Search Results - HVAC-Talk: Heating, Air & Refrigeration Discussion

Search:

Type: Posts; User: Swampfox

Page 1 of 20 1 2 3 4

Search: Search took 0.04 seconds.

  1. Replies
    13
    Views
    964

    I worked on the oceanfront for years, those units...

    I worked on the oceanfront for years, those units are in great shape
  2. I quit drinking, Im on too many drugs

    I quit drinking, Im on too many drugs
  3. He is AKA PaysonHVAC

    He is AKA PaysonHVAC
  4. Replies
    10
    Views
    958

    Chinese Kwality

    Chinese Kwality
  5. Thread: iPhone help

    by Swampfox
    Replies
    4
    Views
    466

    Try this ...

    Try this

    http://itunes.apple.com/us/app/user-agent-browser-simply/id414229165?mt=8
  6. They arent leftists, Im pretty sure they are...

    They arent leftists, Im pretty sure they are libertarian, they really dont care who they offend either
  7. They never intended for anyone to replace parts...

    They never intended for anyone to replace parts in these things lol

    Some are still around because of those Carlyle recips, I think they might run forever
  8. Replies
    52
    Views
    8,768

    Click your name at the top

    Click your name at the top
  9. Replies
    52
    Views
    8,768

    VB4, the Windows Vista of forum software lol ...

    VB4, the Windows Vista of forum software lol

    should have waited for VB5, it wont be long now
  10. Replies
    10
    Views
    3,612

    There is a service bulletin out on this, speed...

    There is a service bulletin out on this, speed tap #4 on a certain date range of equipment has an issue with low resistance, causing a low voltage short

    There is definitely a reliability issue...
  11. The variable speed blower settings are likely set...

    The variable speed blower settings are likely set wrong
  12. Replies
    32
    Views
    2,377

    The 2 lines are identical

    The 2 lines are identical
  13. Replies
    32
    Views
    2,377

    Every manufacturer is using POS Chinese reversing...

    Every manufacturer is using POS Chinese reversing valves, only way to avoid them is stop selling heat pumps
  14. Yeah, not the same wiki, Wikipedia is a free...

    Yeah, not the same wiki, Wikipedia is a free online encyclopedia and has nothing to do with Wiki Leaks

    Everyone needs to get involved in this if you want to keep the internet free and open, set...
  15. When I was young (and poor) I installed a used...

    When I was young (and poor) I installed a used system in the house I was renting, there was insufficient electrical service for auxiliary heat, as expected the defrost cycles caused a problem, I...
  16. Replies
    4
    Views
    1,165

    You can have it converted to the updated defrost...

    You can have it converted to the updated defrost control also, part # is PCBDM133S

    It does require some minor wiring changes though
  17. There are generic electronic defrost controls...

    There are generic electronic defrost controls that can be retrofitted to pretty much any heat pump, The old Amana would be one of the most challenging though, you'll need someone who really knows...
  18. Replies
    20
    Views
    3,109

    That is called the spider design, its right out...

    That is called the spider design, its right out of ACCA manual D, not saying its ideal, but its not something a hack pulled out of his rear either.
  19. Replies
    34
    Views
    2,620

    Not if you disconnect it first

    Not if you disconnect it first
  20. Replies
    34
    Views
    2,620

    If the 3 pipes are facing up I cut out with a...

    If the 3 pipes are facing up I cut out with a sawzall right at the valve body, then sweat the stubs off 1 at a time, If they face down I use 2 torches and a helper to sweat the valve out, then braze...
  21. You say you have an air handler yet you are...

    You say you have an air handler yet you are quoting instructions for a cased coil

    On the 4TEE model you flip the coil, unless you want condensate going everywhere, the coil apex will face the...
  22. An XE 1000 has demand defrost, with a coil...

    An XE 1000 has demand defrost, with a coil thermistor the slips into a tube at the bottom of the coil, it has yellow wires, and its on the control panel side of the coil

    The part in the picture is...
  23. Replies
    5
    Views
    566

    Its an over/under package heat pump, 12 SEER ...

    Its an over/under package heat pump, 12 SEER

    http://www.trane.com/webcache/un/packaged%20heat%20pumps%20%28pkgp%29/product/12-1253-05_03012009.pdf
  24. Replies
    24
    Views
    1,307

    Let an exterminator handle that I hate bees

    Let an exterminator handle that

    I hate bees
  25. Replies
    15
    Views
    1,230

    new hoses? sounds like you didnt have the...

    new hoses? sounds like you didnt have the schrader pushed in very far, the thick seal on a brand new hose can sometimes cause that problem, sure sign is the suction takes a long time to drop back...
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event