  1. Thread: Best vaccum pump

    by splus
    Replies
    57
    Views
    1,924

    Get yourself a BBH= BIG BLACK HOSE,IT DRIVES ME...

    Get yourself a BBH= BIG BLACK HOSE,IT DRIVES ME NUTS WHEN TECHS GOT A YELLOW HOSE ON THE PUMP
  2. Replies
    7
    Views
    396

    the bottom of the Coil was frozen solid on both...

    the bottom of the Coil was frozen solid on both sides with a little bit of ice on the top middle of the coil didn't have any
  3. Replies
    7
    Views
    396

    Its 6 year's old,I am betting low charge but then...

    Its 6 year's old,I am betting low charge but then I need to find the leak
  4. Replies
    7
    Views
    396

    FROZEN COIL QUESTION

    Get to a call where the customer tells me its cooling but not like it should be,i get to the outdoor unit which is running with not alot of heat expelled from the fan.Before i coud get my guages on...
  5. Replies
    6
    Views
    340

    Good point using the coupling I guess i will get...

    Good point using the coupling I guess i will get some also
  6. Replies
    6
    Views
    340

    Nordyne txv valve with brazed equi.line

    Nordyne 669556 txv valve has a brazed in equalizer line its r22 5 ton i have alot of these out there and wanted a txv valve on the truck.do you unbraze the one thats there and attach the new...
  7. Replies
    7
    Views
    489

    This model down not have it.I'm not quite...

    This model down not have it.I'm not quite understanding why the blower works in heating mode but nothing else
  8. Replies
    7
    Views
    489

    Not sure what you mean by model plug,both the...

    Not sure what you mean by model plug,both the control and the blower board have been changed.i did talk to the owner of another company who told me about a white sticker on the blower board.any way i...
  9. Replies
    7
    Views
    489

    ICP H9MVX BLOWER ISSUE

    When i arrive at the call the furnace led was blinking normal standby code,on a call for heat nothing would happen even after bybass the stat.Both boards were replaced as the blower board had some...
  10. Replies
    20
    Views
    1,273

    Well i am starting this replacement tommorow and...

    Well i am starting this replacement tommorow and after a talk with the homeowner i am running a new line set inside a speedi channel cover on the outside of the house.
  11. Replies
    20
    Views
    1,273

    line set buried in the wall

    Doing a whole replacement attic system where line set replacement is not possible its inside the wall.while removing the old system i notice it was not BRAZED but soldered.I am thinking about putting...
  12. Replies
    1
    Views
    207

    LENNOX VENTING QUESTON

    The venting chart on the e195 furnaces only gives the footage for pipe with the number of 90 degree elbows.Is it correct that two 45 degree elbows equal one 90 degree elbow?
  13. Replies
    1
    Views
    182

    I always use a good air scoop and never have any...

    I always use a good air scoop and never have any issues.
  14. Replies
    0
    Views
    166

    EMI MINI SPLIT ISSUE

    Mod #zha2400 heat pump model,customer tells me the outdoor fan never shuts off.Put in high cool mode suction is 120psi and cooling well shut system of and outdoor fan never shuts off so i take the...
  15. Replies
    2
    Views
    347

    Going there in the am to check it out,it sounds...

    Going there in the am to check it out,it sounds like its coming from the back of the heat exchanger but thats just me
  16. Replies
    15
    Views
    1,542

    Service is up a tad and thats it,had 2 customers...

    Service is up a tad and thats it,had 2 customers this week decide to buy there parts online not sure if they called back as there number is now blocked.The only furnace changeout i did was 3 weeks...
  17. Replies
    2
    Views
    347

    Lennox el195 clicking sound

    Lennox el195 installed 2 weeks ago and the customer can hear a clicking sound coming from the inducer and from the vent pipe outside.I have always heard a faint sound from all of these but run with...
  18. Replies
    20
    Views
    1,966

    it's vented with 2 inch 35 feet total with...

    it's vented with 2 inch 35 feet total with fittings I went there today made sure there was enough pitchback on the vent pipe also thinking if there was built up water when the inducer shut off any...
  19. Replies
    20
    Views
    1,966

    i am going there in the morning to see what i find

    i am going there in the morning to see what i find
  20. Replies
    20
    Views
    1,966

    No water in collector box.I pull inducer and...

    No water in collector box.I pull inducer and drain it it did this a week ago and I checked it 3 days ago and everything seemed to be draining fine I could not hear any water in inducer
  21. Replies
    20
    Views
    1,966

    Flu is pitched with no standing water in...

    Flu is pitched with no standing water in pipe,might locate trap at collector box it runs for a week that has me stumped
  22. Replies
    20
    Views
    1,966

    Lennox el296v drainage issue

    I have a el296070 furnace that runs fine for 2 weeks and then the inducer fills with water and shuts the unit down.The trap is not installed at the collector its at the rear of the furnace about 30"...
  23. Replies
    1
    Views
    307

    Coleman roof jack question

    I am changing a coleman model number 4084a656 to an updated model number dgaa075bdtb and need to know if the roof jack jacks are compatible?The one thats there is in great shape and changing it is...
  24. Replies
    2
    Views
    386

    Lennox vent termination kits

    Anyone using the diversitech hvent2 or hvent3 for vent terminations?There half the cost of the lennox ones.
  25. Replies
    5
    Views
    593

    ICP pressure switch issue

    Icp mod n8npm050b from 2006,the burner lights for 20 seconds and goes out.Flame sensor was good check pressure switch operation which closes at -.58 and goes to .-64 but when the burner lights it...
  26. Replies
    7
    Views
    591

    I will do that Jeep Sent from my Torque using...

