  1. Replies
    6
    Views
    431

    I agree biggest waste of money i bought one 2...

    I agree biggest waste of money i bought one 2 months ago never could get it down past 3500 microns as soon as you valved off would go all the way up again hooked it directly to pump same bs..would go...
  2. Replies
    4
    Views
    243

    Sounds like people are not shutting door properly...

    Sounds like people are not shutting door properly or the gasket isn't sealing correctly causing moisture to to freeze the door glides
  3. how many water valves are in the back of fridge...

    how many water valves are in the back of fridge sometimes theres 2 one on each side if you go to searspartsdirect.com and put you model in it will show you a diagram and it will help you find which...
  4. I know from experience with this you have to...

    I know from experience with this you have to replace the board and the evap fan at the same time something with the frequency or something GE guy said that one time sometimes they make howling noise...
  5. Replies
    9
    Views
    436

    manometer

    manometer
  6. Replies
    23
    Views
    1,031

    ive always noticed the installer gets pissed off...

    ive always noticed the installer gets pissed off at the service techs because they get payed more but the techs are on call and don't have a normal 8 to 5 also most service tech could do the install...
  7. Thread: compressor

    by brnestes
    Replies
    1
    Views
    202

    compressor

    came to a RTU today not cooling compressor running sounded funny equalized psig on manifold. 3 phase wiring was reversed suction line was real warm haha. the last company who had contract I think...
  8. thats great

    thats great
  9. Replies
    25
    Views
    4,223

    I love my 570 had a little over 2 yrs only...

    I love my 570 had a little over 2 yrs only problem I have is the little rubber covers that cover ports are worn out come off sometimes especally the top one its completely ripped off but it still...
  10. water valve for sure that's pretty common.. if...

    water valve for sure that's pretty common.. if that center partition is hot to the touch make sure that condenser is clean and the condenser fan is running ..repairclinic.com has all the parts you...
  11. Replies
    16
    Views
    808

    Nothing stops a Trane haha

    Nothing stops a Trane haha
  12. Thread: defrost

    by brnestes
    Replies
    4
    Views
    270

    bottom left corner behind kickplate

    bottom left corner behind kickplate
  13. Replies
    18
    Views
    907

    H10 Nuff said

    H10 Nuff said
  14. Replies
    8
    Views
    471

    Multimeter and ampmeter and your basic hand...

    Multimeter and ampmeter and your basic hand tools set of refrigerant gauges and a tool bag
  15. Replies
    71
    Views
    4,421

    I have my veto for about yr and half I like it...

    I have my veto for about yr and half I like it but the zippers didn't last and I don't have time to send it in
  16. ive seen a couple of secondarys were they start...

    ive seen a couple of secondarys were they start rusting underneath and drip into the blower housing. I sometimes test with a combustion analyzer I had one were it was plugged up tripping the roll out...
  17. Replies
    10
    Views
    976

    TruTechTools are the best in the business I get...

    TruTechTools are the best in the business I get things from them all the time !!!!
    website is sweet too
  18. Replies
    6
    Views
    664

    combustion analyzer for sure pulling the burners...

    combustion analyzer for sure pulling the burners checking inside each cell if the partition plate has a crack you know the heat exchanger got to have a crack
  19. mA reading ?

    mA reading ?
  20. Replies
    10
    Views
    3,221

    ive had nothing but problems with that pump ive...

    ive had nothing but problems with that pump ive seen them go bad in a month little giant is the best I think
  21. Replies
    43
    Views
    2,830

    I remember NATE came out they said it would be...

    I remember NATE came out they said it would be advertised on tv and its like the ASE certification in the car mechanic industry "which isn't true" and everyone would recognize it.... nobody even...
  22. Replies
    12
    Views
    2,032

    My favorite is a finished basement and they build...

    My favorite is a finished basement and they build the mechanical room with a wall right in front of furnace... have to cut a hole in wall to pull blower assembly
  23. Replies
    11
    Views
    1,319

    Diversitech is junk little giant s are better

    Diversitech is junk little giant s are better
  24. Replies
    28
    Views
    1,631

    I've had the 570s for a year the best out there...

    I've had the 570s for a year the best out there if you put em back in the case like your supposed too they'll last no tool las t long if rolls around in the back of van
  25. Replies
    47
    Views
    4,878

    I have all my own tools I like it that way I even...

    I have all my own tools I like it that way I even have my own recovery tank Haha I don't have to worry for extra side work owner saying anything bout using his tools ya know