Search Results - HVAC-Talk: Heating, Air & Refrigeration Discussion

Search:

Type: Posts; User: kls-ccc

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds; generated 53 minute(s) ago.

  1. Replies
    29
    Views
    686

    I have been driving a Express 3500 for 15 years. ...

    I have been driving a Express 3500 for 15 years. When I ordered it I made sure it had the positrack rearend and the 5.7 V8. Between the weight and the locking differential I can go about anywhere....
  2. Depending on the age of the coil and how it...

    Depending on the age of the coil and how it looked I don't see a problem using it. Just because the new coil is 50% bigger does not make it better or make the system in effective. I have read...
  3. Replies
    22
    Views
    691

    The politically correct term is "Vertically...

    The politically correct term is "Vertically Challenged".
  4. Replies
    22
    Views
    691

    No.

    No.
  5. I think you are looking at the situation wrong. ...

    I think you are looking at the situation wrong. You want to know if you are paying to much, the question should be are you getting what you need. Let's say you pay the $ and it doesn't work, you...
  6. Replies
    21
    Views
    465

    What product are we using to much of now? Since...

    What product are we using to much of now? Since magnetism is directly related to electricity that must be it. Every time you run that power tool your screwing up the planet, so stop it. So doe...
  7. Replies
    25
    Views
    1,021

    Have you ever bought water in a 16 oz bottle from...

    Have you ever bought water in a 16 oz bottle from a convenience store? It's about a buck, basically tap water. How many gallons of water can you get out of your tap for that same buck, I get about...
  8. Replies
    19
    Views
    724

    I use to have a set for 22 and another for 410. ...

    I use to have a set for 22 and another for 410. I had valves on the end of the hoses and would drain the high side back to the low side before I took them off. So they always had the suction...
  9. Replies
    10
    Views
    360

    If the unit has never been installed and the...

    If the unit has never been installed and the seals held most of the charge you need should be there. I don't see an issue with installing it from a regulation stand point. R-22 units are still...
  10. I remember a double header one day. I was...

    I remember a double header one day. I was changing a compressor in the morning, had just gotten done brazing a filter/drier to a copper line, got stupid and grabbed it to put it into the unit. ...
  11. Replies
    28
    Views
    828

    The 600 CFM is the rating at 100 equivalent feet....

    The 600 CFM is the rating at 100 equivalent feet. 2 elbows at worst case are equal to 30' each.
  12. Replies
    28
    Views
    828

    Maybe I missed it but why are you trying to add a...

    Maybe I missed it but why are you trying to add a booster fan to the return and not the supply, i.e. push the air up rather than try and pull it up?

    18x7 dust will move about 600 CFM @ .08 static,...
  13. I ran into a manufacturing plant that had a bunch...

    I ran into a manufacturing plant that had a bunch of rooftop units with R traps instead of P traps. The outlets were higher than the inlet. They had the building contractor and the HVAC company out...
  14. [QUOTE=2056bill;18691381]yes. I also checked...

    [QUOTE=2056bill;18691381]yes. I also checked today it has bulb to clamp.[/QUO

    Bulb or no bulb, that is the question. If there is no bulb, there may not be anything else either. If there is a...
  15. And so how is that different than 90% of all the...

    And so how is that different than 90% of all the other companies out there including HVAC firms. There are some companies where product/service comes first money is second. Those companies are few...
  16. When are people going to realize that the problem...

    When are people going to realize that the problem isn't as much the insurance Co. as it is people NOT taking responsibility for their health care. I know people {and a lot of them} that see an...
  17. Thread: Got shocked

    by kls-ccc
    Replies
    48
    Views
    3,047

    Not to discount what happened to the OP because...

    Not to discount what happened to the OP because of sloppy workmanship I ran into a unit installed in 2001 with no disconnect. Why let something like the NEC get in the way of making money.
  18. Replies
    10
    Views
    423

    Looking at the numbers posted 223 on a 70*OA is...

    Looking at the numbers posted 223 on a 70*OA is high which makes me think overcharge or dirty condenser. 2*SH and 19* SC makes me lean to overcharge. On old R-22 systems it use to be OA +30*, IA...
  19. From what I have seen, read and heard I think our...

    From what I have seen, read and heard I think our government worked pretty well up until sometime between the Civil war and the Great Depression. So what happened during that time that it started to...
  20. It always bothers me when some one equates...

    It always bothers me when some one equates organized religion with God. Organized religion is a political system just like any government, it is set up with traditions and doctrine created by man. ...
  21. Replies
    15
    Views
    419

    I just got a Trane motor, it was in a US motors...

    I just got a Trane motor, it was in a US motors box, I have some older ones with GE on them. If the Emerson has the same specs I wouldn't worry about it.
  22. Replies
    90
    Views
    2,666

    I think Spock said it best when he said "The...

    I think Spock said it best when he said "The needs of the many outweigh the needs of the few." So some of the liquid refrigerants sacrifice themselves so the rest can stay liquid. What brave little...
  23. The compressor in the system is filled with...

    The compressor in the system is filled with enough oil so some can migrate out into the system with the refrigerant and still have enough to keep the compressor lubricated. Compressor oil rarely...
  24. Thread: Freezing Coil

    by kls-ccc
    Replies
    31
    Views
    1,806

    Here's the way I see it. The unit is...

    Here's the way I see it. The unit is overcharged, It cools down to the mid to upper 60's and the TXV closes off as tight as it can because it wasn't designed to cool that low. With the TXV closed...
  25. Thread: Air flow

    by kls-ccc
    Replies
    2
    Views
    207

    Is it possible, yes. It all depends on how...

    Is it possible, yes. It all depends on how restrictive the old registers were. If the system was running .98 ESP with the old registers and it dropped to .44 ESP then yes. If it was running .44...
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event