    I will do that Jeep

    Sent from my Torque using Tapatalk
  27. Replies
    7
    Views
    591

    Thanks dawg i updated my profile and sent you a...

    Thanks dawg i updated my profile and sent you a message also
  28. Replies
    7
    Views
    591

    LG LS090CE MINI SPLIT

    Does anyone have a troubleshooting guide or parts manual for this mini-split,the comp starts but the condensing unit fan motor never starts and the system shuts down in a few min.
  29. Replies
    3
    Views
    445

    Subcool reading was taken at the condenser ...

    Subcool reading was taken at the condenser

    Sent from my Torque using Tapatalk
  30. Replies
    3
    Views
    445

    76 degrees Sent from my Torque using Tapatalk

    76 degrees

    Sent from my Torque using Tapatalk
  31. Replies
    3
    Views
    445

    H/V CHARGING ISSUE

    New system startup 2.5 ton r-410 h/v system readings are,s/h=12,s/c=3 12 deg d/t, low side 118psi,high side 195 psi.The first floor is a walkout basement temp was 70 deg second floor 75 deg both have...
  32. Baldies got it right there I've had four leakers...

    Baldies got it right there I've had four leakers all c6 miles to the three years old

    Sent from my Torque using Tapatalk
  33. Thread: run cap question

    by splus
    Replies
    51
    Views
    4,680

    I would change it to the right one for sure what...

    I would change it to the right one for sure what will it harm the motor having the bigger one on there

    Sent from my Torque using Tapatalk
  34. Thread: run cap question

    by splus
    Replies
    51
    Views
    4,680

    run cap question

    Was on a call where there was a 7.5 cap on a motor that called for a 5mfd cap,was installed 2 years ago and running fine.Will this be okay if left like this?
  35. My company WAS installing nordyne equipment for...

    My company WAS installing nordyne equipment for 15 yearswith no issues until the microchannel systems came out.Most leakers dont show up until the second year and trying to find them have been not...
  36. Replies
    2
    Views
    321

    Thanks dawg Sent from my Torque using Tapatalk

    Thanks dawg

    Sent from my Torque using Tapatalk
  37. Replies
    2
    Views
    321

    Lennox c33 liquid line stub

    Is the 3/8od liquid line stub available as a part if so i need a part number,also the one that comes with the coil has a teflon o-ring on it do i need to install the o-ring that comes inside the coil...
  38. Replies
    2
    Views
    352

    So a standard 2.5 ring will work if OEM is larger...

    So a standard 2.5 ring will work if OEM is larger

    Sent from my Torque using Tapatalk
  39. Replies
    2
    Views
    352

    Trane blower motor question

    Trane part number moto4717 3/4 hp motor,need to know if a standard motor with 2.5 inch resilient rings will work I seem to remember some of these have 2/5/8 rings
  40. Replies
    12
    Views
    980

    The chimney has a tile liner in it now its been...

    The chimney has a tile liner in it now its been running fine for 2 days now told the customer we need to evaluate the chimney and possibly put a alum liner in it

    Sent from my Torque using Tapatalk
  41. Replies
    12
    Views
    980

    The chimney is on the outside of the house and we...

    The chimney is on the outside of the house and we have had a week off record cold here below zero wind chill

    Sent from my Torque using Tapatalk
  42. Replies
    12
    Views
    980

    Yes it will vent fine no spillage at the water...

    Yes it will vent fine no spillage at the water heater I haven't taken any draft reading yet its been venting and the boiler and then cycling for 24 hours

    Sent from my Torque using Tapatalk
  43. Replies
    12
    Views
    980

    After pulling the vent pipe off of the vent...

    After pulling the vent pipe off of the vent damper of the boiler letting it bent into the basement for a minute putting the vent pipe back on the damper in its been venting fine

    Sent from my...
  44. Replies
    12
    Views
    980

    The boiler is 125000 BTU with a 40,000 BTU...

    The boiler is 125000 BTU with a 40,000 BTU standing pilot water heater jimmy is on the outside of the house 8 inch tile lined

    Sent from my Torque using Tapatalk
  45. Replies
    12
    Views
    980

    It extends one inch into the flu I checked it a...

    It extends one inch into the flu I checked it a fee hours later and it was venting fine

    Sent from my Torque using Tapatalk
  46. Replies
    6
    Views
    800

    Triangle tube boiler with the trimax control is a...

    Triangle tube boiler with the trimax control is a nice boiler.W/M makes a fire tube boiler also which is pretty much the same heat exchanger.
  47. Replies
    12
    Views
    980

    Boiler draft issue

    Get to a no heat call on a natural draft spark ignition boiler and find the roll out under the draft hood tripped.Boiler fires and I notice its not venting at all as in the vent pipe after the vent...
  48. Thread: Wet Switches

    by splus
    Replies
    9
    Views
    1,403

    I have used a hair dryer but have found to just...

    I have used a hair dryer but have found to just replace it as most will trip if there is high humidity in the attic area there very sensitive after you dry them
  49. Replies
    2
    Views
    632

    LINE SET SIZE QUESTION

    Got a trane 4ttb3018 with a 4txc18 coil i serviced it a few years back and it has a 5/8suction with a 1/4 liquid line.another company looked at it as i was 5 days out and said the liqiud line size...
  50. Replies
    2
    Views
    686

    ADP TXV PART NUMBER

    adp #te36430c245b 5-ton made in 2007 its a r-22 coil with txv i need a r-410 valve i did have one from a trane 4txc coil but the threads dont match up anyone know the adp or trane part number for the...