts as I recall.....
  8. Replies
    4
    Views
    589

    some dirty RAT

    took the drawing I needed.....
  9. Replies
    3
    Views
    341

    call the gas company!!

    something loose on the meter outside most likely..
    They usually will come out ASAP..
    They just dont like big booms or
    fires...

    DO IT NOW>> they respond 24-7 if a serious leak..
  10. Replies
    5
    Views
    814

    Knowing the sequence of operation is a big...

    Knowing the sequence of operation is a big help..you figured out..on cooling the combust
    blower shouldnt be running.. I'd have run it in heat mode too.

    You did verify that the combust blower...
  11. Replies
    4
    Views
    1,185

    fOUND SOME SECHEMATICS

    POKED Around on the web and found a couple of drawings..
    I should be able to figure it out..

    new relay. 6 connections 2 coil one normal open and closed..
    I've got a plan now!! [way scary huh!!]...
  12. Replies
    4
    Views
    1,185

    I tried..

    I did put in a standard one.. no change
    I tried to straight line the wiring, but that didnt help..
    seemed simple enough
    2 coil wires
    1 speed heat/1 speed cool. Its like one leg of the 220 is in...
  13. Replies
    4
    Views
    1,185

    YORK AIR HANDLER FAN RELAY

    ITS got no schematic. the relay label is gone. York tech support..
    we dont have the info its too old...

    Fan runs all the time. I think its misswired.

    model MCB36-6B SN --JM17753B or the...
  14. Wow!! well the air temp wont be a fire hazard.....

    Wow!! well the air temp wont be a fire hazard.. but I hope they are all in interior walls.
    Otherwise the heat loss will be really terrible..
    SO the registers are in the walls, with no "boot" metal...
  15. Replies
    13
    Views
    1,014

    what they know..

    On average the TECH can install, but the INSTALLER usually doesnt have the
    experience,knowledge or tools to be a TECH. Doing something by rote is
    nothing like troubleshooting.

    Yep every...
  16. Replies
    36
    Views
    2,160

    board problem

    I usually find the control board is cutting off ignition too soon b4 the the valve opens.
    There needs to be reasonable overlap between gas and lighting device.
    4 seconds anyway...
    Never had the...
  17. Replies
    3
    Views
    385

    Lots of locations can cause this problem

    Best to have your pro technician have a look. If not, more damage can
    happen.
    Smart homeowners know when to call in the experts!
  18. Replies
    4
    Views
    541

    each one different

    Seems every inspector has a favorite area.. Maybe electrical, or venting
    sometimes it depends on their workload, if they have 14 places to go to,
    including travel time they may be onsite for 5...
  19. Replies
    2
    Views
    388

    Heat pumps move BTU, the temp is affected by many...

    Heat pumps move BTU, the temp is affected by many factors, If not properly charged
    duct configuration and insulation of them. Air speed.. Each system has a totally different
    duct setup Im sure.....
  20. Replies
    8
    Views
    905

    part was defective... bad before/repalce part now...

    part was defective... bad before/repalce part now works... There wasnt a model B on his truck..
  21. Replies
    23
    Views
    1,373

    1. I'd start with the compressor rating and see...

    1. I'd start with the compressor rating and see if it REALLY 36K btu.. manufactures are
    often off of the rating with smaller compressors.

    2. Course you cant test the AC cause its too cold??...
  22. To be usually legal in most counties the...

    To be usually legal in most counties the manufactures manual is the BIBLE.

    Some insurance companies check to see if equipment was permited after the fire....
    but im sure your going to get a home...
  23. You get to lay down on these jobs...

    Some are designed with better access for service. Some gas valves
    are challenging to change when that comes around.

    Course cash payers are the best!

    My favorite light with magnets on the back...
  24. Replies
    17
    Views
    798

    Time to call a pro

    Sounds like a problem..

    out door fan should be running anytime you hear "buzzing"
    If not, please prevent damage by turning off at the thermostat
    and calling your service provider.
    Dont wait as...
  25. Thread: yorks

    by fixitguy
    Replies
    1
    Views
    293

    yorks

    Hi GUys I need a schematic for an air handler or electric furanace
    N2AHD14A06C

    There is none on the unit!! thanks.
    DON in PDX
Results 1 to 25 of 277
Page 1 of 12 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event