Search:
Type: Posts; User: hotcoldtech
Search: Search took 0.00 seconds.
-
10-19-2006, 10:54 PM
Thread: who makes federal???
by hotcoldtech- Replies
- 1
- Views
- 326
http://www.federalind.com/
http://www.federalind.com/
-
11-17-2004, 09:57 PM
Thread: TTS Stench
by hotcoldtech- Replies
- 6
- Views
- 2,144
Hey Taylor, we had a tech that worked for us,...
Hey Taylor, we had a tech that worked for us, went on a call on a taylor twin at a national chain. both water cond. exploded out, like the water froze in them. after doing some investigating, found...
-
11-10-2004, 07:43 PM
Thread: Head scratcher for the refers....
by hotcoldtech- Replies
- 22
- Views
- 1,858
Baub, If my memory serves me correctly, I...
Baub, If my memory serves me correctly, I believe on True freezers (not sure what all models) they are cycling the evap. fans with the condensing unit/ t'stat, supposedly to get their energy rating....
-
11-02-2004, 06:41 PM
- Replies
- 18
- Views
- 1,750
So I forgot the drain part icemeister. Just...
So I forgot the drain part icemeister. Just checking to see if you're on your toes. Another one of those days where the brain is working faster then the hands!!
-
11-02-2004, 02:56 PM
- Replies
- 18
- Views
- 1,750
don't forget to make sure that the isn't plugged...
don't forget to make sure that the isn't plugged up. forgot that part a few times trying to rush things and get done. OOPS!!!
-
11-02-2004, 02:44 PM
Thread: scottsman ?
by hotcoldtech- Replies
- 7
- Views
- 1,712
Right you are boat racer! Talk about being johnny...
Right you are boat racer! Talk about being johnny on the spot!!!! Now that's service.
-
11-01-2004, 04:09 PM
Thread: Beacon II System
by hotcoldtech- Replies
- 4
- Views
- 613
Hey Lusker just thought I'd let you know you win...
Hey Lusker just thought I'd let you know you win the prize. Went back today and checked thoroughly though the wiring. Found a small spot where the fan lead and the lead for the relay on the beacon...
-
11-01-2004, 12:14 AM
Thread: Beacon II System
by hotcoldtech- Replies
- 4
- Views
- 613
good point--didn't look at those wires that...
good point--didn't look at those wires that close. Based on the time the fuses blew, it was within about 15 minutes before or after the defrost cycle. I had the manager keeping a close eye on it...
-
10-31-2004, 11:04 PM
Thread: Beacon II System
by hotcoldtech- Replies
- 4
- Views
- 613
Got a call this morning from McDonalds. Walk-in...
Got a call this morning from McDonalds. Walk-in freezer @ 25. Smart controller displaying comm error. 20amp fuses for freezer evap. on CU blown. Checked wiring from CU to evap., heaters, fans,...
-
10-28-2004, 02:57 PM
Thread: Ever Seen One Like this?
by hotcoldtech- Replies
- 26
- Views
- 1,511
a massager would be fabulous, but she might cost...
a massager would be fabulous, but she might cost to much, unless you're going to be there a while.
-
10-28-2004, 12:25 PM
Thread: Ever Seen One Like this?
by hotcoldtech- Replies
- 26
- Views
- 1,511
A lazyboy recliner would be nice too. would fit...
A lazyboy recliner would be nice too. would fit right in with the rest of the job.
-
10-18-2004, 08:08 PM
Thread: Wilch Slush Machine
by hotcoldtech- Replies
- 16
- Views
- 3,958
Parts for the old Wilch machines are becoming...
Parts for the old Wilch machines are becoming extinct. The lovejoy couplings and sequencers you can get from graingers. Wilch may have some parts left depending on what you're looking for. Not...
-
10-13-2004, 12:17 PM
Thread: New condensing unit, what gas to use?
by hotcoldtech- Replies
- 20
- Views
- 2,117
Being from the Iowa, I prefer 404a over 134a...
Being from the Iowa, I prefer 404a over 134a because of suction pressure runs higher. extreme cold days with R12 and R134a pressure switches have to be set into vaccuum to keep the units running....
-
10-04-2004, 01:47 PM
- Replies
- 9
- Views
- 825
usually the only function of that timer is to...
usually the only function of that timer is to agitate the ice to keep it from becoming one big block. Manitowoc uses them also on their dispensers. We have by-passed them only if the dispenser is...
-
09-14-2004, 11:30 AM
Thread: New condensing unit, what gas to use?
by hotcoldtech- Replies
- 20
- Views
- 2,117
Have you considered R404a? Works extremely well...
Have you considered R404a? Works extremely well in med.temp applications. I prefer that over R134a.
-
09-09-2004, 11:05 PM
Thread: Undercounter Scottsman Ice Maker
by hotcoldtech- Replies
- 6
- Views
- 1,034
I have had to work on these models for different...
I have had to work on these models for different home owners. The biggest problem I found was that the although the condenser appeared to be clean, because of the condensers small size, it didn't...
-
09-07-2004, 07:47 PM
Thread: Manitowoc Ice machine
by hotcoldtech- Replies
- 8
- Views
- 859
Although they are a nice source of income, they...
Although they are a nice source of income, they can be a pain in the a**. You can use a single wire probe on the e & g series machines or convert the two prong into a single wire by grounding one of...
Results 1 to 17 of 18

