  1. Thread: TXV woes

    by mdnbiker
    Replies
    2
    Views
    459

    had a 1 ton in it, bolt in, and sized to unit.

    had a 1 ton in it, bolt in, and sized to unit.
  2. Replies
    5
    Views
    678

    sounds about right to me......

    sounds about right to me......
  3. Thread: TXV woes

    by mdnbiker
    Replies
    2
    Views
    459

    TXV woes

    Walk in cooler had a compressor tripping internal O/L, high amps, high head. Replaced the condensing unit with new TXV. Start up, let runabout an hour, compressor slugging, no superheat.
    Attempted...
  4. Replies
    46
    Views
    2,730

    if being hot bothers you....stay away if being...

    if being hot bothers you....stay away
    if being cold bothers you...stay away
    if getting dirty bothers you...stay away
    if other than 8 to 5 bothers you... stay away
    if smelling like things you...
  5. Replies
    6
    Views
    897

    You can reduce the water pressure with a clamp on...

    You can reduce the water pressure with a clamp on the hose running to the distrbution bar. You may also need to replace the ice thickness probe or make sure the old one is clean, dry and adjusted ...
  6. Replies
    18
    Views
    5,852

    i work on ice machines almost every day..Alot of...

    i work on ice machines almost every day..Alot of my time is spent waiting. ice machines are not hard to service but you need to know what it is supposed to be doing and when it should be doing...
  7. Replies
    18
    Views
    5,852

    when you say overfull do you mean it is full...

    when you say overfull do you mean it is full above the bin t-stat? when I say clean the machine I mean clean the evap with the proper evap cleaner, clean the water distibution system, clean the...
  8. Replies
    18
    Views
    5,852

    Clean the machine Is the red light on solid or...

    Clean the machine Is the red light on solid or blinking? has the unit been cleaned? I think you said you have a service guide. 2 failed harvest, high evap temp,, or open thermister. take your...
  9. Replies
    10
    Views
    791

    either one will work. only diff will be timed or...

    either one will work. only diff will be timed or temp, you choose
  10. Replies
    10
    Views
    791

    break power to the curtain switch

    break power to the curtain switch
  11. Replies
    15
    Views
    1,017

    To shorten the water level probe on a S...

    To shorten the water level probe on a S model...remove it from machine, cut or grind 1/4 inch from probe and reinstall it. This info was given to me by Manitowoc tech support
  12. Replies
    9
    Views
    706

    As in commercial HVAC you should get both low and...

    As in commercial HVAC you should get both low and liquid readings to tell what is going on. This would be helpfull along with an amp reading to help us help you.
  13. Replies
    22
    Views
    1,503

    mantiwac

    Them thar mantiwaks can be a real bar to fix on. I ain't seen one of them critters in yars and hope I nar see another un.
  14. Replies
    11
    Views
    987

    Not Optional

    Clear at least 4 hours of your day
    Clean machine properly
    Change ice thickness probe
    Set thickness to 1/4 inch (it can be fine tuned later)
    Stay there watch and record what unit does. Test coils...
  15. Replies
    15
    Views
    1,613

    May want to verify oil. 134A poe, 409A min or...

    May want to verify oil. 134A poe, 409A min or alka. I was on what data plate said was a R12 yesterday, but the compressor had poly oil in it.

    Ooops sorry just remembered it was a reach in...
  16. Thread: crushed ice

    by mdnbiker
    Replies
    3
    Views
    621

    I have to agree with both of you. No they don't...

    I have to agree with both of you. No they don't make a residential unit that I'm aware of but I have seen the scottsman undercounter flaker in many residential applications. Manitowoc makes a small...
  17. Replies
    2
    Views
    619

    To the best of my knowledge there is no fix other...

    To the best of my knowledge there is no fix other than evap replacement.
  18. Replies
    91
    Views
    6,338

    universally understood---Dads house ---Dads rules...

    universally understood---Dads house ---Dads rules

    All's well that ends well.
  19. Replies
    91
    Views
    6,338

    $116.00 Was before the Sears guy was called. ...

    $116.00 Was before the Sears guy was called. With 2 hours labor, drive time, mileage, ect. it will be closer to 300++ dollars. Repairing it myself would have been my option, but I'm not paying the...
  20. Replies
    91
    Views
    6,338

    outcome??

    just interested in finding out whether your dad has ice or still in limbo?
  21. Replies
    91
    Views
    6,338

    It looked like he was on the verge of solving the...

    It looked like he was on the verge of solving the problem. I guess a person can't make a joke about MT. Just trying to be helpfull. Do I understand you to say he doesn't need my help?
  22. Replies
    20
    Views
    1,402

    409A??????????? no oil change needed

    409A??????????? no oil change needed
  23. Replies
    91
    Views
    6,338

    Detailed proceedure removed. MT does not need my...

    Detailed proceedure removed. MT does not need my help.
  24. Replies
    6
    Views
    942

    Set ice thickness probe 3/16 to 1/4 inch from...

    Set ice thickness probe 3/16 to 1/4 inch from evap. If you set it to close it won't harvest, then you'll be thinking something is else is wrong. Full cycle time should be under 20 min. I use a...
  25. Replies
    84
    Views
    4,535

    He really does love you.............he just has a...

    He really does love you.............he just has a hard time expressing his feelings.;)